Belden

943988005

943988005 - OS30-0008021A1ATREPHH - Managed IP67 Switch, 10 ports, supply voltage 24 VDC, Software L2P
943988005
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Product description

Type
OCTOPUS OS30-0008021A1ATREPHH
Description
The OCTOPUS switches are suited for outdoor applications with rough environmental conditions. Because of the branch typical approvals they can be used in transport applications (E1), as well as in trains (EN 50155) and ships (GL).
Part Number
943988005
Port type and quantity
10 ports in total uplink ports: 1000 BASE-SX, multi mode, housing acc. ISO/IEC 24702 and IEC 63076-3-106 Version 1 8 x 10/100 BASE-TX TP-cable, auto-crossing, auto-negotiation, auto-polarity.

More Interfaces

Power supply/signaling contact
1 x M12 5-pin connector, A coding,
V.24 interface
1 x M12 4-pin connector, A coding
USB interface
1 x M12 5-pin socket, A coding

Network size - length of cable

Twisted pair (TP)
0-100 m
Multimode fiber (MM) 50/125 µm
0-550 m, 6.5 dB link budget at 850 nm, A = 3 dB/km, 3 dB reserve, B = 400 MHz*km
Multimode fiber (MM) 62.5/125 µm
0-275 m, 6.5 dB link budget at 850 nm, A = 3.2 dB/km, 3 dB reserve, B = 200 MHz*km

Network size - cascadibility

Line - / star topology
any
Ring structure (HIPER-Ring) quantity switches
50 (reconfiguration time

Power requirements

Operating Voltage
24/36 VDC -30% / +30% (16,8 ..45 VDC)
Power consumption
9 W
Power output in BTU (IT)/h
30.7
Redundancy functions
redundant power supply

Software

Management
Serial interface V.24 web-interface, Telnet, SSHv2, HTTP, HTTPS, TFTP, SFTP, SNMP v1/v2/v3, Traps
Diagnostics
LEDs (power 1, power 2, link status, data, redundancy manager, error) cable tester, signalling contact, RMON (statistics, history, alarms, events), SysLog support, port mirroring
Configuration
Command Line Interface (CLI), auto-configuration adapter, TELNET, BootP, DHCP Option 82, HiDiscovery
Security
Port Security (IP and MAC), SNMPv3, SSHv3, SNMP access settings (VLAN/IP), IEEE 802.1X authentication

Ambient conditions

MTBF (Telecordia SR-332 Issue 3) @ 25°C
41 Years
Operating temperature
-40-+70 °C
Note
Please note that some recommended accessory parts only support a temperature range from -25 ºC to +70 ºC and might limit the possible operating conditions for the entire system.
Storage/transport temperature
-40-+70 °C
Relative humidity (also condensing)
5-100 %

Mechanical construction

Dimensions (WxHxD)
261 mm x 189 mm x 53 mm
Weight
1750 g
Mounting
Wall mounting
Protection class
IP65, IP67

Mechanical stability

IEC 60068-2-6 vibration
1 mm, 2 Hz-13.2 Hz, 90 min. 0.7 g, 13.2 Hz-100 Hz, 90 min. 3.5 mm, 3 Hz-9 Hz, 10 cycles, 1 octave/min. 1 g, 9 Hz-150 Hz, 10 cycles, 1 octave/min
IEC 60068-2-27 shock
15 g, 11 ms duration, 18 shocks

EMC interference immunity

EN 61000-4-2 electrostatic discharge (ESD)
6 kV contact discharge, 8 kV air discharge
EN 61000-4-3 electromagnetic field
10 V/m (80-1000 MHz)
EN 61000-4-4 fast transients (burst)
2 kV power line, 1 kV data line
EN 61000-4-5 surge voltage
power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line
EN 61000-4-6 Conducted Immunity
3 V (10 kHz-150 kHz), 10 V (150 kHz-80 MHz)

EMC emitted immunity

EN 55032
EN 55032 Class A
FCC CFR47 Part 15
FCC 47CFR Part 15, Class A

Approvals

Basis Standard
CE, EAC, Australian Regulatory Compliance Mark (RCM)
Safety of industrial control equipment
cUL 60950
Railway norm
EN 50121-4
Transportation
E1

Scope of delivery and accessories

Accessories to Order Separately
ACA22-M12 (EEC) (942 125-001), M12 conector, "D"-coded (934 445-001) 2 m cordset with M12-connector, "D"-coded (934 578-001) 5 m cordset with M12-connectors, "D"-coded (934 578-002) 10 m cordset with M12-connectors, "D"-coded (934 578-003) Bulkhead M12 "D"-coded to RJ45 (934 498-001), OCTOPUS metal dust cover set (25 pieces) (942 057-001), OCTOPUS plastic dust cover set (25 pieces) (942 057-002)*
Scope of delivery
1 × Device, 1 x connector for power connection, General safety instructions

Further Instructions

Product Documentation
https://www.doc.hirschmann.com
Certificates
https://www.doc.hirschmann.com/certificates.html
Update and Revision
Revision Number: 0.55 Revision Date: 08-06-2021

Documents

Data Sheet

Download

Related products