CLP4MT2A230
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Environment
- Overvoltage category
- III (IEC 60664)
- Degree of protection
- IP 20 /IEC 60529, 60947-1)
- Pollution degree
- 2 (IEC 60664/60664A, 60947-1)
Rated Operational Power
- AC supply
- 5 VA
- AC/DC supply
- 5 VA / 5 W
Rated Operational Voltage (UB)
- Pin 2 & 10
- 195 to 265 VAC, 45 to 65 Hz
- Rated insulation voltage
- <2.0 kVAC (rms)
- Rated impulse withstand voltage
- 4 kV (1.2/50 µs) (line/neutral)
Relay Rating (AgCdO)
- Resistive loads AC1
- 8 A / 250 VAC (2500 VA)
- Resistive loads DC1
- 1 A / 250 VDC (250 W) or 10 A 25 VDC (250 W)
- Small induc. Loads AC11
- 0,4 A / 250 VAC
- Small induc. Loads DC13
- 0,4 A / 30 VDC
- Mechanical life (typical)
- ≥ 30 x 106 operations @ 18’000 imp/h
- Electrical life (typical) AC1
- > 250’000 operations
Specifications
- Mounting
- 11 pin circular plug
- Relay
- SPDT + SPST
- Supply
- 230 VAC
- Delay on operate (tV
- < 300 mS
- Level probe supply
- Max. 12 VAC
- Level probe current
- Max. 2.5 mA
- Sensitivity
- 220Ω to 220KΩ Factory preset: 47KΩ
- Dielectric voltage
- >2.0 KVAC (rms) (contacts / electronics)
- Rated impulse withstand volt.
- 4 kV (1.2/50 µS) (contacts / electronics) (IEC 664)
- Operating frequency (f) Relay output
- 1 HZ
- Response time
- 1 s (3,5 s with filter)
- Housing material
- NORYL SE1, light grey
- Weight
- 200 g
- Approvals
- UL508, cus
- CE marking
- Yes
Temperature
- Operating
- -20º to +50ºC (-4º to + 122ºF)
- Storage
- -50º to +85ºC (-58º to +185ºF)
Outputs
- Rated insulation voltage
- Make or break on DIP-switch 250 VAC (rms) (cont./elec.)