Specifications

Predictive maintenance
No
Time Delays
No
Rated switching distance
2000
Sensing range, maximum
2000
Output current, maximum
200
Target included
No
Analogue output 0 V ... 10 V
No
Analogue output 0 mA ... 20 mA
No
Analogue output 4 mA ... 20 mA
No
Analogue output -10 V ... +10 V
No
With other analogue output
No
Setting procedure
Manual adjustment
With communication interface analogue
No
With communication interface AS-Interface
No
With communication interface CANOpen
No
With communication interface DeviceNet
No
With communication interface Ethernet
No
With communication interface INTERBUS
No
With communication interface PROFIBUS
No
With communication interface RS-232
No
With communication interface RS-422
No
With communication interface RS-485
No
With communication interface SSD
No
With communication interface SSI
No
Number of semiconductor outputs with signalling function
2
Number of protected semiconductor outputs
2
Type of interface for safety communication
Other
Connection Type
Cable
Output type
NPN
Output function
Complementary (NO+NC)
Operation agent-safety class
Safety class 0
Housing style
Cylindrical, threaded barrel
Diameter
18
Length
55
Sensing mode
Light-/dark switching
Material of optical surface
Plastic
Housing Material
Metal
Output current, maximum at protected output
200
Min. reflector distance
200
Ambient temperature
Min.-20-Max.60
Time of reaction
3.2
Switching frequency
100
Type of safety acc. IEC 61496-1
1
Switching voltage of OSSD at state "high"
40
Rated Operetional voltage UB at DC
Min.10-Max.40
Voltage type
DC
With monitoring function downstream switching devices
No
Wavelength of the sensor
660
Type of light
Polarized red light
Light dot size
17665
With restart blockage
No
Suitable for safety functions
No
Degree of protection
IP67
Degree of protection (NEMA)
1
With approval according to UL
Yes
Rail mounting possible
No
Wall mounting/direct mounting
No
ECOLAB approved
No
Housing material, specific
NPB
Degree of protection (IP)
IP67
Degree of protection (NEMA)
1, 2, 12
IO-Link
No
Item Code 1
AMB18-A | AMB18-A316L | AMB18-S | AMB18-S316L
Product Main Family
Sensors
Product Main Family Group
Photoelectric sensors

Documents

Data Sheet

Download

Related products