3NC2263
SITOR CYL FUSE AR 63 A,660V AC/700V DC SITOR CYLINDRICAL FUSE LINK AR 63 A, 660 V AC/700 V DC
SITOR CYL FUSE AR 63 A,660V AC/700V DC SITOR CYLINDRICAL FUSE LINK AR 63 A, 660 V AC/700 V DC
- New Factory Sealed123 pcs.
- New Surplus20 pcs.
Filters
SITOR CYL FUSE AR 63 A,660V AC/700V DC SITOR CYLINDRICAL FUSE LINK AR 63 A, 660 V AC/700 V DC
SITOR CYL FUSE AR 63 A,660V AC/700V DC SITOR CYLINDRICAL FUSE LINK AR 63 A, 660 V AC/700 V DC
SITOR SET FUSES, 800A, 500VAC, CLASS GR
SITOR SET FUSES, 800A, 500VAC, CLASS GR
SITOR FUSE-LINK 25A,AC 660V (DIN 43620, SIZE 00) SITOR FUSE LINKS 25A, AC 690V
SITOR FUSE-LINK 25A,AC 660V (DIN 43620, SIZE 00) SITOR FUSE LINKS 25A, AC 690V
Mersen aM and gG fuse-links cover a wide range of physical sizes and ampere ratings for 400, 500, and 690VAC for protection in electrical distribution circuits and various industrial applications. Most ratings are available in size 8x31 and size 10x38 with an optional indicator, and in size 14x51 and 22x58 with an optional striker to activate an auxiliary contact. All cylindrical fuse-links have ceramic bodies and silver-plated ferrules. Cylindrical fuse-links gG are used for the protection of cables, motors and LV-networks. They limit and cut off unacceptable overcurrents and short-circuit currents up to their nominal breaking capacity. Cylindrical fuse-links gG also protect electrical equipment and installations against the dynamic effect of high short-currents. Our technology and process was designed to ensure highly reliable technical performance.
Mersen aM and gG fuse-links cover a wide range of physical sizes and ampere ratings for 400, 500, and 690VAC for protection in electrical distribution circuits and various industrial applications. Most ratings are available in size 8x31 and size 10x38 with an optional indicator, and in size 14x51 and 22x58 with an optional striker to activate an auxiliary contact. All cylindrical fuse-links have ceramic bodies and silver-plated ferrules. Cylindrical fuse-links gG are used for the protection of cables, motors and LV-networks. They limit and cut off unacceptable overcurrents and short-circuit currents up to their nominal breaking capacity. Cylindrical fuse-links gG also protect electrical equipment and installations against the dynamic effect of high short-currents. Our technology and process was designed to ensure highly reliable technical performance.
The NH system is classified among plug-in fuse systems and is composed of: fuse-base, (possibly including terminal covers and phase barriers) fuse-link with blade contact fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current, it must be handled by a qualified professional.
The NH system is classified among plug-in fuse systems and is composed of: fuse-base, (possibly including terminal covers and phase barriers) fuse-link with blade contact fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current, it must be handled by a qualified professional.
FUSE LINK, SITOR, 5A, 660V AC, 14 X 51MM SITOR CYLINDRICAL FUSE LINK AR 5 A, 660 V AC/700 V DC
FUSE LINK, SITOR, 5A, 660V AC, 14 X 51MM SITOR CYLINDRICAL FUSE LINK AR 5 A, 660 V AC/700 V DC
Engineered to protect photovoltaic applications Mersen's HP10M photovoltaic (PV) fuse series was engineered and designed specifically for the protection of photovoltaic systems. Its enhanced fuse construction makes it ideal for constant temperature and current cycling withstand adding to system longevity. The 1000VDC rated HP10M, designed for low minimum breaking capacity capabilities of 1.35 times the fuse rated current value, allows for safe circuit interruption under typical low fault current conditions produced by PV arrays. Protect your off-grid or grid tied PV system from unexpected ground faults and line faults using Mersen's HelioProtection fuse line.
Engineered to protect photovoltaic applications Mersen's HP10M photovoltaic (PV) fuse series was engineered and designed specifically for the protection of photovoltaic systems. Its enhanced fuse construction makes it ideal for constant temperature and current cycling withstand adding to system longevity. The 1000VDC rated HP10M, designed for low minimum breaking capacity capabilities of 1.35 times the fuse rated current value, allows for safe circuit interruption under typical low fault current conditions produced by PV arrays. Protect your off-grid or grid tied PV system from unexpected ground faults and line faults using Mersen's HelioProtection fuse line.
FUSE-LINK SITOR 63A,AC 1000V 63A,AC 1000V (DIN 43620,SIZE 0) SITOR FUSE-LINK
FUSE-LINK SITOR 63A,AC 1000V 63A,AC 1000V (DIN 43620,SIZE 0) SITOR FUSE-LINK
This is a NFC fuse cartridge for TeSys GS switch-disconnector fuses devices. It is a gG fuse-link that protects against thermal overloads and magnetic over currents, used in standard applications. Its current rating is 20 A and the maximum rated voltage is 500 VAC. It is a cylindrical fuse (NFC type), the dimensions are 10mm x 38mm. It has no striker to indicate when the fuse is blown. This fuse is sold by set of 10 parts.
This is a NFC fuse cartridge for TeSys GS switch-disconnector fuses devices. It is a gG fuse-link that protects against thermal overloads and magnetic over currents, used in standard applications. Its current rating is 20 A and the maximum rated voltage is 500 VAC. It is a cylindrical fuse (NFC type), the dimensions are 10mm x 38mm. It has no striker to indicate when the fuse is blown. This fuse is sold by set of 10 parts.
FUSE,50A,AC,690V,(GR.000) 50A , AC 690 V ,(SIZE 000) UTILIZ. CATEGORY GR, DIN 43620 SITOR FUSE-LINK
FUSE,50A,AC,690V,(GR.000) 50A , AC 690 V ,(SIZE 000) UTILIZ. CATEGORY GR, DIN 43620 SITOR FUSE-LINK
FUSE LINK,LV HRC,315A,SZ3 SIZE 3, 315A, AC 500V/DC 440V WITH FRONT INDICATOR WITH NON-INSULATED GRIP LUGS LV HRC FUSE LINK GL/GG
FUSE LINK,LV HRC,315A,SZ3 SIZE 3, 315A, AC 500V/DC 440V WITH FRONT INDICATOR WITH NON-INSULATED GRIP LUGS LV HRC FUSE LINK GL/GG
FUSE,LV HRC,25A,500V,SIZE 000 SIZE 000, 25A, AC 500V/DC 250V WITH COMBINATION INDICATOR WITH INSULATED GRIP LUGS LV HRC FUSE LINK GL/GG
FUSE,LV HRC,25A,500V,SIZE 000 SIZE 000, 25A, AC 500V/DC 250V WITH COMBINATION INDICATOR WITH INSULATED GRIP LUGS LV HRC FUSE LINK GL/GG
Switch Fuses,Front Operated,4-pole,03 (Left Side),DIN,0,1,Handle and shaft included,Detachable Neutral Link Integrated Into the Mechanism
Switch Fuses,Front Operated,4-pole,03 (Left Side),DIN,0,1,Handle and shaft included,Detachable Neutral Link Integrated Into the Mechanism
The OSD100M125, manufactured by Eaton, is a highly efficient and reliable industrial automation product. This component is designed to provide advanced monitoring and control capabilities to modern manufacturing facilities. With a compact and robust design, the OSD100M125 is equipped with a range of features, including high-speed data communication, precision control, and real-time monitoring. The component is easy to install and integrate, and it can be customized to meet the unique needs of any industrial application. Whether you are looking to improve efficiency, reduce downtime, or enhance quality control, the OSD100M125 can deliver the performance and reliability you need. Trust Eaton to provide you with the industrial automation solutions you need to succeed.
The OSD100M125, manufactured by Eaton, is a highly efficient and reliable industrial automation product. This component is designed to provide advanced monitoring and control capabilities to modern manufacturing facilities. With a compact and robust design, the OSD100M125 is equipped with a range of features, including high-speed data communication, precision control, and real-time monitoring. The component is easy to install and integrate, and it can be customized to meet the unique needs of any industrial application. Whether you are looking to improve efficiency, reduce downtime, or enhance quality control, the OSD100M125 can deliver the performance and reliability you need. Trust Eaton to provide you with the industrial automation solutions you need to succeed.
FUSE,LV HRC,50A,500VAC,SIZE 000 SIZE 000, 50A, AC 500V/DC 250V WITH COMBINATION INDICATOR WITH NON-INSULATED GRIP LUGS LV HRC FUSE LINK GL/GG
FUSE,LV HRC,50A,500VAC,SIZE 000 SIZE 000, 50A, AC 500V/DC 250V WITH COMBINATION INDICATOR WITH NON-INSULATED GRIP LUGS LV HRC FUSE LINK GL/GG