Loss/Length Specifications

Testing Speeds (excludes referencing times)
Far End Source mode: ≤ 2 seconds (2 wavelengths, one direction auto wavelength detection) || Smart Remote mode: < 3 seconds (2 wavelengths, one direction, auto wavelength detection) || Loopback mode: ≤ 2 seconds (2 wavelengths, one direction auto wavelength detection)
Input/Output Connectors
Interchangeable connector adapter (LC standard, SC, ST and FC optional)
Launch Condition1,2
Encircled Flux compliant to TIA-526-14-B, ISO/IEC 14763-3 and IEC 61280-4-1
Fiber Types Tested
50/125 µm or 62. 5/125 µm || singlemode
Source Type and Wavelengths
LED source 850 nm ± 30 nm 1300 nm ± 20 nm || Fabry-Perot laser diode 1310 nm ± 20 nm 1550 nm ± 30 nm
Maximum Length Measurement
12 km || 130 km
Length Measurement Accuracy
± 1. 5 m plus ± 1 % of length
Output Power (Nominal)
≥ -24 dBm with EF-TRC || ≥ -4 dBm
Output Power Stability3
± 0. 1 dB over 8 hours ± 0. 08 dB over 15 minutes || ± 0. 05 dB over 8 hours ± 0. 03 dB over 15 minutes

Selected Specifications

Output Power
>-5 dBm<0 dBmSMF-28 singlemode fiberContinuous waveSC/UPC connector
Operating Wavelength
650 nm nominal
Output Modes
Pulsed mode (2 Hz to 3 Hz blink frequency) || Continuous wave
Connector Adapter
2. 5 mm universal
Laser Safety
Over operating temperature range || Class II CDRH

Power Meter Specifications

Input Connector
Interchangeable connector adapter (LC standard, SC, ST and FC optional)
Detector Type
InGaAs
Wavelengths
850 nm, 1300 nm, 1310 nm, 1550 nm
Power Measurement Range
0 dBm to -65 dBm (850 nm) 0 dBm to -70 dBm (all other wavelengths)
Power Measurement Uncertainty1,2
< +/- 5% +/- 32 pW
Measurement Linearity3
< ± 0. 1 dB
Re-calibration Period
1 year
Integrated Wi-Fi
Meets IEEE 802. 11 a/b/g/n; dual band (2. 4 GHz and 5 GHz)

Loss/Length Specifications (continued)

Source Wavelengths
850 nm, 1300 nm, 1310 nm, 1550 nm
Power Measurement Range
0 dBm to -65 dBm (850 nm) 0 dBm to -70 dBm (all other wavelengths)
Power Measurement Uncertainty1, 2
< +/- 5% +/- 32 pW
Measurement Linearity3
< ± 0. 1 dB
Re-calibration Period
1 year

Environmental Specifications

Operating Temperature
-10° C to 45° C
Storage Temperature
-10° C to +60° C
Operating Relative Humidity % RH without condensation
% RH without condensation || 0 % to 90 %, 32 °F to 95 °F (0° C to 35° C) || 0 % to 70 %, 95 °F to 113 °F (35° C to 45° C)
Vibration
Random, 2 g, 5 Hz-500 Hz
Shock
1 m drop test with and without module and adapters
Safety
CSA C22. 2 No. 1010. 1: 1992 || EN 61010-1 1st Edition + Amendments 1, 2
Pollution Degree
2
Altitude
Operating: 4,000 m; storage: 12,000 m
EMC
EN 61326–1