Fluke Networks

OFP2-100-S-NW

OptiFiber® Pro OTDR Family
OFP2-100-S-NW
OFP2-100-S-NW
OFP2-100-S-NW
OFP2-100-S-NW
OFP2-100-S-NW
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Key OptiFiber Pro HDR Specification

Wavelengths
1490 nm +/- 20 nm || 1550 nm +/- 20 nm || 1310 nm +/- 25 nm || 1625 nm +/- 20 nm
Compatible fiber types
Singlemode
OTDR Port Connector
Cleanable APC ferrule with removable SC adapter
Event dead zone 1
0. 7 m (typical)
Attenuation dead zone2
4m (typical)
PON dead zone3
30 m (typical)
Max distance range setting
260 km
Dynamic range 4, 5
1310 nm: 42 dB (typical || 1490 nm: 41 dB (typical) || 1625 nm: 40 dB (typical) || 1550 nm: 41 dB (typical) || 1310 nm: 42 dB (typical)
Reflectance range4
-14 to -70 dB (typical)
Sampling resolution
3 cm to 2 m
Sampling points
Up to 129000
Pulse widths (nominal)
5, 10, 30, 50, 100, 300, 500, 1000, 3000, 5000, 10000, 20000 ns
Distance uncertainty
+/-(1 + 0. 0005*distance + 0. 5*resolution)
Linearity
± 0. 03 dB/dB
Reflectance uncertainty
±2 dB
Test Time (per wavelength)
Best resolution setting: 5 to 180 seconds/wavelength || Auto PON setting: 10 seconds/wavelength (typical) || Quick test setting: 3 seconds/wavelength (typical) || Manual PON setting: 3, 5, 10, 20, 40, 60, 90, 120, 180 seconds/wavelength || Manual setting: 3, 5, 10, 20, 40, 60, 90, 120, 180 seconds/wavelength || Auto setting: 5 seconds/wavelength (typical)
Laser Classification
Class 1 CDRH Complies to EN 60825-2, 3rd Edition
Calibration Period
1 year

Additional key specifications

Magnification
~ 200X with OptiFiber Pro Display
Light source
Blue LED
Power source
Versiv mainframe
Field of View (FOV)
Horizontal: 425 µm || Vertical: 320 µm
Minimum detectable particle size
0. 5 µm
Dimensions
Mainframe with module and battery: 2. 625 in x 5. 25 in x 11. 0 in ( 6. 67 cm x 13. 33 cm x 27. 94 cm)
Weight
Mainframe with module and battery: 3 lbs, 5 oz (1. 28 kg)
Temperature range
Operating: 32°F to 122°F (0 °C to +50 °C) || Storage: -4°F to +158°F (-20°C to +70°C)
Certifications
CE (when used with the mainframe)
On/Off control
Mechanical switch and a button on the touch screen
Output power
316 µW (-5 dBm) = peak power = 1. 0 mW (0 dBm)
Operating wavelength
650 nm nominal
Spectral width (RMS)
±3 nm
Output modes
Continuous wave Pulsed mode (2 Hz to 3 Hz blink frequency)
Connector adapter
2. 5 mm universal
Laser safety (classification)
Class II CDRH Complies to EN 60825-2
Battery
Lithium ion battery pack, 7. 2 volts
Battery life
Eight hour Auto OTDR operation, dual wavelength, no video probe connected, 150 m of fiber
Integrated Wi-Fi
Meets IEEE 802. 11 a/b/g/n; dual band (2. 4 GHz and 5 GHz)
Tester Off
Four hours to charge from 10% to 90% capacity
Tester On
Six hours to charge from 10% to 90% capacity with the tester on
Operating temperature*
-10ºC to 45ºC
Storage Temperature
-10ºC to +60ºC
Operating altitude
4,000 m (13123 ft) || 3200 m (10,500 ft) with ac adapter
Storage altitude
12,000 m
EMC
EN 61326-1

Key OptiFiber Pro OTDR specifications

Wavelengths
850 nm +/- 10 nm || 1300 nm +35/-15 nm || 1550 nm +/- 30 nm || 1310 nm +/- 25 nm
Compatible fiber types
50/125 µm || 62. 5/125 µm || Singlemode
Event dead zone 1
1550 nm: 0. 6 m typical || 1310 nm: 0. 6 m typical || 850 nm: 0. 5 m typical || 1300 nm: 0. 7 m typical
Attenuation dead zone 2
1310 nm: 3. 6 m typical || 1300 nm: 4. 5 m typical || 850 nm: 2. 5 m typical || 1550 nm: 3. 7 m typical
Dynamic range 3, 5, 6
1300 nm: 30 dB typical || 850 nm: 28 dB typical || 1550 nm: 30 dB typical || 1310 nm: 32 dB typical
Max distance range setting
40 km || MM: 40 km || SM: 130 km || 130 km
Distance measurement range 4, 5, 7, 8, 9, 10
1310 nm: 80 km || 850 nm: 9 km || 1550 nm: 130 km || 1300 nm: 35 km
Reflectance range 4, 5
1300 nm: -14 dB to -62 dB (typical) || 1310 nm: -14 dB to -65 dB (typical) || 1310 nm: -14 dB to -65dB (typical) || 1550 nm: -14 dB to -65 dB (typical) || 850 nm: -14 dB to -57 dB (typical)
Sample resolution
3 cm to 400 cm
Pulse widths (nominal)
1300 nm: 3, 5, 20, 40, 200, 1000 ns || 1310/1550 nm: 3, 10, 30, 100, 300, 1000, 3000, 10000, 20000 ns || 850 nm: 3, 5, 20, 40, 200 ns
Test time (per wavelength)
|| Best resolution setting: 5 to 180 sec || Manual setting: 3, 5, 10, 20, 40, 60, 90, 120, 180 sec || Auto setting: 10 sec (typical) || Quick test setting: 2 sec (typical) || MM - 2 sec (typical), MM - 180 sec (max) || Manual setting: || -3, 5, 10, 20, 40, 60, 90, 120, 180 sec SM - 3, 5, 10, 20, 40, 60, 90, 120, 180 sec || DataCenter OTDR setting: 1 sec (typical at 850 nm), 7 sec (max) || DataCenter OTDR setting: || SM - 10 sec (typical), SM - 180 sec (max) || Auto setting: 5 sec (typical) || FaultMap setting: 10 sec (typical), 180 sec (max) || FaultMap setting: || Best resolution setting: 2 to 180 sec || MM – 1 sec (typical at 850 nm) MM – 7 sec (max) || MM – 2 sec (typical) || Quick test setting: || DataCenter OTDR setting: 20 sec (typical), 40 sec (max) || MM – 2 to 180 sec M || SM – 10 sec (typical) || SM – 5 sec (typical) || FaultMap setting: 2 sec (typical), 180 sec (max) || Quick test setting: 5 sec (typical) || MM – 5 sec (typical) || SM – 5 to 180 sec || Best resolution setting: || SM – 20 sec (typical) SM – 40 sec (max) || Auto setting: