Environmental and mechanical

Operating temperature
0 °C to 40 °C
Storage temperature
-20 °C to 60 °C
Relative humidity
95% (10 to 35 °C)
Vibration
Random, 2g, 5-500 Hz
Shock
1 m drop onto all corners and face
Altitude
3000 m

General

Dimensions
157 x 52 x 37 mm (6. 2 x 2. 0 x 1. 3 inch)
Weight (including batteries)
0. 18 kg (5. 7 oz)
Adapter
2. 5 mm universal
Adapter cap
Tethered protective end cap
Controls
On/off, continuous/flashing
Battery type
2 x AA
Battery life
> 80 hours in continuous mode
Safety
CSA C22. 2 No. 1010. 1 1992, EN 61010-1, CE
Carrying Case
Soft sided with belt loop

Optical

Fiber compatibility
Multimode and Singlemode
Wavelength
650 nm (visible wavelength)
Laser safety rating
Class II
Output power
< 1. 3 mW
Output modes
Continuous (steady) and flashing (2-3Hz pulsed)
Range
3 km multimode, 4 km singlemode