Meter Readings

Recorded Time Span
2 weeks
Maximum number of events
1024
Record Size (min, max, average)
2 M readings for 1 channel
Measurement Speed
Maximum 2 measurement/s

Power (125B only)

Full scale reading
999 counts
Full scale reading
999 counts
Full scale reading
999 counts
Power factor (PF)
Ratio between watts and VA range - 0.00 to 1.00
Configurations
1 phase / 3 phase 3 conductor balanced loads (3 phase: fundamental component only, AUTOSET mode only)
Watt
RMS reading of multiplying corresponding samples of input A (volts) and input B (amperes)
VA reactive (var)
√((VA)2-W2)
VA
Vrms x Arms

Crest factor (CREST)

Range
1 to 10
Full scale reading
90 Counts

Waveform Record

Recorded Time Span SD card
11 hours at 500 μs/div 14 days at 20 ms/div
Size Internal memory
400 M samples Recorded Time
Span internal memory
15 minutes at 500 μs/div 11 hours at 20 ms/div
Maximum number of events
64
Record Size SD card
1.5 G samples
Maximum sample rate
400 K sample/s

Decibel (dB)

Full scale reading
1000 counts
DB on
V dc, V ac, or Vac+dc
0 dBm (600 Ω /50 Ω)
1 mW referenced to 600 Ω or 50 Ω
0 dBV
1 V

Advanced Meter Functions

Fixed decimal point
Activated by using attenuation keys
Zero Set
Set actual value to reference
AutoHold (on A)
Captures and freezes a stable measurement result. Beeps when stable. AutoHold works on the main meter reading, with thresholds of 1 Vpp for AC signals and 100 mV for DC signals.

Pulse width (PULSE)

Full scale reading
1000 counts
Frequency range
15 Hz (1 Hz) to 30 MHz in continuous autoset

Input A and Input B

Accuracy
±(0.5% +5 counts)
Full scale reading
5000 counts
Ranges
500 mV, 5 V, 50 V, 500 V, 750 V
Common mode rejection (CMRR)
>100 dB @ dc, >60 dB @ 50, 60, or 400 Hz

Phase

Resolution
1 degree
Range
0 to 359 degrees
Modes
A to B, B to A

Continuity (Cont)

Detection of shorts of
≥1 ms
Beep
<(30 Ω ±5 Ω) in 50 Ω range
Measurement current
0.5 mA

Capacitance (CAP)

Measurement current
500 nA to 0.5 mA, increases with increasing ranges
Ranges
50 nF, 500 nF, 5 μF, 50 μF, 500 μF
Full scale reading
5000 counts

Frequency (Hz)

Ranges
123B: 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz,1 MHz, 10 MHz, and 50 MHz
Ranges
124B and 125B: 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz, 1 MHz, 10 MHz, and 70 MHz
Full scale reading
10,000 counts
Frequency range
15 Hz (1 Hz) to 50 MHz in continuous autoset
Accuracy @1 Hz to 1 MHz
±(0.5% +2 counts)

Cursor Readout (124B and 125B)

Single vertical line
Min, max and time from start of readout (in RECORDER mode; instrument in HOLD)
Dual vertical lines
Average, min, max and time distance readout (in ROLL mode; instrument in HOLD)
Accuracy
As oscilloscope accuracy
Dual vertical lines
Peak-peak, time distance and reciprocal time distance readout
Rise or fall time
Transition time, 0%-level and 100%-level readout (manual or auto leveling; auto leveling only  possible in single channel mode)
Dual horizontal lines
High, low and peak-peak readout
Single vertical line
Average, min and max readout
Sources
A, B
Single vertical line
Harmonics values in POWER QUALITY mode.
Single vertical line
Average, min, max and time from start of readout (in ROLL mode; instrument in HOLD)

RPM

Max reading
50.00 kRPM
Accuracy
±(0.5% +2 counts)

Duty cycle (PULSE)

Range
2% to 98%
Frequency range
15 Hz (1 Hz) to 30 MHz in continuous autoset

Temperature (TEMP) with optional temperature probe

Scale factor
1 mV/°C and 1 mV/°F
Range
200 °C/div (200 °F/div)
Accuracy
As V dc (add temp. probe uncertainty)

Vpwm

Principle
Readings show the effective voltage based on the average value of samples over a whole number of periods of the fundamental frequency
Purpose
To measure on pulse width modulated signals, like motor drive inverter outputs
Accuracy
As Vrms for sinewave signals