Combine the functions of a power analyzer, power quality logger, scope, data logger, and clamp meter, for monitoring and troubleshooting electrical loads
345
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Features

AC/DC current:
Clamp-on measurement of ac current up to 1400 A rms and dc current up to 2000 A without breaking the circuit
Highest safety rating:
600 V CAT IV power analyzer is rated for use at the service entrance
Accurate in noisy environments:
Clamp meter performs even with distorted waveforms present on electronic
Data logging:
Identify intermittent faults by logging any power quality parameter for minutes, or over a month, including harmonics
Verify batteries:
Direct measurement of dc ripple (%) for battery and dc systems
Troubleshoot harmonics:
Analyze and log harmonics digitally or graphically
Inrush current:
Capture and analyze nuisance tripping, from 3 seconds to 300 seconds
Easy to use:
Easily confirm power meter setup with large backlit color display of waveforms and trends
USB download:
Download logged data with PowerLog application software to view trends and screenshots, analyze and create reports simply.
Battery eliminator:
powers the instrument when pefroming extended logging sessions.
3-Phase power:
Built in capability for balanced loads
View graphs and generate reports:
Use power analyzer with included Power Log software

Logging Memory

Averaging periods
1 s, 2 s, 5 s, 10 s, 30 s, 1 min, 5 min, 10 min, 15 min, and custom
Logging areas
Three areas that can be used individually or combined into one large area

Interface

USB Interface to a PC
Power Log software for download, analysis and reporting 345 Upgrade Utility for installing a new firmware version

Ambient Conditions (For Indoor Use Only)

Reference conditions
All accuracies stated at 23°C ±1°C (73.4°F ±1.8°F)
Temperature coefficient of voltage
≤ ±0.15% of rdg per °C
Maximum relative humidity
80% for temperatures up to 31°C (87°F) decreasing linearly to 50% relative humidity at 40°C (104°F)
Operating temperature
0°C to 50°C (32°F to 122°F)
Maximum operating altitude
2000 m
Temperature coefficient of current
≤ ±0.15% of rdg per °C

Frequency Measurement (From Current Or Voltage Sources)

Resolution
0.1 Hz
Current range
10 A to 1400 A rms
Measuring range
15 Hz to 1 kHz
Voltage range
1 V to 825 V rms
Accuracy
15 to 22 Hz ±0.5% rdg 40 Hz to 70 Hz ±0.5% rdg 15 Hz to 1000 Hz ±1% rdg

Electrical Data

Accuracy
23°C ±1°C (73.4°F ±1.8°F). See Ambient conditions specifications for temperature coefficients.

Displacement Power Factor (Single- and Three-Phase)

Resolution
0.001
Frequency range
15 Hz to 22 Hz and 45 Hz to 65 Hz
Accuracy
±3°
Measuring range
0.3 capacitive to 1.0 and 1.0 to 0.3 inductive (72.5° capacitive to 0° and 0° to 72.5° inductive)

Power factor (single- and three-phase)

Accuracy
±3°
Resolution
0.001
Frequency range
15 Hz to 1 kHz
Measuring range
0.3 capacitive to 1.0 and 1.0 to 0.3 inductive (72.5° capacitive to 0° and 0° to 72.5° inductive)

Mechanical

Jaw capacity
58 mm diameter
Cleaning
The unit can be cleaned with an Isopropanol impregnated cloth. Do not use abrasives or other solvents.
Dimensions (L x W x D)
300 x 98 x 52 mm (12 x 3.75 x 2 in)
Jaw opening
60 mm
Weight including batteries
820 g (1.8 lb)

AC and DC Current and Voltage Measurement – Ideal Tool For Troubleshooting and Logging On Power Electronics

Setup and troubleshoot variable frequency drives and UPS systems
Verify correct operation by measuring key power quality parameters
Harmonics measurements
Uncover harmonic issues that can damage or disrupt critical equipment
Inrush capture
Check start-up current where spurious resets or nuisance circuit breaker tripping occurs
Load studies
Verify electrical system capacity before adding loads

Electrical Safety

Voltage measurement
600 VAC rms or DC between either input terminal and ground, or 825 V between energized phase voltages (delta power config.)
Maximum safe working voltages
Safety IEC 61010-1 600 V CAT IV double or reinforced insulation, pollution degree 2 Protection IP40; EN60529
Current measurement
600 VAC rms or DC between uninsulated conductor and ground

Watts measurement (single and three-phase) (DC, DC rms, AC rms)

Measuring range
0 to 1650 kW DC or 1200 kW AC
Resolution
1 W in 4 kW 10 W in 40 kW 100 W in 400 kW 1 kW in 1200 kW
Accuracy
2.5% rdg ±5 digits W1Ø < 2 kW ±0.08 kW W3Ø < 4 kW ±0.25 kW
Measuring range
4 kW, 40 kW, 400 kW, 1650 kW

EMC

Emission
IEC/EN 61326-1:1997 A
Immunity
IEC/EN 61326-1:1997 Annex C Performance Criterion B