Fluke
414D
The Fluke 414D laser distance meter – measures up to 50 meters (165 ft). Fast & easy to use, improves accuracy, reduces measurement errors. Saving time & money.
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Distance Measurement
- Typical measuring tolerance 1
- ±2.0 mm 3
- Maximum measuring tolerance 2
- ±3.0 mm 3
- Typical range 1
- 40 m / 130 ft
- Smallest unit displayed
- 1 mm / 1/16 in
- Ø Laser point at distances
- 6 / 30 / 60 mm (10 / 50 / 100 m)
- Range at unfavorable condition 4
- 35 m / 115 ft
- Range At Leica Target Plate GZM26
- 50 m / 165 ft
General
- EMC
- EN 61000-4-3:2010
- Laser class
- 2
- EMC
- EN 55022:2010
- Battery life (2 x AAA) 1.5 V NEDA 24A/IEC LR03
- Up to 3,000 measurements
- Automatic laser off
- After 90 seconds
- Maximum altitude
- 3000 m
- Safety
- IEC Standard No. 61010-1:2001
- Calibration cycle
- Not applicable
- Automatic power off
- After 180 seconds
- Maximum relative humidity
- 85% at 20°F to 120°F (-7°C to 50°C)
- Temperature rangeStorage operation
- -25°C to +70°C (-13°F to +158°F)
- Temperature rangeStorage operation
- 0°C to +40°C (32°F to +104°F)
- Size (L x W x D)
- 116 x 53 x 33 mm
- Laser type
- 635 nm, < 1 mW
- Weight (with batteries)
- 113 g
- EMC
- EN 61000-4-8:2010
- EMC
- 1. Applies for 100% target reflectivity (white painted wall), low background illumination, 25°C. 2. Applies for 10 to 500% target reflectivity, high background illumination, -10°C to +50°C. 3. Tolerances apply from 0.05 m to 10 m with a confidence level of 95%. The maximum tolerance may deteriorate to 0.1 mm/m between 10 m to 30 m and to 0.15 mm/m for distances above 30 m. 4. Applies for 100% target reflectivity, background illumination between 10'000 lux and 30'000 lux. 5. After user calibration. Additional angle related deviation of ±0.01° per degree up to ±45° in each quadrant. Applies at room temperature. For the whole operating temperature range the maximum deviation increases by ±0.1°.
- Safety
- EN60825-1:2007 (Class II)
- Protection class
- IP40
Tilt Measurement
- Range
- No
- Measuring tolerance to laser beam 5
- No
- Measuring tolerance to housing 5
- No
Other Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther