Fluke

9144-A-156

The 9144 Series Field Metrology Wells extend high performance to the industrial process environment by maximizing portability, speed, and functionality with little compromise to metrology performance.
9144-A-156
9144-A-156
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

P Specifications

Reference resistance accuracy2
0 ohms to 42 ohms: ±0.0025 ohms 42 ohms to 400 ohms: ±60 ppm of reading
RTD resistance accuracy2
25 ohms to 400 ohms: ±80 ppm of reading 0 ohms to 25 ohms: ±0.002 ohms
RTD characterizations
PT-100 (385),(JIS),(3926), NI-120, Resistance
Built-in RTD thermometer readout accuracy
NI-120: ±0.015°C at 0°C PT-100 (385): ±0.02°C at 0°C PT-100 (3926): ±0.02°C at 0°C PT-100 (JIS): ±0.02°C at 0°C
Reference probe connection
6-pin Din with Infocon Technology
Internal cold junction compensation accuracy
±0.35°C (ambient of 13°C to 33°C)
TC millivolt range
–10 mV to 75 mV
Loop power function
24 V DC loop power
Reference resistance range
0 ohms to 400 ohms
MA range
Cal 4-22 mA, Spec 4-24 mA
RTD connection
4 terminal input
Reference measurement capability
4-wire
Built-in reference thermometer readout accuracy (4-wire reference probe)1
±0.010°C at -25°C ±0.015°C at 0°C ±0.020°C at 50°C ±0.025°C at 150°C ±0.030°C at 200°C ±0.040°C at 350°C ±0.050°C at 420°C ±0.070°C at 660°C
MA connection
2 terminal input
RTD resistance range
0 ohms to 400 ohms
Built-in electronics temperature Coefficient (0°C to 13°C, 33°C to 50°C)
1. The temperature range may be limited by the reference probe connected to the readout. The Built-In Reference Thermometer Readout Accuracy does not include the sensor probe accuracy. It does not include the probe uncertainty or probe characterization errors. 2. Measurement accuracy specifications apply within the operating range and assume 4-wires for PRTs. With 3-wire RTDs add 0.05 ohms to the measurement accuracy plus the maximum possible difference between the resistances of the lead wires.
Reference characterizations
ITS-90, CVD, IEC-751, Resistance
Built-in mA readout accuracy
0.02% of reading + 2 mV
Built-in TC thermometer readout accuracy
Type J: ±0.7°C at 660°C Type K: ±0.8°C at 660°C Type T: ±0.8°C at 400°C Type E: ±0.7°C at 660°C Type R: ±1.4°C at 660°C Type S: ±1.5°C at 660°C Type M: ±1.4°C at 660°C Type L: ±0.7°C at 660°C Type U: ±0.75°C at 600°C Type N: ±0.9°C at 660°C Type C: ±1.1°C at 660°C
Built-in electronics temperature Coefficient (0°C to 13°C, 33°C to 50°C)
±0.005% of range per°C
Voltage accuracy
0.025% of reading + 0.01 mV
TC connection
Small connectors
RTD measurement capability
4-wire RTD (2-,3-wire RTD w/ Jumpers only)

Base Unit Specifications

Axial uniformity at 40 mm (1.6 in)
±0.05°C at 50°C ±0.35°C at 420°C±0.5°C at 660°C
Environmental conditions (for all specifications except temperature range)
13°C to 33°C
Temperature range at 23°C
50°C to 660°C (122°F to 1220°F)
Hysteresis
0.1
Computer interface
RS-232 and 9930 Interface-it control software included
Insert OD
24.4 mm (0.96 in)
Loading effect (with a 6.35 mm reference probe and three 6.35 mm probes)
±0.015°C at 50°C ±0.025°C at 420°C ±0.035°C at 660°C
Radial uniformity
±0.02°C at 50°C ±0.05°C at 420°C±0.10°C at 660°C
Stability
±0.03°C at 50°C ±0.04°C at 420°C±0.05°C at 660°C
Display
LCD, °C or °F user-selectable
Power requirements
100 V to 115 V (±10%), 50/60 Hz, 1400 W 230 V (±10%), 50/60 Hz, 1800 W
Heating time
15 min: 50°C to 660°C
Display accuracy
±0.35°C at 50°C ±0.35°C at 420°C ±0.5°C at 660°C
Size (H x W x D)
290 x 185 x 295 mm (11.4 x 7.3 x 11.6 in)
Cooling time
25 min: 660°C to 100°C 35 min: 660°C to 50°C
Resolution
0.01°
Immersion (well) depth
150 mm (5.9 in)
Weight
7.7 kg (17 lb)
Operating conditions
0°C to 50°C, 0% to 90% RH (non-condensing)