Fluke

9144-DW-156

The 9144 Series Field Metrology Wells extend high performance to the industrial process environment by maximizing portability, speed, and functionality with little compromise to metrology performance.
9144-DW-156
9144-DW-156
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

P Specifications

Reference resistance range
0 ohms to 400 ohms
Internal cold junction compensation accuracy
±0.35°C (ambient of 13°C to 33°C)
MA range
Cal 4-22 mA, Spec 4-24 mA
Built-in electronics temperature Coefficient (0°C to 13°C, 33°C to 50°C)
1. The temperature range may be limited by the reference probe connected to the readout. The Built-In Reference Thermometer Readout Accuracy does not include the sensor probe accuracy. It does not include the probe uncertainty or probe characterization errors. 2. Measurement accuracy specifications apply within the operating range and assume 4-wires for PRTs. With 3-wire RTDs add 0.05 ohms to the measurement accuracy plus the maximum possible difference between the resistances of the lead wires.
MA connection
2 terminal input
Loop power function
24 V DC loop power
Built-in TC thermometer readout accuracy
Type J: ±0.7°C at 660°C Type K: ±0.8°C at 660°C Type T: ±0.8°C at 400°C Type E: ±0.7°C at 660°C Type R: ±1.4°C at 660°C Type S: ±1.5°C at 660°C Type M: ±1.4°C at 660°C Type L: ±0.7°C at 660°C Type U: ±0.75°C at 600°C Type N: ±0.9°C at 660°C Type C: ±1.1°C at 660°C
Built-in RTD thermometer readout accuracy
NI-120: ±0.015°C at 0°C PT-100 (385): ±0.02°C at 0°C PT-100 (3926): ±0.02°C at 0°C PT-100 (JIS): ±0.02°C at 0°C
Built-in reference thermometer readout accuracy (4-wire reference probe)1
±0.010°C at -25°C ±0.015°C at 0°C ±0.020°C at 50°C ±0.025°C at 150°C ±0.030°C at 200°C ±0.040°C at 350°C ±0.050°C at 420°C ±0.070°C at 660°C
Built-in mA readout accuracy
0.02% of reading + 2 mV
Reference resistance accuracy2
0 ohms to 42 ohms: ±0.0025 ohms 42 ohms to 400 ohms: ±60 ppm of reading
RTD characterizations
PT-100 (385),(JIS),(3926), NI-120, Resistance
Reference measurement capability
4-wire
RTD resistance range
0 ohms to 400 ohms
Voltage accuracy
0.025% of reading + 0.01 mV
TC millivolt range
–10 mV to 75 mV
Built-in electronics temperature Coefficient (0°C to 13°C, 33°C to 50°C)
±0.005% of range per°C
RTD connection
4 terminal input
RTD measurement capability
4-wire RTD (2-,3-wire RTD w/ Jumpers only)
Reference probe connection
6-pin Din with Infocon Technology
RTD resistance accuracy2
25 ohms to 400 ohms: ±80 ppm of reading 0 ohms to 25 ohms: ±0.002 ohms
Reference characterizations
ITS-90, CVD, IEC-751, Resistance
TC connection
Small connectors

Base Unit Specifications

Loading effect (with a 6.35 mm reference probe and three 6.35 mm probes)
±0.015°C at 50°C ±0.025°C at 420°C ±0.035°C at 660°C
Computer interface
RS-232 and 9930 Interface-it control software included
Immersion (well) depth
150 mm (5.9 in)
Heating time
15 min: 50°C to 660°C
Display accuracy
±0.35°C at 50°C ±0.35°C at 420°C ±0.5°C at 660°C
Axial uniformity at 40 mm (1.6 in)
±0.05°C at 50°C ±0.35°C at 420°C±0.5°C at 660°C
Stability
±0.03°C at 50°C ±0.04°C at 420°C±0.05°C at 660°C
Temperature range at 23°C
50°C to 660°C (122°F to 1220°F)
Radial uniformity
±0.02°C at 50°C ±0.05°C at 420°C±0.10°C at 660°C
Insert OD
24.4 mm (0.96 in)
Resolution
0.01°
Display
LCD, °C or °F user-selectable
Size (H x W x D)
290 x 185 x 295 mm (11.4 x 7.3 x 11.6 in)
Weight
7.7 kg (17 lb)
Operating conditions
0°C to 50°C, 0% to 90% RH (non-condensing)
Cooling time
25 min: 660°C to 100°C 35 min: 660°C to 50°C
Hysteresis
0.1
Environmental conditions (for all specifications except temperature range)
13°C to 33°C
Power requirements
100 V to 115 V (±10%), 50/60 Hz, 1400 W 230 V (±10%), 50/60 Hz, 1800 W