The Fluke 9190A Ultra-Cool Field Metrology Well is the most accurate and stable, cold temperature dry-block on the market.
9190A-A-P
9190A-A-P
9190A-A-P
9190A-A-P
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

P Specifications

Built-in RTD thermometer readout accuracy
PT-100 (3926): ±0.02°C at 0°C
TC connection
Miniature connectors (ASTM E1684)
Reference probe connection
6-pin din with INFO-CON technology
Reference characterizations
ITS-90, CVD, IEC-751, resistance
MA range
Cal 4-22 mA, Spec 4-24 mA
Built-in electronics temperature coefficient (0°C to 13°C, 33°C to 50°C)
±0.005% of range per °C
Built-in RTD thermometer readout accuracy
NI-120: ±0.015°C at 0°C
Built-in TC thermometer readout accuracy5
Type T: ±0.60°C at 140°C
RTD characterizations
PT-100 (385), (JIS), (3926), NI-120, resistance
MA connection
2 terminal input
Built-in RTD thermometer readout accuracy
PT-100 (JIS): ±0.02°C at 0°C
Internal cold junction compensation accuracy
±0.35°C (ambient of 13°C to 33°C)
Built-in TC thermometer readout accuracy5
Type R: ±1.60°C at 140°C
Loop power function
24 V DC loop power
RTD connection
4-terminal input
Voltage accuracy
0.025% of reading +0.01 mV
Built-in reference thermometer readout accuracy (4-wire reference probe)3
±0.010°C at –95°C
Built-in TC thermometer readout accuracy5
Type J: ±0.70°C at 140°C
Reference resistance range
0 Ω to 400 Ω
Built-in TC thermometer readout accuracy5
Type E: ±0.60°C at 140°C
Built-in TC thermometer readout accuracy5
Type N: ±0.75°C at 140°C
Built-in reference thermometer readout accuracy (4-wire reference probe)3
±0.015°C at 0°C
Built-in reference thermometer readout accuracy (4-wire reference probe)3
±0.025°C at 140°C
Resistance accuracy4
0 Ω to 25 Ω: ±0.002 Ω
Resistance accuracy4
25 Ω to 400 Ω: ±80 ppm of reading
Built-in TC thermometer readout accuracy5
Type S: ±1.60°C at 140°C
RTD resistance range
0 Ω to 400 Ω
Reference measurement capability
4 wire
Built-in mA readout accuracy
0.02% of reading + 0.002 mA
RTD measurement capability
2-wire, 3-wire, and 4-wire RTD with jumpers only
Built-in TC thermometer readout accuracy5
Type C: ±1.00°C at 140°C
Built-in reference thermometer readout accuracy (4-wire reference probe)3
±0.013°C at –25°C
Built-in TC thermometer readout accuracy5
Type L: ±0.65°C at 140°C
Built-in RTD thermometer readout accuracy
PT-100 (385): ±0.02°C at 0°C
Built-in reference thermometer readout accuracy (4-wire reference probe)3
±0.020°C at 50°C
Built-in TC thermometer readout accuracy5
Type K: ±0.75°C at 140°C
Built-in TC thermometer readout accuracy5
Type M: ±0.65°C at 140°C
TC millivolt range
–10 mV to 75 mV
Built-in TC thermometer readout accuracy5
Type U: ±0.70°C at 140°C
Reference resistance accuracy4
0 Ω to 42 Ω: ±0.0025 Ω 42 Ω to 400 Ω: ±60 ppm of reading
Built-in electronics temperature coefficient (0°C to 13°C, 33°C to 50°C)
1. For ambient temperature of 23°C. 2. Time from when the SETPOINT is reached to when the unit is with in stability specification. 3. The temperature range may be limited by the reference probe connected to the readout. The built-in reference accuracy does not include the sensor probe accuracy. It does not include the probe uncertainty or probe characterization errors. 4. Measurement accuracy specifications apply within the operating range and assume 4 wires for PRTs. With 3-wire RTDs add 0.05 Ω to the measurement accuracy plus the maximum possible difference between the resistances of the lead wires. 5. The thermocouple input readout is sensitive to EM fields in the frequency range of 500 MHz to 700 MHz.

Specifications

Power requirements
200 V to 230 V (±10%) 50/60 Hz, 575 W
Stabilization time2
15 min
Cooling time1
140°C to 23°C: 60 min
Loading effect
±0.10°C at 140°C
Loading effect
±0.006°C full range
Weight
16 kg (35 lb)
Heating time1
–95°C to 140°C: 40 min
Refrigerants
< 20 g, ASHRAE safety group A2L
Display
LCD, °C or °F user selectable
Axial uniformity at 40 mm (1.6 in)
±0.05°C full range
Loading effect
±0.25°C at –95°C
Computer interface
RS-232, USB Serial, and 9930 interface-it temperature calibration software included
Environmental conditions for all specifications except temperature range
13°C to 33°C
Size (H x W x D)
480 x 205 x 380 mm (18.8 x 8.0 x 14.9 in)
Stability
±0.015°C full range
Radial gradient
±0.01°C full range
Loading effect
(versus display with one 6.35 mm probe)
Refrigerants
< 20 g, ASHRAE safety group A1
4–20 mA fuse (-P model only)
50 mA F 250 V
System fuse ratings
230 V: 3.15 A T 250 V
Electromagnetic environment
IEC 61326-1: Basic
Operating conditions
RH (non-condensing) < 2000 m altitude
Power requirements
100 V to 115 V (±10%) 50/60 Hz, 575 W
Immersion (well) depth
160 mm (6.3 in)
Well diameter
30 mm (1.18 in)
Refrigerants
R32 (Difluoromethane)
Display accuracy
±0.2°C full range
Accuracy with external reference3
±0.05°C full range
Refrigerants
R704 (Helium)
Operating conditions
0°C to 35°C, 0% to 90%
Temperature range at 23°C
–95°C to 140°C (–139°F to 284°F)
Loading effect
(with a 6.35 mm reference probe and three 6.35 mm probes)
Resolution
0.01°
System fuse ratings
115 V: 6.3 A T 250 V
Cooling time1
23°C to –90°C: 80 min
Cooling time1
23°C to –95°C: 90 min
Safety
IEC 61010-1, Installation Category II, Pollution degree 2