Fluke

9190A-B-P

The Fluke 9190A Ultra-Cool Field Metrology Well is the most accurate and stable, cold temperature dry-block on the market.
9190A-B-P
9190A-B-P
9190A-B-P
9190A-B-P
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

P Specifications

Built-in reference thermometer readout accuracy (4-wire reference probe)3
±0.013°C at –25°C
TC millivolt range
–10 mV to 75 mV
RTD resistance range
0 Ω to 400 Ω
Built-in mA readout accuracy
0.02% of reading + 0.002 mA
MA range
Cal 4-22 mA, Spec 4-24 mA
Built-in RTD thermometer readout accuracy
PT-100 (385): ±0.02°C at 0°C
Built-in electronics temperature coefficient (0°C to 13°C, 33°C to 50°C)
±0.005% of range per °C
Reference characterizations
ITS-90, CVD, IEC-751, resistance
Built-in TC thermometer readout accuracy5
Type E: ±0.60°C at 140°C
Built-in reference thermometer readout accuracy (4-wire reference probe)3
±0.025°C at 140°C
Built-in reference thermometer readout accuracy (4-wire reference probe)3
±0.010°C at –95°C
Built-in TC thermometer readout accuracy5
Type U: ±0.70°C at 140°C
Reference resistance range
0 Ω to 400 Ω
Internal cold junction compensation accuracy
±0.35°C (ambient of 13°C to 33°C)
TC connection
Miniature connectors (ASTM E1684)
Built-in TC thermometer readout accuracy5
Type M: ±0.65°C at 140°C
Built-in TC thermometer readout accuracy5
Type K: ±0.75°C at 140°C
Built-in TC thermometer readout accuracy5
Type L: ±0.65°C at 140°C
Built-in TC thermometer readout accuracy5
Type N: ±0.75°C at 140°C
Built-in RTD thermometer readout accuracy
NI-120: ±0.015°C at 0°C
Built-in reference thermometer readout accuracy (4-wire reference probe)3
±0.015°C at 0°C
Built-in TC thermometer readout accuracy5
Type R: ±1.60°C at 140°C
Voltage accuracy
0.025% of reading +0.01 mV
Resistance accuracy4
25 Ω to 400 Ω: ±80 ppm of reading
Built-in TC thermometer readout accuracy5
Type J: ±0.70°C at 140°C
Loop power function
24 V DC loop power
RTD connection
4-terminal input
Built-in TC thermometer readout accuracy5
Type S: ±1.60°C at 140°C
MA connection
2 terminal input
Reference resistance accuracy4
0 Ω to 42 Ω: ±0.0025 Ω 42 Ω to 400 Ω: ±60 ppm of reading
Built-in reference thermometer readout accuracy (4-wire reference probe)3
±0.020°C at 50°C
Built-in TC thermometer readout accuracy5
Type C: ±1.00°C at 140°C
RTD measurement capability
2-wire, 3-wire, and 4-wire RTD with jumpers only
Built-in TC thermometer readout accuracy5
Type T: ±0.60°C at 140°C
Reference probe connection
6-pin din with INFO-CON technology
Built-in RTD thermometer readout accuracy
PT-100 (JIS): ±0.02°C at 0°C
Built-in RTD thermometer readout accuracy
PT-100 (3926): ±0.02°C at 0°C
Reference measurement capability
4 wire
Built-in electronics temperature coefficient (0°C to 13°C, 33°C to 50°C)
1. For ambient temperature of 23°C. 2. Time from when the SETPOINT is reached to when the unit is with in stability specification. 3. The temperature range may be limited by the reference probe connected to the readout. The built-in reference accuracy does not include the sensor probe accuracy. It does not include the probe uncertainty or probe characterization errors. 4. Measurement accuracy specifications apply within the operating range and assume 4 wires for PRTs. With 3-wire RTDs add 0.05 Ω to the measurement accuracy plus the maximum possible difference between the resistances of the lead wires. 5. The thermocouple input readout is sensitive to EM fields in the frequency range of 500 MHz to 700 MHz.
RTD characterizations
PT-100 (385), (JIS), (3926), NI-120, resistance
Resistance accuracy4
0 Ω to 25 Ω: ±0.002 Ω

Specifications

Power requirements
200 V to 230 V (±10%) 50/60 Hz, 575 W
Size (H x W x D)
480 x 205 x 380 mm (18.8 x 8.0 x 14.9 in)
Refrigerants
< 20 g, ASHRAE safety group A2L
Axial uniformity at 40 mm (1.6 in)
±0.05°C full range
Weight
16 kg (35 lb)
Stability
±0.015°C full range
Immersion (well) depth
160 mm (6.3 in)
Operating conditions
RH (non-condensing) < 2000 m altitude
Display
LCD, °C or °F user selectable
Electromagnetic environment
IEC 61326-1: Basic
Computer interface
RS-232, USB Serial, and 9930 interface-it temperature calibration software included
System fuse ratings
115 V: 6.3 A T 250 V
Radial gradient
±0.01°C full range
4–20 mA fuse (-P model only)
50 mA F 250 V
Refrigerants
R32 (Difluoromethane)
Loading effect
±0.25°C at –95°C
Loading effect
±0.006°C full range
Power requirements
100 V to 115 V (±10%) 50/60 Hz, 575 W
Well diameter
30 mm (1.18 in)
Refrigerants
R704 (Helium)
Stabilization time2
15 min
Loading effect
±0.10°C at 140°C
Accuracy with external reference3
±0.05°C full range
Refrigerants
< 20 g, ASHRAE safety group A1
Loading effect
(versus display with one 6.35 mm probe)
Operating conditions
0°C to 35°C, 0% to 90%
Cooling time1
23°C to –95°C: 90 min
Temperature range at 23°C
–95°C to 140°C (–139°F to 284°F)
System fuse ratings
230 V: 3.15 A T 250 V
Loading effect
(with a 6.35 mm reference probe and three 6.35 mm probes)
Heating time1
–95°C to 140°C: 40 min
Cooling time1
23°C to –90°C: 80 min
Display accuracy
±0.2°C full range
Environmental conditions for all specifications except temperature range
13°C to 33°C
Safety
IEC 61010-1, Installation Category II, Pollution degree 2
Resolution
0.01°
Cooling time1
140°C to 23°C: 60 min