9190A-D-P

The Fluke 9190A Ultra-Cool Field Metrology Well is the most accurate and stable, cold temperature dry-block on the market.
9190A-D-P
9190A-D-P
9190A-D-P
9190A-D-P
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

P Specifications

Built-in electronics temperature coefficient (0°C to 13°C, 33°C to 50°C)
±0.005% of range per °C
Built-in TC thermometer readout accuracy5
Type L: ±0.65°C at 140°C
Loop power function
24 V DC loop power
Built-in TC thermometer readout accuracy5
Type U: ±0.70°C at 140°C
Built-in reference thermometer readout accuracy (4-wire reference probe)3
±0.015°C at 0°C
Resistance accuracy4
25 Ω to 400 Ω: ±80 ppm of reading
Built-in TC thermometer readout accuracy5
Type K: ±0.75°C at 140°C
TC millivolt range
–10 mV to 75 mV
RTD connection
4-terminal input
Built-in TC thermometer readout accuracy5
Type M: ±0.65°C at 140°C
Built-in TC thermometer readout accuracy5
Type S: ±1.60°C at 140°C
Reference probe connection
6-pin din with INFO-CON technology
Built-in TC thermometer readout accuracy5
Type C: ±1.00°C at 140°C
Built-in RTD thermometer readout accuracy
PT-100 (3926): ±0.02°C at 0°C
Built-in RTD thermometer readout accuracy
NI-120: ±0.015°C at 0°C
Built-in electronics temperature coefficient (0°C to 13°C, 33°C to 50°C)
1. For ambient temperature of 23°C. 2. Time from when the SETPOINT is reached to when the unit is with in stability specification. 3. The temperature range may be limited by the reference probe connected to the readout. The built-in reference accuracy does not include the sensor probe accuracy. It does not include the probe uncertainty or probe characterization errors. 4. Measurement accuracy specifications apply within the operating range and assume 4 wires for PRTs. With 3-wire RTDs add 0.05 Ω to the measurement accuracy plus the maximum possible difference between the resistances of the lead wires. 5. The thermocouple input readout is sensitive to EM fields in the frequency range of 500 MHz to 700 MHz.
RTD resistance range
0 Ω to 400 Ω
Built-in mA readout accuracy
0.02% of reading + 0.002 mA
Built-in TC thermometer readout accuracy5
Type J: ±0.70°C at 140°C
Built-in RTD thermometer readout accuracy
PT-100 (385): ±0.02°C at 0°C
MA connection
2 terminal input
RTD characterizations
PT-100 (385), (JIS), (3926), NI-120, resistance
Reference measurement capability
4 wire
Reference characterizations
ITS-90, CVD, IEC-751, resistance
Reference resistance range
0 Ω to 400 Ω
Built-in TC thermometer readout accuracy5
Type E: ±0.60°C at 140°C
Built-in reference thermometer readout accuracy (4-wire reference probe)3
±0.010°C at –95°C
RTD measurement capability
2-wire, 3-wire, and 4-wire RTD with jumpers only
Built-in reference thermometer readout accuracy (4-wire reference probe)3
±0.020°C at 50°C
Built-in reference thermometer readout accuracy (4-wire reference probe)3
±0.013°C at –25°C
Reference resistance accuracy4
0 Ω to 42 Ω: ±0.0025 Ω 42 Ω to 400 Ω: ±60 ppm of reading
Resistance accuracy4
0 Ω to 25 Ω: ±0.002 Ω
Built-in RTD thermometer readout accuracy
PT-100 (JIS): ±0.02°C at 0°C
Built-in TC thermometer readout accuracy5
Type T: ±0.60°C at 140°C
Built-in TC thermometer readout accuracy5
Type R: ±1.60°C at 140°C
Voltage accuracy
0.025% of reading +0.01 mV
Built-in reference thermometer readout accuracy (4-wire reference probe)3
±0.025°C at 140°C
TC connection
Miniature connectors (ASTM E1684)
Internal cold junction compensation accuracy
±0.35°C (ambient of 13°C to 33°C)
Built-in TC thermometer readout accuracy5
Type N: ±0.75°C at 140°C
MA range
Cal 4-22 mA, Spec 4-24 mA

Specifications

Refrigerants
R32 (Difluoromethane)
Radial gradient
±0.01°C full range
Electromagnetic environment
IEC 61326-1: Basic
Stabilization time2
15 min
Resolution
0.01°
Axial uniformity at 40 mm (1.6 in)
±0.05°C full range
Loading effect
±0.006°C full range
Cooling time1
23°C to –90°C: 80 min
Refrigerants
R704 (Helium)
Environmental conditions for all specifications except temperature range
13°C to 33°C
Size (H x W x D)
480 x 205 x 380 mm (18.8 x 8.0 x 14.9 in)
Power requirements
200 V to 230 V (±10%) 50/60 Hz, 575 W
Well diameter
30 mm (1.18 in)
System fuse ratings
115 V: 6.3 A T 250 V
Loading effect
(with a 6.35 mm reference probe and three 6.35 mm probes)
Loading effect
±0.10°C at 140°C
Weight
16 kg (35 lb)
Temperature range at 23°C
–95°C to 140°C (–139°F to 284°F)
Computer interface
RS-232, USB Serial, and 9930 interface-it temperature calibration software included
Display accuracy
±0.2°C full range
Loading effect
±0.25°C at –95°C
Refrigerants
< 20 g, ASHRAE safety group A1
Cooling time1
23°C to –95°C: 90 min
Loading effect
(versus display with one 6.35 mm probe)
Operating conditions
RH (non-condensing) < 2000 m altitude
Power requirements
100 V to 115 V (±10%) 50/60 Hz, 575 W
System fuse ratings
230 V: 3.15 A T 250 V
Stability
±0.015°C full range
Refrigerants
< 20 g, ASHRAE safety group A2L
Safety
IEC 61010-1, Installation Category II, Pollution degree 2
Operating conditions
0°C to 35°C, 0% to 90%
Heating time1
–95°C to 140°C: 40 min
Cooling time1
140°C to 23°C: 60 min
Immersion (well) depth
160 mm (6.3 in)
4–20 mA fuse (-P model only)
50 mA F 250 V
Display
LCD, °C or °F user selectable
Accuracy with external reference3
±0.05°C full range