Fluke

9190A-F-P

The Fluke 9190A Ultra-Cool Field Metrology Well is the most accurate and stable, cold temperature dry-block on the market.
9190A-F-P
9190A-F-P
9190A-F-P
9190A-F-P
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Specifications

Refrigerants
< 20 g, ASHRAE safety group A1
Safety
IEC 61010-1, Installation Category II, Pollution degree 2
Electromagnetic environment
IEC 61326-1: Basic
Computer interface
RS-232, USB Serial, and 9930 interface-it temperature calibration software included
Stabilization time2
15 min
Display
LCD, °C or °F user selectable
Display accuracy
±0.2°C full range
Refrigerants
R704 (Helium)
Operating conditions
RH (non-condensing) < 2000 m altitude
Immersion (well) depth
160 mm (6.3 in)
System fuse ratings
230 V: 3.15 A T 250 V
Loading effect
±0.25°C at –95°C
Environmental conditions for all specifications except temperature range
13°C to 33°C
Refrigerants
R32 (Difluoromethane)
Well diameter
30 mm (1.18 in)
Axial uniformity at 40 mm (1.6 in)
±0.05°C full range
Radial gradient
±0.01°C full range
Cooling time1
23°C to –90°C: 80 min
Heating time1
–95°C to 140°C: 40 min
Operating conditions
0°C to 35°C, 0% to 90%
Cooling time1
23°C to –95°C: 90 min
Power requirements
200 V to 230 V (±10%) 50/60 Hz, 575 W
4–20 mA fuse (-P model only)
50 mA F 250 V
Refrigerants
< 20 g, ASHRAE safety group A2L
Weight
16 kg (35 lb)
Size (H x W x D)
480 x 205 x 380 mm (18.8 x 8.0 x 14.9 in)
Cooling time1
140°C to 23°C: 60 min
Loading effect
±0.10°C at 140°C
Loading effect
(with a 6.35 mm reference probe and three 6.35 mm probes)
Resolution
0.01°
Power requirements
100 V to 115 V (±10%) 50/60 Hz, 575 W
Stability
±0.015°C full range
System fuse ratings
115 V: 6.3 A T 250 V
Accuracy with external reference3
±0.05°C full range
Loading effect
(versus display with one 6.35 mm probe)
Temperature range at 23°C
–95°C to 140°C (–139°F to 284°F)
Loading effect
±0.006°C full range

P Specifications

Built-in TC thermometer readout accuracy5
Type S: ±1.60°C at 140°C
Built-in RTD thermometer readout accuracy
PT-100 (JIS): ±0.02°C at 0°C
Built-in TC thermometer readout accuracy5
Type K: ±0.75°C at 140°C
Built-in TC thermometer readout accuracy5
Type L: ±0.65°C at 140°C
TC millivolt range
–10 mV to 75 mV
Reference resistance accuracy4
0 Ω to 42 Ω: ±0.0025 Ω 42 Ω to 400 Ω: ±60 ppm of reading
Built-in TC thermometer readout accuracy5
Type J: ±0.70°C at 140°C
Reference measurement capability
4 wire
RTD connection
4-terminal input
Built-in reference thermometer readout accuracy (4-wire reference probe)3
±0.010°C at –95°C
MA connection
2 terminal input
Built-in TC thermometer readout accuracy5
Type U: ±0.70°C at 140°C
Built-in TC thermometer readout accuracy5
Type T: ±0.60°C at 140°C
Built-in reference thermometer readout accuracy (4-wire reference probe)3
±0.013°C at –25°C
Loop power function
24 V DC loop power
Built-in TC thermometer readout accuracy5
Type C: ±1.00°C at 140°C
RTD measurement capability
2-wire, 3-wire, and 4-wire RTD with jumpers only
Resistance accuracy4
0 Ω to 25 Ω: ±0.002 Ω
Voltage accuracy
0.025% of reading +0.01 mV
Built-in reference thermometer readout accuracy (4-wire reference probe)3
±0.015°C at 0°C
Built-in RTD thermometer readout accuracy
PT-100 (3926): ±0.02°C at 0°C
Built-in mA readout accuracy
0.02% of reading + 0.002 mA
Built-in TC thermometer readout accuracy5
Type R: ±1.60°C at 140°C
Built-in reference thermometer readout accuracy (4-wire reference probe)3
±0.020°C at 50°C
TC connection
Miniature connectors (ASTM E1684)
RTD characterizations
PT-100 (385), (JIS), (3926), NI-120, resistance
Reference resistance range
0 Ω to 400 Ω
Reference characterizations
ITS-90, CVD, IEC-751, resistance
Built-in electronics temperature coefficient (0°C to 13°C, 33°C to 50°C)
±0.005% of range per °C
Internal cold junction compensation accuracy
±0.35°C (ambient of 13°C to 33°C)
Built-in reference thermometer readout accuracy (4-wire reference probe)3
±0.025°C at 140°C
MA range
Cal 4-22 mA, Spec 4-24 mA
Resistance accuracy4
25 Ω to 400 Ω: ±80 ppm of reading
Built-in RTD thermometer readout accuracy
PT-100 (385): ±0.02°C at 0°C
Built-in TC thermometer readout accuracy5
Type E: ±0.60°C at 140°C
RTD resistance range
0 Ω to 400 Ω
Built-in electronics temperature coefficient (0°C to 13°C, 33°C to 50°C)
1. For ambient temperature of 23°C. 2. Time from when the SETPOINT is reached to when the unit is with in stability specification. 3. The temperature range may be limited by the reference probe connected to the readout. The built-in reference accuracy does not include the sensor probe accuracy. It does not include the probe uncertainty or probe characterization errors. 4. Measurement accuracy specifications apply within the operating range and assume 4 wires for PRTs. With 3-wire RTDs add 0.05 Ω to the measurement accuracy plus the maximum possible difference between the resistances of the lead wires. 5. The thermocouple input readout is sensitive to EM fields in the frequency range of 500 MHz to 700 MHz.
Built-in RTD thermometer readout accuracy
NI-120: ±0.015°C at 0°C
Built-in TC thermometer readout accuracy5
Type M: ±0.65°C at 140°C
Built-in TC thermometer readout accuracy5
Type N: ±0.75°C at 140°C
Reference probe connection
6-pin din with INFO-CON technology