Fluke

FLK-3000 FC

FLK-3000 FC
FLK-3000 FC
FLK-3000 FC
FLK-3000 FC
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
€431.76
1
Payment methods:
A total of 88 Parts In-Stock from 2 Distributors

mA Function

Overload protection
Fused, 44/100 A, 1000 V FAST Fuse
Overload
600 mA overload for 2 minutes maximum, 10 minutes rest minimum

AC Voltage

Range¹ / resolution
600.0 mV / 0.1 mV6.000 V / 0.001 V60.00 V / 0.01 V600.0 V / 0.1 V1000 V / 1 V
Accuracy234
45 Hz to 500 Hz: 1.0% + 3
Accuracy
500 Hz to 1 kHz: 2.0% + 3
MV Range / resolution
600.0 mV / 0.1 mV
MV Accuracy
0.09% + 2
V Range / resolution
6.000 V / 0.001 V60.00 V / 0.01 V600.0 V / 0.1 V1000 V / 1 V
V Accuracy
0.09% + 20.15% + 2
))) Range / resolution
600 Ω / 1 Ω
))) Accuracy
Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer.
Ω Range / resolution
600.0 Ω / 0.1 Ω6.000 kΩ / 0.001 kΩ60.00 kΩ / 0.01 kΩ60.00 kΩ / 0.1 kΩ600.0 kΩ / 0.001 MΩ50.00 MΩ / 0.01 MΩ
Ω Accuracy
0.5% + 20.5% + 11.5% + 3
Diode test Range / resolution
2.000 V / 0.001 V
Diode test Accuracy
1% + 2
ΜF Range / resolution
1000 nF / 1 nF10.00 μF / 0.01 μF100.0 μF / 0.1 μF9999 μF1 / 1 μF
ΜF Accuracy
1.2% + 210% typical

MIN/MAX Recording Accuracy

DC functions
± 12 counts for changes > 350 mS in duration.
AC functions
± 40 counts for changes > 900 mS in duration.

AC and DC Current

MA AC(45 Hz to 1 kHz) Range1 / resolution
60.00 mA / 0.01 mA400.0 mA3 / 0.1 mA
MA AC Accuracy
1.5% + 3
MA DC2 Range1 / resolution
60.00 mA / 0.01 mA400.0 mA3 / 0.1 mA
MA DC Accuracy
0.5% + 3

General Specifications

Maximum voltage between any terminal and earth ground
1000 V DC or AC RMS
Ω fuse protection from A inputs
0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
Display (LCD) Update rate
4/sec
Display (LCD)
Volts, amps, ohms: 6000 counts
Display (LCD) Frequency
10,000 counts
Capacitance
1,000 counts
Battery type
Three AA Alkaline batteries, NEDA 15A IEC LR6
Battery life
250 hours minimum
RF communications
2.4 GHZ ISM Band
RF communication range Open air, unobstructed
Up to 20m
RF communication range Obstructed, sheetrock wall
Up to 6.5m
Obstructed, concrete wall, or steel electrical enclosure
Up to 3.5m
Temperature
Operating: -10°C to 50°C
Temperature Storage
-40°C to 60°C
Temperature coefficient
0.1 X (specified accuracy) / °C (< 18°C or > 28°C)
Relative humidity
0% to 90% (0°C to 35°C)0% to 75% (35°C to 40°C)0% to 45% (40°C to 50°C)
Altitude
Operating: 2,000 m
Altitude Storage
12,000 m
Electromagnetic compatibilityEMI, RFI, EMC, RF
EN 61326–1:2006, EN 61326–2–2:2006ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489V1.8.1:2008FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249FCCID : FCC: T68–FDMMBLE IC: 6627A–FDMMBLE
Safety compliance
ANSI / ISA 61010–1 / (82.02.01): 3rd editionCAN / CSA-C22.2 No 61010-1-12: 3rd editionUL 61010–1: 3rd editionIEC / EN 61010–1:2010
Certifications
CSA, FCC, CE
Ingress Protection (IP) rating
IP54
Pollution Degree
2
Size (H x W x L)
4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in)
Weight
340 g (12 oz)
Warranty
Three years

Frequency

Range / resolution
99.99 Hz / 0.01 Hz999.9 Hz / 0.1 Hz9.999 kHz / 0.001 kHz99.99 kHz / 0.01 kHz
Accuracy1
0.1% + 1

Documents

Data Sheet

Download