1
Payment methods:
Function
- Resolution
- 0.1/1/10
- Resolution
- 0.1 V
- Accuracy
- 1% ±4 digits
- Range
- -10 to 400 °C (14 °F to 752 °F)
- Range
- Continuity beeper
- Range
- Contact temperature
- Crest Factor (50Hz or 60Hz)
- 2.5 MIN@220 A 3.0 MIN@180 A > 1.4 MIN@600 A Add 2% for CF>400 A
- Range
- Ohms
- Accuracy
- 1% ±8 digits
- Range
- 600.0 V
- Resolution
- 0.1/1 µF
- Accuracy
- 2.5% ±5 digit (65-400 Hz)
- Crest Factor (50Hz or 60Hz)
- V ac
- Beeper volume
- 75 dBA nom. 15 cm. from case front
- Resolution
- 0.01/0.1 A
- Resolution
- 0.1 V
- Range
- 100.0/1000 µF
- Range
- Capacitance
- Range
- µA
- Resolution
- 0.1 µA
- On threshold
- <=30 Ω
- Accuracy
- 2.0% ±5 digit (45-65 Hz)
- Accuracy
- 1.5% ±5 digits
- Accuracy
- 1% ±5 digits
- Range
- 200 µA
- Range
- V dc
- Resolution
- 0.1 C/F
- Range
- 600/6000/60.00 kΩ
- Range
- 60.00/600.0 A
- Accuracy
- 1% ±5 digits
- Range
- 600.0 V
- Accuracy
- 1.5% ±5 digits
Mechanical and General Specifications
- Maximum voltage between any terminal and earth ground
- 1000 V
- Radio Frequency Certification
- FCC ID:T68-FBLE IC:6627A-FBLE
- Operating humidity
- Non condensing (< 10 °C [50 °F]), ≤90 % RH (at 10 °C to 30 °C [50 °F to 86 °F]), ≤75 % RH (at 30 °C to 40 °C (86 °F to 104 °F)), ≤45 % RH (at 40 °C to 50 °C (104 °F to 122 °F))
- Dimensions
- 230 x 83.7 x 45.4mm (9.06 x 3.30 x 1.39 in)
- Safety
- IEC 61010-1, Pollution Degree 2 IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V IEC 61010-2-033: CAT III 1000 V / CAT IV 600 V
- Weight (meter only)
- 419 g (15 oz)
- Temperature
- Operating: -10 °C to +50 °C (14 °F to +122 °F) Storage: -40 °C to +60 °C (-40 °F to +140 °F)
- IP Rating
- IEC 60529: IP30, non-operating
- Electromagnetic Compatibility (EMC)
- International: IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A Korea (KCC): Class A Equipment (Industrial Broadcasting & Communication Equipment) USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
- Temperature coefficients
- Add 0.1 × specified accuracy for each degree C above 28 °C or below 18 °C
- Altitude
- Operating: 3,000 m (9,842 ft) Storage: 12,000 m (39,370 ft)
- Battery type
- 2 AA alkaline batteries, NEDA 15A, IEC LR6
Other Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther