Fluke

FLK-TiS75 9 Hz

With 320x240 resolution and manual focus, the TiS75 produces professional quality images to make it easy to both see and solve the problem.
FLK-TiS75 9 Hz
FLK-TiS75 9 Hz
FLK-TiS75 9 Hz
FLK-TiS75 9 Hz
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
€5,055.17
1
Payment methods:
A total of 7 Parts In-Stock from 2 Distributors

IR-Fusion Technology

Fast auto toggle between manual and auto modes
Yes
Minimum span (auto mode)
5 °C
Rugged, ergonomic design for one-handed use
Yes
Picture-In-Picture (PIP)
5 presets (0%, 25%, 50%, 75%, 100%)
Minimum span (manual mode)
2.5 °C
Ruggedized display
3.5 inch (landscape) 320x240 LCD
Laser pointer
Yes
AutoBlend™ mode
5 presets (0%, 25%, 50%, 75%, 100%)
Temperature measurement range (not calibrated below -10 °C)
-20 °C to +550 °C (-4 °F to 1022 °F)
Frame rate
9 Hz or 30 Hz
Level and span
Smooth auto and manual scaling
Focus system
Manual focus, Minimum focus distance, 0.15 m (6 in)
Built-in digital camera (visible light)
5 MP
Fast auto-rescale in manual mode
Yes
Thermal sensitivity (NETD)
≤ 0.08 °C at 30 °C target temp (80 mK)

Key Features

Wireless connectivity
Yes
Distance to spot
504:1
Field of view
35.7 ° x 26.8 °
Fluke Connect® app compatible
Yes (where available)
IFOV (spatial resolution)
2.0 mRad
Detector resolution
320x240

Battery

Battery life
Four+ hours
Batteries (field-replaceable, rechargeable)
Two lithium ion smart battery packs with five-segment LED display to show charge level
Battery charging system
Two-bay battery charger or in-imager charging
AC operation
AC operation with included power supply (100 V AC to 240 V AC, 50/60 Hz)
Battery charge time
2.5 hours to full charge

Data storage and Image Capture

IR-PhotoNotes™
Yes (3 images)
Radiometric video recording
Yes
Instant upload
Instantly upload captured images to Fluke Connect server with the use of a WiFi connection
Image file formats
Non-radiometric (.bmp) or (.jpeg) or fully-radiometric (.is2); No analysis software required for non-radiometric (.bmp, .jpg) files
Image capture, review, save mechanism
One-handed image capture, review, and save capability
Export file formats with SmartView® software
BMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF, and TIFF
Extensive SD memory system
Internal 4 GB memory and 4 GB removable micro SD card
Streaming video (remote display)
Yes
Standard video recording
Yes
Memory review
Thumbnail review
Software
SmartView® software - full analysis and reporting software and Fluke Connect® (where available)
Video file formats
Non-radiometric (MPEG - encoded .AVI) and fully radiometric (.IS3)
Voice annotation
Yes, Bluetooth Headset (sold separately)

Temperature Measurement

Standard palettes
8: Ironbow, Blue-Red, High-Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted
On-screen reflected background temperature compensation
Yes
Accuracy
±2 °C or 2% (at 25 °C nominal, whichever is greater)
On-screen transmission correction
Yes
Ultra Contrast™ palettes
8: Ironbow Ultra, Blue-Red Ultra, High-Contrast Ultra, Amber Ultra, Amber Inverted Ultra, Hot Metal Ultra, Grayscale Ultra, Grayscale Inverted Ultra
On-screen transmission correction
Color Palettes
On-screen emissivity correction
Yes (both value and table)

General Specifications

Infrared spectral band
7.5 μm to 14 μm
Relative humidity
10% to 95%, non-condensing
Spot temperature
Yes
Storage temperature
-20 °C to +50 °C (-4 °F to 122 °F)
US FCC
EN61326-1; FCC Part 5, EN 55011: Class A, EN 61000-4-2, EN 61000-4-3
Warranty
Two-years (standard), extended warranties are available
Center-point temperature measurement
Yes
Vibration and shock
2G, IEC 68-2-6 and 25G, IEC 68-2-29
User-definable spot markers
3
Center box
Expandable-contractible measurement box with MIN-MAX-AVG temp
Safety standards
EN 61010-1: CAT none, pollution degree 2, EN 60825-1: Class 2, EN 60529, EN 62133 (lithium battery)
Drop
Engineered to withstand 2 m (6.5 ft) drop
Weight (battery included)
Fixed focus .72 kg (1.6 lb), Manual focus .77 kg (1.7 lb)
Color alarms (temperature alarms)
High temperature, low temperature, Isotherms
C Tick
IEC/EN 61326-1
Recommended calibration cycle
Two-years (assumes normal operation and normal aging)
Size (H x W x L)
26.7 x 10.1 x 14.5 cm (10.5 x 4.0 x 5.7 in)
Operating temperature
-10 °C to +50 °C (14 °F to 122 °F)
Electromagnetic compatibility
EN 61326-1:2006, EN 55011: Class A, EN 61000-4-2, EN 61000-4-3
Supported languages
Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish
Enclosure rating
IP54 (protected against dust, limited ingress; protection against water spray from all directions)