FLK-TiX560-Tele2-60Hz-Kit

Reduce the need to enter the danger zone or climb a tall ladder to capture critical infrared details with the TiX560 infrared camera and a 2x telephoto lens.
FLK-TiX560-Tele2-60Hz-Kit
FLK-TiX560-Tele2-60Hz-Kit
FLK-TiX560-Tele2-60Hz-Kit
FLK-TiX560-Tele2-60Hz-Kit
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Key Features

Level and span
Smooth auto and manual scaling
LaserSharp® Auto Focus
Yes, for consistently in-focus images. Every. Single. Time.
Minimum span (in manual mode)
2.0 °C (3.6 °F)
IFOV with standard lens (spatial resolution)
1.31 mRad
Filter mode (NETD improvement)
≤ 0.03 °C at 30 °C target temp (30 mK)
Field of view
24 °H x 17 °V
Minimum focus distance
45 cm (approx. 18 in)
IR-Fusion® technology
Yes
Streaming video (remote display)
Via USB or WiFi
Digital zoom
2x, 4x, 8x
Wireless connectivity
Yes, to PC, iPhone® and iPad® (iOS 4s and later), Android™ 4.3 and up, and WiFi to LAN (where available)
Fluke Connect™ tool compatible
Yes (where available). Connects wirelessly to select Fluke Connect™ enabled tools. Five simultaneous connections supported.
Picture-In-Picture (PIP)
Yes
Touchscreen display (capacitive)
14.4 cm (5.7 in) diagonal landscape color VGA (640 x 480) LCD with backlight
Fast auto toggle between manual and auto modes
Yes
Advanced manual focus
Yes
Minimum span (in auto mode)
3.0 °C (5.4 °F)
Touchscreen adjustable level / span
Yes. Span and level can be easy and quickly set by simply touching the screen.
Laser distance meter
Yes, calculates distance to the target for precisely focused images and displays distance on screen
LED light (torch)
Yes
AutoBlend™ mode
Yes
IFOV with telephoto lens
0.65 mRad
Frame rate
60 Hz or 9 Hz versions
Built-in digital camera (visible light)
5 megapixel industrial performance
Fluke Connect™ app compatible
Yes (where available)
Fast auto-rescale in manual mode
Yes
Rugged, ergonomic design for one-handed use
Rotatable (articulating lens) >180 degrees
Image sharpening
Yes
Laser pointer
Yes
Minimum focus distance
15 cm (approx. 6 in)
Detector resolution
320 x 240 (76,800 pixels)
Thermal sensitivity (NETD)
≤ 0.045 °C at 30 °C target temp (45 mK)
Continuous AutoBlend™
Set AutoBlend™ level across continuum
Field of view
12 °H x 9 °V
SuperResolution
On camera and in software

Data Storage and Image Capture

Remote control and operation (for special and advanced applications)
Yes
Advanced text annotation
Yes. Including standard shortcuts as well as user programmable options.
File formats video
Non-radiometric (MPEG - encoded .AVI) and fully radiometric (.IS3)
Extensive memory options
Removable micro SD memory card, on-board flash memory, save-to-USB capability, direct download via USB-to-PC connection
IR-PhotoNotes™
Yes
Software
SmartView® software, Fluke Connect™ (where available), and SmartView® Mobile App - full analysis and reporting software
Text annotation
Yes
Memory review
Thumbnail view navigation and review selection
Video recording
Standard and radiometric
Auto capture (temperature and interval)
Yes
Export file formats with SmartView® software
BMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF, and TIFF
Post-capture image editing (on camera)
Yes. Conduct on camera analysis for in-field results.
Voice annotation
60 seconds maximum recording time per image; reviewable playback on camera; Bluetooth headset provided
File formats
Non-radiometric (.bmp) or (.jpeg) or fully radiometric (.is2); no analysis software required for non-radiometric (.bmp, .jpg and .avi) files

Battery

AC operation
AC operation with included power supply (100 V AC to 240 V AC, 50/60 Hz)
Power saving
User selectable sleep and power off modes
Battery charging system
Two-bay battery charger or in-imager charging. Optional 12 V automotive charging adapter
Battery charge time
2.5 hours to full charge
Batteries (field-replaceable, rechargeable)
Two lithium ion smart battery packs with five-segment LED display to show charge level
Battery life
Three hours continuous use per battery pack

Temperature Measurement

On-screen reflected background temperature compensation
Yes
Temperature measurement range (not calibrated below -10 °C)
'-20 °C to +1200 °C (-4 °F to +2192 °F)
Accuracy
± 2 °C or 2 % (at 25 °C nominal, whichever is greater)
On-screen emissivity correction
Yes (both value and table)
On-screen transmission correction
Yes

Color Palettes

Standard palettes
8: Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted
Ultra Contrast™ palettes
8: Ironbow Ultra, Blue-Red Ultra, High Contrast Ultra, Amber Ultra, Amber Inverted Ultra, Hot Metal Ultra, Grayscale Ultra, Grayscale Inverted Ultra

General Specifications

Center box
Expandable-contractible measurement box with MIN-MAX-AVG temp
Australian RCM
IEC/61326-1
Color alarms (temperature alarms)
High-temperature and low-temperature
Spot temperature
Hot and cold spot markers
Warranty
Two-years (standard), extended warranties are available
Storage temperature
-20 °C to +50 °C (-4 °F to 122 °F) without batteries
Weight (battery included)
1.5 kg (3.3 lb)
Electromagnetic compatibility
IEC 61326-1: Basic EM Environment CISPR11, Group 1, Class A
Safety
IEC 61010-1: Overvoltage Category II, Pollution degree 2
Recommended calibration cycle
Two-years (assumes normal operation and normal aging)
Supported languages
Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish
Infrared spectral band
7.5 μm to 14 μm (long wave)
Relative humidity
10 % to 95 % non-condensing
Enclosure rating
IP54 (protected against dust, limited ingress; protection against water spray from all directions)
Vibration
0.03 g2/Hz (3.8 grms), 2.5g IEC 68-2-6
Shock
25 g, IEC 68-2-29
Size (H x W x L)
27.3 cm x 15.9 cm x 9.7 cm (10.8 in x 6.3 in x 3.8 in)
US FCC
CFR 47, Part 15 Subpart B
Drop
Engineered to withstand 1 meter (3.4 feet) drop with standard lens
User-definable spot markers
3 user-definable spot markers
Operating temperature
-10 °C to +50 °C (14 °F to 122 °F)
Center-point temperature measurement
Yes