Fluke

FLK-VT04-M-Kit

FLK-VT04-M-Kit
FLK-VT04-M-Kit
FLK-VT04-M-Kit
FLK-VT04-M-Kit
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

General Features

Battery life
Eight (8) hours
Temperature measurement range
-10°C to +250°C (14°F to 482°F)
Temperature measurement accuracy
±2°C or ±2%
Temperature measurement
Yes, centerpoint
Storage medium (micro SD card)
Stores up to 10,000 images per Gb (4 Gb card included)
Infrared spectral band
6.5 μm to 14 μm
Level and span
Auto
Focus mechanism
Focus free, no training required with built-in intelligence
Focus options-exclusive user selectable NEAR/FAR options
NEAR < 23 cm (9 in); FAR > 23 cm (9 in)
Dimensions
21 x 7.5 x 5.5 cm (8.3 x 3 x 2.2 in); < 300 g (10.5 oz)
File format
is2 format saved to SD card. User can create professional reports or export images in SmartView (BMP, DIB, GIF, SPE, FIF, SPEG, JPG, PNG, TIF and TIFF)
Safety and compliance
CFR47: 2009 Class A. Part 15 subpart B; CE: EN 61326:2006; IEC/EN 61010-1:2010
Warranty
Two (2) years

Key Features

Built-in digital camera
Yes
Thermal heat map overlay
Yes, five blending modes
Image optics system
PyroBlend® Plus optic *4x sharper image than VT02
Field of view
28° x 28°
Hi-Lo temperature alarms
Yes
Time lapse image capture
Yes
Auto-monitor alarm
Yes
Battery type
Li-Ion rechargeable
Training
No training required
Ergonomics
Slim pocket-sized design
Hot and cold markers
Yes

Insulation Specifications

Measurement range
0.01 MΩ to 10 GΩ
Test voltage
50 V, 100 V, 250 V, 500 V, 1000 V
Test voltage accuracy
+20%, - 0%
Short circuit current
1 mA nominal
Auto discharge
Discharge time < 0.5 second for C = 1 µF or less
Live circuit indicator
Inhibit test if terminal voltage > 30 V prior to initialization of test
Maximum capacitive load
Operable with up to 1 µF load
Measure accuracy
50 V: ±(3% + 5) || 100 V: ±(3% + 5) || 250 V: ±(1.5% + 5) || 500 V: ±(1.5% + 5) || 1000 V: ±(1.5% + 5) to 2000 MΩ, ±(10% + 3) above 2000 MΩ

Earth Bond Resistance Measurement

Range/Resolution
20.00 Ω: 0.01 Ω || 200.0 Ω: 0.1 Ω || 2000 Ω: 1.0 Ω || 20.00 kΩ: 0.01 kΩ
Accuracy
±(1.5% + 3)
Overload protection
2 V rms or DC
Open circuit test voltage
> 4.0 V, < 8 V
Short circuit current
> 200.0 mA

AC/DC Voltage Measurement

Accuracy Range
600.0 V
Accuracy Resolution
0.1 V
Accuracy
50 Hz to 400 Hz±(% of Rdg + Digits): ±(2% + 3)
Input impedance
3 MΩ (nominal), < 100 pF
Common mode rejection ratio (1 kΩ unbalanced)
> 60 dB at DC, 50 or 60 Hz
Overload protection
600 V rms or DC

General Specifications

Maximum voltage applied to any terminal
600 V AC rms or DC
Storage temperature
-40°C to 60°C (-40°F to 140°F)
Operating temperature
-20°C to 55°C (-4°F to 131°F)
Temperature coefficient
0.05 x (specified accuracy) per°C for temperatures < 18°C or > 28°C (< 64°F or > 82°F)
Relative humidity
0% to 95% @ 10°C to 30°C (50°F to 86°F) || 0% to 75% @ 30°C to 40°C (86°F to 104°F) || 0% to 40% @ 40°C to 55°C (104°F to 131°F)
Vibration
Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument
Shock
1 meter drop per IEC 61010-1 2nd Edition (1 meter drop test, six sides, oak floor)
Electromagnetic compatibility
In an RF field of 3 V/M, accuracy = specified accuracy (EN 61326-1:1997)
Safety
Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement category IV 600 V (CAT IV)
Certifications
CSA per standard CSA/CAN C22.2 No. 61010.1-04; TUV per standard IEC/EN 61010-1 2nd Edition
Batteries
Four AA batteries (NEDA 15A or IEC LR6)
Battery life Insulation test use
Tester can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.
Battery life Resistance measurements
Tester can perform at least 2500 earth bond resistance measurements with fresh alkaline batteries at room temperature. These are standard tests of 1 Ω with a duty cycle of 5 seconds on and 25 seconds off.
Size (H x W x L)
5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in)
Weight
550 g (1.2 lb)
IP rating
IP40
Altitude
Operating: 2000 m CAT IV 600 V, 3000 m CAT III 600 V || Non-operating (storage): 12,000 m
Over-range capability
110% of range
Included accessories
TL224 Test Leads, TP74 Test Probes, clips PN 1958654 (red) and PN 1958646 (black), holster and remote probe