A total of 331 Parts In-Stock from 4 Distributors

Accuracy specifications

DC millivolts Range/resolution
600.0 mV / 0.1 mV
DC millivolts Accuracy
± ([% of reading] + [counts]): 0.5% + 2
DC volts Range/resolution
6.000 V / 0.001V60.00 V / 0.01V600.00 V / 0.1 V
DC volts Accuracy
± ([% of reading] + [counts]): 0.5% + 2
Auto volts Range/resolution
600.0 V / 0.1 V
Auto volts Accuracy
2.0% + 3 (DC, 45 Hz to 500 Hz)4.0% + 3 (500 Hz to 1 kHz)
AC millivolts1 True RMS Range/resolution
600.0 mV / 0.1 mV
AC millivolts Accuracy
1.0% + 3 (DC, 45 Hz to 500 Hz)2.0% + 3 (500 Hz to 1 kHz)
AC volts1 True RMS Range/resolution
6.000 V / 0.001V60.00 V / 0.01V600.0 V / 0.1 V
AC volts Accuracy
1.0% + 3 (DC, 45 Hz to 500 Hz)2.0% + 3 (500 Hz to 1 kHz)
Continuity Range/resolution
600 Ω / 1 Ω
Continuity Accuracy
Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of500 μs or longer.
Ohms Range/resolution
600.0 Ω / 0.1 Ω6.000 kΩ / 0.001 kΩ60.00 kΩ / 0.01 kΩ600.0 kΩ / 0.1 kΩ6.000 MΩ / 0.001 MΩ || 40.00 MΩ / 0.01 MΩ
Ohms Accuracy
0.9% + 1 || 5% + 2

Specifications

Maximum voltage between any terminal and earth ground
600 V
Surge protection
6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2
Display
Digital: 6,000 counts, updates 4 per second
Bar graph
33 segments, updates 32 per second
Operating temperature
-10°C to + 50°C
Storage temperature
-40°C to + 60°C
Battery type
9 volt Alkaline, NEDA 1604A / IEC 6LR61
Battery life
400 hours typical, without backlight

Mechanical & General Specifications

Size
167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)
Weight
550 g
Warranty
3 years

Documents

Data Sheet

Download