Fluke
FLUKE 116
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
1574,50 zł
1
Payment methods:
A total of 143 Parts In-Stock from 4 Distributors
Product Conditions:
Specifications
- Maximum voltage between any terminal and earth ground
- 600 V
- Surge protection
- 6 kV peak per IEC 61010–1 600 VCAT III, Pollution Degree 2
- Display
- Digital: 6,000 counts, updates 4 per second
- Bar graph
- 33 segments, updates 32 per second
- Operating temperature
- -10°C to + 50°C
- Storage temperature
- -40°C to + 60°C
- Battery type
- 9 volt Alkaline, NEDA 1604A/ IEC 6LR61
- Battery life
- 400 hours typical, without backlight
Accuracy Specifications
- DC millivolts Range/resolution
- 600.0 mV / 0.1 mV
- DC millivolts Accuracy
- ±([% of reading] + [counts]): 0.5% + 2
- DC volts Range/resolution
- 6.000 V / 0.001 V60.00 V / 0.01 V600.00 V / 0.1 V
- DC volts Accuracy
- ±([% of reading] + [counts]): 0.5% + 2
- Auto volts Range/resolution
- 600.0 V / 0.1 V
- Auto volts Accuracy
- 2.0% + 3 (DC, 45 Hz to 500 Hz)4.0% + 3 (500 Hz to 1 kHz)
- AC millivolts1 True RMS Range/resolution
- 600.0 mV / 0.1 mV
- AC millivolts Accuracy
- 1.0% + 3 (DC, 45 Hz to 500 Hz)2.0% + 3 (500 Hz to 1 kHz)
- AC volts1 True RMS Range/resolution
- 6.000 V / 0.001 V60.00 V / 0.01 V600.0 V / 0.1 V
- AC volts Accuracy
- 1.0% + 3 (DC, 45 Hz to 500 Hz)2.0% + 3 (500 Hz to 1 kHz)
- Continuity Range/resolution
- 600 Ω / 1 Ω
- Continuity Accuracy
- Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of500 μs or longer.
- Ohms Range/resolution
- 600.0 Ω / 0.1 Ω6.000 kΩ / 0.001 kΩ60.00 kΩ / 0.01 kΩ600.0 kΩ / 0.1 kΩ6.000 MΩ / 0.001 MΩ
- Ohms Accuracy
- 0.9% + 1 || 5% + 2
- Ohms Range/Resolution
- 40.00 MΩ / 0.01 MΩ
- Diode Test Range/resolution
- 2.00 V / 0.001 V
- Diode Test Accuracy
- 0.9% + 2
- Capacitance Range/resolution
- 1000 nF / 1 nF10.00 μF / 0.01 μF100.0 μF / 0.1 μF9999 μF / 1 μF100 μF to 1000 μF || > 1000 μF
- Capacitance Accuracy
- 1.9% + 2 || 5% + 20%
- Lo-Z Capacitance Range
- 1 nF to 500 μF
- Lo-Z Capacitance Accuracy
- 10% + 2 typical
- Temperature²(Type-K thermocouple) Range/resolution
- -40°C to 400°C / 0.1°C
- Temperature² Accuracy
- 1% + 10² || 1% + 18²
- Temperature² Range/resolution
- -40°F to 752°F / 0.2°F
- AC μA true-rms (45 Hz to 500 Hz) Range/resolution
- 600.0 μA / 0.1 μA
- AC μA true-rms (45 Hz to 500 Hz) Accuracy
- 1.5% + 3
- DC μamps Range/resolution
- 600.0 μA / 0.1 μA
- DC μamps Accuracy
- 1.0% + 2
- Hz (V or A input)² Range/resolution
- 99.99 Hz / 0.01 Hz999.9 Hz / 0.1 Hz9.999 kHz / 0.001 Hz50.00 kHz / 0.01 Hz
- Hz (V or A input)² Accuracy
- 0.1% + 2
Mechanical and General Specifications
- Size
- 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)
- Weight
- 550 g
- Warranty
- 3 years
Documents
Data Sheet
DownloadOther Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther