Mechanical and General Specifications
- Size
- 203 x 100 x 50 mm (with holster)
- Weight
- 624 g
- Warranty
- 3 years
- Battery life alkaline Meter use
- 1000 hours
- Battery life alkaline Insulation test use
- Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.
- IP rating
- IP40
Insulation Test
- Minimum test current @ 1kΩ/V
- 1 mA
- Test voltages
- 500, 1000 V
- Maximum resistance per test voltage
- 50 V || 100 V || 250 V || 500 V || 1000 V: 600 MΩ
- Maximum resolution per test voltage
- 50 V: 0.01 MΩ || 100 V: 0.01 MΩ || 250 V: 0.1 MΩ || 500 V: 0.1 MΩ || 1000 V: 0.1 MΩ
- Accuracy per test voltage
- 50 V: ±(3% + 5) || 100 V: ±(3% + 5) || 250 V: ±(1.5% + 5) || 500 V: ±(2.0% + 5) || 1000 V: ±(2.0% + 5)
Specifications
- Voltage DC Maximum voltage
- 1000 V
- Voltage DC Accuracy
- ±(0.2%+2)
- Voltage DC Maximum resolution
- 0.001 V
- Voltage AC Maximum voltage
- 1000 V
- Voltage AC Accuracy
- ±(2%+3)
- Voltage AC Maximum resolution
- 0.1 mV
- Current DC Maximum amps
- 400 mA
- Current DC Amps accuracy
- ±(1.0%+2)
- Current DC Maximum resolution
- 0.01 mA
- Current AC Maximum amps
- 400 mA
- Current AC Amps accuracy
- ±(2.0%+2)*
- Current AC Maximum resolution
- 0.01 mA
- Resistance Maximum resistance
- 50 MΩ
- Resistance Accuracy
- ±(1.2%+2)
- Resistance maximum resolution
- 0.1Ω
Safety Specifications
- Overvoltage category
- Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement CAT III 1000 V and CAT IV 600 V
- Agency approvals
- 2000 m CAT III 1000 V, CAT IV 600 V; 3000 m CAT II 1000 V, CAT III 600 V
Environmental Specifications
- Operating temperature
- –20°C to +55°C
- Storage temperature
- -40°C to +60°C
- Humidity (without condensation)
- 0% - 95% (10°C – 30°C)0% - 75% (30°C – 40°C)0% - 40% (40°C – 55°C)
- Operating altitude
- 2000 m
Documents
Data Sheet
DownloadOther Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther