Fluke

FLUKE 345

FLUKE 345
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Logging Memory

Logging areas
Three areas that can be used individually or combined into one large area
Averaging periods
1 s, 2 s, 5 s, 10 s, 30 s, 1 min, 5 min, 10 min, 15 min, and custom

Current measurement (DC, DC rms, AC rms)

Measuring range
0 to 2000 A DC or 1400 AC rms
Autorange facility
40 A / 400 A / 2000 A
Resolution
10 mA in 40 A range100 mA in 400 A rangeA in 2000 A range
Accuracy: DC and DC rms I > 10 A
±1.5% rdg ±5 digits
Accuracy: DC and DC rms I < 10 A
±0.2 A
Accuracy: AVG I > 10 A
±3% rdg ±5 digits
Accuracy: AVG I < 10 A
±0.5 A
Accuracy: Pk I > 10 A
±5% rdg ±5 digits
Accuracy: Pk I < 10 A
±0.5 A
Accuracy: AHr I > 10 A
±2% rdg ±5 digits
Accuracy: AHr I < 10 A
±0.5 AHr
Accuracy: CF (Crest Factor) 1.1 ≤ CF < 3
±3% rdg ±5 digits
Accuracy: CF (Crest Factor) 3 ≤ CF < 5
±5% rdg ±5 digits
Accuracy: CF (Crest Factor) Resolution
0.01
Accuracy: RPL (Ripple) 2% ≤ RPL < 100%
±3% rdg ±5 digits
Accuracy: RPL (Ripple) 100% ≤ RPL < 600%
±5% rdg ±5 digits
Accuracy: RPL (Ripple) Resolution
0.1%
Accuracy: RPL (Ripple)
I DC > 5 A, I AC > 2 A

Electrical data

Accuracy
23°C ±1°C (73.4°F ±1.8°F). See Ambient conditions specifications for temperature coefficients.

Interface

USB Interface to a PC
Power Log software for download, analysis and reporting345 Upgrade Utility for installing a new firmware version

Voltage measurement (DC, DC rms, AC rms)

Measuring range
0 to 825 VDC or AC rms
Autorange facility
4 V / 40 V / 400 V / 750 V
Resolution
1 mV in 4 V range10 mV in 40 V range100 mV in 400 V range1 V in 750 V range
Accuracy: DC and DC rms
V > 1 V: ±1% rdg ±5 digits || V < 1 V: ±0.02 V
Accuracy: AVG
V > 1 V: ±3% rdg ±5 digits || V < 1 V: ±0.03 V
Accuracy: Pk
V > 1 V: ±5% rdg ±5 digits || V < 1 V: ±0.03 V
Accuracy: CF (Crest Factor) 1.1 ≤ CF < 3
±3% rdg ±5 digits
Accuracy: CF (Crest Factor) 3 ≤ CF < 5
±5% rdg ±5 digits
Accuracy: CF (Crest Factor) Resolution
0.01
Accuracy: RPL (Ripple) 2% ≤ RPL < 100%
±3% rdg ±5 digits
Accuracy: RPL (Ripple) 100% ≤ RPL < 600%
±5% rdg ±5 digits
Accuracy: RPL (Ripple) Resolution
0.1%
Accuracy: RPL (Ripple)
VDC > 0.5 V, VAC > 0.2 V

Power factor (single- and three-phase)

Measuring range
0.3 capacitive to 1.0 and 1.0 to 0.3 inductive (72.5° capacitive to 0° and 0° to 72.5° inductive) || 0.3 capacitive to 1.0 and 1.0 to 0.3 inductive (72.5° capacitive to 0° and 0° to 72.5° inductive)
Resolution
0.001 || 0.001
Accuracy
±3° || ±3°
Frequency range
15 Hz to 1 kHz || 15 Hz to 22 Hz and 45 Hz to 65 Hz

Scope function

Current measurement Range
10 A / 20 A / 40 A / 100 A / 200 A / 400 A / 1000 A / 2000 A
Current measurement Resolution
1 A in 40 A10 A in 400 A50 A in 2000 A
Current measurement Accuracy
±3% rdg ±1 pixel
Current measurement Maximum overload
10,000 A
Voltage measurement Range
4 V / 10 V / 20 V / 40 V / 100 V / 200 V / 400 V / 1000 V
Voltage measurement Resolution
100 mV in 4 V1 V in 40 V10 V in 400 V31.25 V in 1000 V
Voltage measurement Accuracy
±2% rdg ±1 pixel
Voltage measurement Maximum overload
1000 V rms
Voltage measurement Frequency range
DC and 15 Hz to 600 Hz
Time base
2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms/div
Refresh rate
0.5 seconds
Maximum sampling rate
15.625 kHz

Logging Times

Volts and current mode Average time
Logging time (1 area)
Volts and current mode 1 s
1 h 49 m || 5 h 12 m
Volts and current mode 2 s
3 h 38 m || 10 h 24 m
Volts and current mode 5 s
9 h 6 m || 1 d 2 h 00 m
Volts and current mode 10 s
18 h 12 m || 2 d 4 h 00 m
Volts and current mode 30 s
2 d 6 h 36 m || 6 d 12 h 1 m
Volts and current mode
1 min: 4 d 13 h 12 m || 5 min: 22 d 18 h 0 m || 10 min: 45 d 12 h 0 m || 15 min: 68 d 6 h 0 m || 15 min: Logging time (3 areas) || 1 min: 13 d 0 h 12 m || 5 min: 65 d 0 h 15 m || 10 min: 130 d 0 h 30 m || 15 min: 195 d 0 h 45 m
V and A harmonics mode Average time
Logging time (1 area)
V and A harmonics mode 1 s
0 h 34 m || 1 h 38 m
V and A harmonics mode 2 s
1 h 8 m || 3 h 16 m
V and A harmonics mode 5 s
2 h 52 m || 8 h 11 m
V and A harmonics mode 10 s
5 h 44 m || 16 h 23 m
V and A harmonics mode 30 s
17 h 13 m || 2 d 1 h 11 m
V and A harmonics mode 1 m
1 d 10 h 26 m || 4 d 2 h 23 m
V and A harmonics mode 5 m
7 d 4 h 10 m || 20 d 11 h 25 m
V and A harmonics mode 10 m
14 d 8 h 20 m || 81 d 0 h 50 m
V and A harmonics mode 15 m
21 d 12 h 30 m || Logging time (3 areas) || 121 d 13 h 15 m
Single- and three-phase power mode Average time
Logging time (1 area)
Single- and three-phase power mode 1 s
1 h 40 m || 4 h 47 m
Single- and three-phase power mode 2 s
3 h 21 m || 9 h 34 m
Single- and three-phase power mode 5 s
8 h 22 m || 23 h 57 m
Single- and three-phase power mode 10 s
16 h 45 m || 1 d 23 h 54 m
Single- and three-phase power mode 30 s
2 d 2 h 17 m || 5 d 23 h 25 m
Single- and three-phase power mode 1 m
4 d 4 h 35 m || 11 d 23 h 25 m
Single- and three-phase power mode 5 m
20 d 22 h 55 m || 59 d 21 h 5 m
Single- and three-phase power mode 10 m
41 d 21 h 50 m || 119 d 18 h 10 m
Single- and three-phase power mode 15 m
62 d 20 h 45 m || Logging time (3 areas) || 179 d 15 h 15 m

Mechanical

Dimensions (L x W x D)
300 x 98 x 52 mm (12 x 3.75 x 2 in)
Weight including batteries
820 g (1.8 lb)
Jaw opening
60 mm
Jaw capacity
58 mm diameter
Cleaning
The unit can be cleaned with an Isopropanol impregnated cloth. Do not use abrasives or other solvents.

Kilowatt hour (kWHr)

Measuring range
40,000 kWHr || 15 Hz to 1 kHz
Autorange facility
4 kWHr, 40 kWHr, 400 kWHr, 4,000 kWHr, 40,000 kWHr
Resolution
1 WHr in 4 kWHr Range10 WHr in 40 kWHr Range100 WHr in 400 kWHr Range1 kWHr in 4,000 kWHr Range10 kWHr in 40,000 kWHr Range || 0.1 Hz
Accuracy kWHr > 2 kWHr
±3% ±5 digits
Accuracy kWHr < 2 kWHr
±0.08 kWHr
All Watts /VA /VAR /PF measurements Frequency range
DC and 15 Hz to 1 kHz
All Watts /VA /VAR /PF measurements Current range
10 A to 1400 A rms
All Watts /VA /VAR /PF measurements
Voltage range: 1 V to 825 V rms || Maximum input: 825 V rms / 1400 A rms
All Watts /VA /VAR /PF measurements Maximum overload
1000 V rms / 10,000 A All measurements DC and 15 Hz to 1 kHz. Maximum overload 10,000 A or rms x frequency < 400,000
Accuracy
15 to 22 Hz ±0.5% rdg40 Hz to 70 Hz ±0.5% rdg15 Hz to 1000 Hz ±1% rdg
Current range
10 A to 1400 A rms
Voltage range
1 V to 825 V rms

Electrical safety

Maximum safe working voltages
Safety IEC 61010-1 600 V CAT IV double or reinforced insulation, pollution degree 2Protection IP40; EN60529
Current measurement
600 VAC rms or DC between uninsulated conductor and ground
Voltage measurement
600 VAC rms or DC between either input terminal and ground, or 825 V between energized phase voltages (delta power config.)

Specifications

Display
Color transmissive LCD 320 x 240 pixels (70 mm diagonal) with 2 level backlight
Power supply
Battery type 1.5 V Alkaline AA MN 1500 or IEC LR6 x 6
Battery life typically
> 10 hours (backlight on full)> 12 hours (backlight reduced)
Battery eliminator  Input
110/230 V 50/60 Hz
Battery eliminator  Output
15 VDC, 300 mA

EMC

Emission
IEC/EN 61326-1:1997 A
Immunity
IEC/EN 61326-1:1997 Annex C Performance Criterion B

Harmonics

THD (Total Harmonic Distortion) 1% ≤ THD < 100%
±3% rdg ±5 digits
THD (Total Harmonic Distortion) 100% ≤ THD < 600%
±5% rdg ±5 digits
THD (Total Harmonic Distortion) Resolution
0.1%
DF (Distortion Factor) 1% ≤ DF < 100%
±3% rdg ±5 digits
DF (Distortion Factor) Resolution
0.1%
DF (Distortion Factor)
H02 ≤ Vharm < H13: ±5% ±2 digits || H13 ≤ Vharm ≤ H30: ±10% ±2 digits
Measuring range
0 to 1650 kW DC or 1200 kW AC || 4 kW, 40 kW, 400 kW, 1650 kW || 0 to 1650 kVA DC or 1200 kVA AC || 0 to 1250 kVAR
Resolution
1 W in 4 kW10 W in 40 kW100 W in 400 kW1 kW in 1200 kW || 1 VA in 4 kVA10 VA in 40 kVA100 VA in 400 kVA1 kVA in 1200 kVA || 1 VAR in 4 kVAR10 VAR in 40 kVAR100 VAR in 400 kVAR1 kVAR in 1200 kVAR
Accuracy
2.5% rdg ±5 digitsW1Ø < 2 kW ±0.08 kWW3Ø < 4 kW ±0.25 kW || VA > 2 kVA: 2.5% rdg ±5 digits || VA < 2 kVA: ±0.08 kVA || VAR > 4 kVAR: ±2.5% rdg ±5 digits || VAR < 4 kVAR: ±0.25 kVAR
Autorange facility
4 kVA, 40 kVA, 400 kVA, 1650 kVA || 4 kVAR, 40 kVAR, 400 kVAR, 1200 kVAR
Power factor range
0.3 < PF < 0.99

Inrush current function

Ranges
40 A, 400 A, and 2000 A
Resolution
10 mA in 40 A range100 mA in 400 A range1 A in 2000 A range
Accuracy I > 10 A
±5% rdg ±1 pixel
Accuracy I < 10 A
±0.5 A
Accuracy
All measurements DC and 15 Hz to 1 kHz
Maximum overload
Maximum overload 10,000 A or rms x frequency < 400,000Amps rms is a true-rms measurement (AC + DC)
Capture time
1 s, 3 s, 10 s, 30 s, 100 s, and 300 s
Maximum sampling rate
15.625 kHz

Ambient conditions (for indoor use only)

Reference conditions
All accuracies stated at 23°C ±1°C (73.4°F ±1.8°F)
Operating temperature
0°C to 50°C (32°F to 122°F)
Temperature coefficient of current
≤ ±0.15% of rdg per °C
Temperature coefficient of voltage
≤ ±0.15% of rdg per °C
Maximum relative humidity
80% for temperatures up to 31°C (87°F) decreasing linearly to 50% relative humidity at 40°C (104°F)
Maximum operating altitude
2000 m

Documents

Data Sheet

Download