Fluke
FLUKE 3540 FC KIT
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Electromagnetic compatibility (EMC)
- International
- IEC 61326-1: Industrial
- Korea (KCC)
- Class A Equipment (Industrial Broadcasting & Communication Equipment)
- USA (FCC)
- 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Calculated min/max values times
- Voltage
- Full cycle RMS (20 ms at 50 Hz, 16.7 ms at 60 HZ)
- Current
- Half cycle RMS (10 ms at 50 Hz, 8.3 ms at 60 Hz)
- Power
- 200 ms
WiFi
- Supported modes
- Direct connection and connection to infrastructure
- Security
- WPA2-AES with pre-shared key
Single and three-phase topologies
- Wiring configurations
- 1-Φ, 1-Φ IT, Split-phase, 3-Φ wye, 3-Φ wye IT, 3-Φ wye balanced, 3-Φ delta, 3-Φ Aron/Blondel (2-element delta), 3-Φ delta open leg, 3-Φ high leg delta, 3-Φ delta balanced. Currents only (load studies)
Current inputs
- Number of inputs
- 3, mode selected automatically for attached sensor
- Current sensor output voltage Clamp
- 500 mVrms / 50 mVrms; CF 2.8
- Current sensor output voltage Rogowski coil
- 150 mVrms/15 mVrms at 50 Hz, 180 mVrms/18 mVrms at 60 Hz; CF 4; all at nominal probe range
- Bandwidth (-3 dB)
- 42.5 Hz to 3.5 kHz
- Scaling
- 1:1 and variable
Environmental specifications
- Operating temperature
- 0 °C to +45 °C (+32 °F to +113 °F)
- Storage temperature
- <20 °C to +60 °C (-4 °C to +140 °F), with battery: -20 °C to +50 °C (-4 °F to +122 °F)
- Operating humidity
- <10 °C (<50 °F) non condensing || +10 °C to +30 °C (+50 °F to +86 °F) ≤95 % || +30 °C to +40 °C (+86 °F to +104 °F) ≤75 % || +40 °C to +45 °C (+104 °F to +113 °F) ≤45 %
- Operating altitude
- 2000 m (6,500 ft) (up to 4,000 m derate to 1000 V CAT II/600 V CAT III/300 V CAT IV)
- Storage altitude
- 12,000 m (39,000 ft)
- IP Rating
- IEC 60529:IP50, in connected condition with protection caps in place
- Vibration
- MIL-T-28800E, Type 3, Class III, Style B
Wireless radio with adapter
- Frequency range
- 2412 MHz to 2462 MHz
- Output power
- <100 mW
Data acquisition
- Resolution
- 16-bit synchronous sampling
- Sampling frequency
- 10.24 kHz at 50/60Hz, synchronized to mains frequency
- Input signal frequency
- Mains 50/60 Hz (42.5 to 69 Hz)
- Data storage
- Internal flash memory (not user replaceable)
- Memory size
- Typical 1 offline logging session of 1 week with 1 second intervals. The number of possible logging sessions and logging period depends on user requirements.
- Measured parameters
- Voltage, current, frequency, THD V, THD A, power, power factor, fundamental power, DPF
- Averaging interval
- 1 s
- Total harmonic distortion
- THD for voltage and current is calculated on 25 harmonics
Interfaces
- USB-A
- Firmware updates, max. supply current: 120 mA
Voltage inputs
- Number of inputs
- 4 (3 phases and neutral)
- Maximum input voltage
- 1000 Vrms (1700 Vpk) phase to neutral
- Input impedance
- 10 MΩ each phase to neutral
- Bandwidth
- 42.5 Hz to 3.5 kHz
- Scaling
- 1:1, variable
Power supply
- Voltage range
- Nominal 100 V to 500 V (85 V min to 550 V max) using safety plug input
- Mains power
- Nominal 100 V to 240 V (85 V min to 265 V max) using IEC 60320 C7 input
- Power consumption
- Maximum 50 VA (max. 15 VA when powered using IEC 60320 input)
- Standby power
- <0.3 W only when powered using IEC 60320 input
- Efficiency
- ≥68.2 % (in accordance with energy efficiency regulations)
- Mains frequency
- 50/60 Hz ±15 %
- Battery power
- Li-ion 3.7 V, 9.25 Wh, customer-replaceable
- On-battery runtime
- Up to 4 hr (up to 5.5 hr in energy saving mode)
- Charging time
- <6 hr
Safety
- IEC 61010-1
- IEC mains input: Overvoltage Category II, Pollution Degree 2 || Voltage terminals: Overvoltage Category IV, Pollution Degree 2
General specifications
- Color LCD display
- 4.3-inch active matrix color TFT, 480 pixels x 272 pixels, resistive touch panel
- Warranty
- 3540 FC and built-in power supply: 2 years (battery not included)
- Warranty Accessories
- 1 year
- Calibration cycle
- 2 years
- Dimensions (WxHxD 3540 FC
- 19.8 x 16.7 x 5.5 cm (7.8 x 6.6 x 2.2 in)
- Dimensions (WxHxD Detachable power supply
- 13.0 x 13.0 x 4.5 cm (5.1 x 5.1 x 1.8 in)
- Dimensions (WxHxD 3540 FC with power supply attached
- 19.8 cmx 16.7 x 9 cm (7.8 x 6.6 x 4.0 in)
- Weight 3540 FC
- 1.1kg (2.5 lb)
- Weight
- 1.1kg (2.5 lb): Power supply
- Tamper protection
- Kensington lock
Documents
Data Sheet
DownloadOther Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther