Fluke

FLUKE 724

FLUKE 724
FLUKE 724
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

RTDs and Thermocouples

Measure accuracy NI-120
0.2°C
Measure accuracy PT-100 (385)
0.33°C
Measure accuracy PT-100 (393)
0.3°C
Measure accuracy PT-100 (JIS)
0.3°C
Measure accuracy PT-200 (385)
0.2°C
Measure accuracy PT-500 (385)
0.3°C
Measure accuracy PT-1000 (385)
0.2°C
Measure accuracy Resolution
0.1°C || J, K, T, E, L, N, U: 0.1°C, 0.1°F B, R, S: 1°C, 1°F
Measure accuracy J
0.7°C
Measure accuracy K
0.8°C
Measure accuracy T
0.8°C
Measure accuracy E
0.7°C
Measure accuracy R
1.8°C
Measure accuracy S
1.5°C
Measure accuracy B
1.4°C
Measure accuracy L
0.7°C
Measure accuracy U
0.75°C
Measure accuracy N
0.9°C
Measure accuracy XK
0.6°C
Measure accuracy BP
1.2°C
Source accuracy NI-120
0.2°C
Source accuracy PT-100 (385)
0.33°C
Source accuracy PT-100 (393)
0.3°C
Source accuracy PT-100 (JIS)
0.3°C
Source accuracy PT-200 (385)
0.2°C
Source accuracy PT-500 (385)
0.3°C
Source accuracy PT-1000 (385)
0.2°C
Source accuracy Resolution
0.1°C || J, K, T, E, L, N, U: 0.1°C, B, R, S: 1°C
Source accuracy
Accuracy stated for 4-wire measurement.
Source accuracy J
0.7°C
Source accuracy K
0.8°C
Source accuracy T
0.8°C
Source accuracy E
0.7°C
Source accuracy R
1.4°C
Source accuracy S
1.5°C
Source accuracy B
1.4°C
Source accuracy L
0.7°C
Source accuracy U
0.75°C
Source accuracy N
0.9°C
Source accuracy XK
0.6°C
Source accuracy BP
1.2°C

Source Accuracy

Voltage DC
100.00 mV: 0.02% + 2 counts || 10.000 V: 0.02% + 2 counts || -10.00 mV to 75.00 mV: 0.025 % + 1 count (via TC connector)
Resistance
15.0 to 400.0 Ω: 0.15 Ω (exc. current 0.15 to 0.5 mA), 0.1 Ω (exc. current 0.5 to 2 mA) || 401 to 1500 Ω: 0.5 Ω (excitation current 0.05 to 0.8 mA) || 1500 to 3200 Ω: 1 Ω (excitation current 0.05 to 0.4 mA)

Mechanical and General Specifications

Size
96 x 200 x 47 mm
Weight
650 g
Batteries
Four AA alkaline batteries
Warranty
Three years
Battery life
25 hours typical
Shock and vibration
Random, 2 G, 5-500 Hz

Measurement Accuracy

Voltage DC
30.000 V: 0.02% + 2 counts (upper display) || 20.000 V: 0.02% + 2 counts (lower display) || 100.00 mV: 0.02% + 2 counts || -10.00 mV to 75.00 mV: 0.025% + 1 count (via TC connector)
Current DC
24.000 mA: 0.02% + 2 counts
Resistance
0.0 to 400.0 Ω: 0.1 Ω (4-wire), 0.15 Ω (2- and 3-wire) || 401 to 1500 Ω: 0.5 Ω (4-wire), 1 Ω (2- and 3-wire) || 1500 to 3200 Ω: 1 Ω (4-wire), 1.5 Ω (2- and 3-wire)

Specifications

Ramp functions Source functions
Voltage, current, resistance, frequency, temperature
Ramp functions Ramps
Slow ramp, Fast ramp, 25% step-ramp
Loop power function
Voltage: 24 V
Loop power function Accuracy
10%
Loop power function Maximum current
22 mA, short circuit protected
Step functions Source functions
Voltage, current, resistance, frequency, temperature
Step functions Steps
25% of range, 100% of range

Safety Specifications

Safety rating
CSA C22.2 No. 1010.1:1992
EMC
EN50082-1:1992 and EN55022:1994 Class B

Environmental Specifications

Operating temperature
-10°C to 55°C
Storage temperature
-20°C to 71°C
Humidity (without condensation) 90%
10°C to 30°C
Humidity (without condensation) 75%
30°C to 40°C
Humidity (without condensation) 45%
40°C to 50°C
Humidity (without condensation) 35%
50°C to 55°C

Documents

Data Sheet

Download