Measured Specifications

Temperature Range
-20°C to 50°C (-5°F to 122°F)
Temperature Display resolution
0.1°C (0.1°F)
Temperature Accuracy
±0.9°C / ±1.62°F from 40°C to 60°C±0.5°C / ±1.00°F from 5°C to 40°C±1.1°C / ±1.98°F from -20°C to 5°C
Relative humidity Range
10% to 90% RH, non-condensing
Relative humidity Display Resolution
1%
Relative humidity Accuracy
±2% RH (10% RH to 90% RH)
Air velocity Range
50.0 fpm to 3000 fpm0.25 m/sec to 15 m/sec
Air velocity Display Resolution
1 fpm (0.005 m/sec)
Air velocity Accuracy
±4% or 4 fpm1±4% or 0.02 m/sec1 whichever is greater || 1. Accuracy specification only valid for velocity readings above 50 fpm.
C0 Range
0 to 500 ppm
C0 Display Resolution
1 ppm || 1 ppm
C0 Accuracy
±5% or ±3 ppm, whichever is greater, @ 20°C and 50% RH || Warm up time 1 min (5 minutes for full specification) 2.75% + 75 ppm
C02 Range
0 to 5000 ppm

Calculated Specifications

Dew point temperature Range
-44°C to 50°C, (-47°F to 122°F)
Dew point temperature Display Resolution
0.1°C (0.1°F)
Dew point temperature Accuracy
±1°C when temp: -20°C to 50°C RH: 40% to 90%±2°C when temp: -20°C to 50°C RH: 20% to 40%±4°C when RH: 10% to 20%
Wet bulb temperature Range
-16°C to 50°C, (3°F to 122°F)
Wet bulb temperature Display Resolution
0.1°C, (0.1°F)
Wet bulb temperature Accuracy
±1.2°C when RH: 20% to 90% temp: -20°C to 60°C±2.1°C when RH: 10% to 20%
Volume flow rate (in a duct) Range
0 to 3,965 M3/m, (0 to 140,000 cfm)
Volume flow rate (in a duct) Display Resolution
0.001 M3/min, (1 cfm)
Volume flow rate (in a duct) Accuracy
N/A: The volume flow calculation will be a simple average of the data points times the duct area
% outside air (based on temperature) Range
0 to 100%
% outside air (based on temperature) Display Resolution
0.1
% outside air (based on CO2) Range
0 to 100%
% outside air (based on CO Display Resolution
0.1% N/A

General Specifications

Operating and storage temperature
-20°C to 50°C (-4°F to 122°F)
Humidity
10% to 90% (non-condensing)
Altitude
Up to 2000 m (6562 ft)
Shock and vibration
MIL-PRF-28800F: Class 2
Multi-language interface
English, French, Spanish, Portuguese and German
Battery
Rechargeable Li-Ion (primary), three-AA (backup)
Data logging
25,000 records (continuous), 99 records (discrete)
Warranty
Two-years