Measured Specifications
- Temperature Range
- -20°C to 50°C (-5°F to 122°F)
- Temperature Display resolution
- 0.1°C (0.1°F)
- Temperature Accuracy
- ±0.9°C / ±1.62°F from 40°C to 60°C±0.5°C / ±1.00°F from 5°C to 40°C±1.1°C / ±1.98°F from -20°C to 5°C
- Relative humidity Range
- 10% to 90% RH, non-condensing
- Relative humidity Display Resolution
- 1%
- Relative humidity Accuracy
- ±2% RH (10% RH to 90% RH)
- Air velocity Range
- 50.0 fpm to 3000 fpm0.25 m/sec to 15 m/sec
- Air velocity Display Resolution
- 1 fpm (0.005 m/sec)
- Air velocity Accuracy
- ±4% or 4 fpm1±4% or 0.02 m/sec1 whichever is greater || 1. Accuracy specification only valid for velocity readings above 50 fpm.
- C0 Range
- 0 to 500 ppm
- C0 Display Resolution
- 1 ppm || 1 ppm
- C0 Accuracy
- ±5% or ±3 ppm, whichever is greater, @ 20°C and 50% RH || Warm up time 1 min (5 minutes for full specification) 2.75% + 75 ppm
- C02 Range
- 0 to 5000 ppm
Calculated Specifications
- Dew point temperature Range
- -44°C to 50°C, (-47°F to 122°F)
- Dew point temperature Display Resolution
- 0.1°C (0.1°F)
- Dew point temperature Accuracy
- ±1°C when temp: -20°C to 50°C RH: 40% to 90%±2°C when temp: -20°C to 50°C RH: 20% to 40%±4°C when RH: 10% to 20%
- Wet bulb temperature Range
- -16°C to 50°C, (3°F to 122°F)
- Wet bulb temperature Display Resolution
- 0.1°C, (0.1°F)
- Wet bulb temperature Accuracy
- ±1.2°C when RH: 20% to 90% temp: -20°C to 60°C±2.1°C when RH: 10% to 20%
- Volume flow rate (in a duct) Range
- 0 to 3,965 M3/m, (0 to 140,000 cfm)
- Volume flow rate (in a duct) Display Resolution
- 0.001 M3/min, (1 cfm)
- Volume flow rate (in a duct) Accuracy
- N/A: The volume flow calculation will be a simple average of the data points times the duct area
- % outside air (based on temperature) Range
- 0 to 100%
- % outside air (based on temperature) Display Resolution
- 0.1
- % outside air (based on CO2) Range
- 0 to 100%
- % outside air (based on CO Display Resolution
- 0.1% N/A
General Specifications
- Operating and storage temperature
- -20°C to 50°C (-4°F to 122°F)
- Humidity
- 10% to 90% (non-condensing)
- Altitude
- Up to 2000 m (6562 ft)
- Shock and vibration
- MIL-PRF-28800F: Class 2
- Multi-language interface
- English, French, Spanish, Portuguese and German
- Battery
- Rechargeable Li-Ion (primary), three-AA (backup)
- Data logging
- 25,000 records (continuous), 99 records (discrete)
- Warranty
- Two-years
Documents
Data Sheet
DownloadOther Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther