Fluke Ti125 Infrared Camera Specifications

Centerbox (MIN/AVG/MAX)
Yes
Extended warranty and service plans
1. Assumes 50% brightness of LCD
Minimum span in manual mode
2.5°C
Battery (field-replaceable, rechargeable)
Two
Ingress protection (IP) rating (IEC 60529)
IP 54
Multi-mode video recording (standard avi w/ mpeg encoding)
Yes (AVI with MPEG encoding, up to 5 minutes)
Spectral band
7.5 μm to 14μm (long wave)
Minimum span in auto mode
5°C
Size
28.4 x 8.6 x 13.5 cm (11.2 x 3.4 x 5.3 in)
External battery charging base
Yes
Transmission correction
Yes
Hot/cold markers
Yes
Level and span control
Manual and auto
Temperature measurement range (not calibrated below -10°C)
-20°C to +350°C (-4°F to +662°F)
Visible camera
2 megapixel industrial-grade
Drop test
2 meter (6.5 feet)
EMI, RFI, EMC
EN61326-1; FCC Part 5
Multi-mode video recording (radiometric .Is3)
Yes, radiometric .is3 for approx. 2.5 to 5 minutes depending upon thermal scene
C Tick
IEC/EN 61326-1
Ultra Contrast™ palettes
Blue-red, grayscale, inverted grayscale, high-contrast, hot metal, ironbow, amber, inverted amber
Memory review
Thumbnail review
Safety standards
CSA (US and CAN): C22.2 No. 61010-1-04, UL: UL STD 61010-1 (2nd Edition), ISA: 82.02.01
Capture or refresh rate
9 Hz or 30 Hz versions
IR-Fusion® technology
PIP, FULL IR, FULL VISIBLE, AutoBlend™
IFOV (spatial resolution)
3.39 mRad
Minimum IR focus distance
15.25 cm (6 in)
IR-PhotoNotes™ annotation system
Yes (3 images)
Memory storage
2 GB SD memory card
Voice annotation (audio)
Yes (60 seconds) per image
Background (reflected) compensation
Yes
IR resolution (FPA size)
160 x 120 FPA Uncooled Microbolometer
Standard warranty period
Two-years
Charging power supply
Yes
Vibration and shock
2G, IEC 68-2-26 and 25G, IEC 68-2-29
Laser pointer
Yes
Recommended calibration cycle
Two-years
Operating humidity
Operating and storage 10% to 95%, non-condensing
Multi-mode video output
Streaming USB video output (infrared, visible and IR-Fusion modes)
Battery life
4+ hours (each)1
Weight
0.726 kg (1.6 lb)
User manuals
Czech, English, Finnish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, Turkish, Dutch, and Hungarian
Operating temperature range
-10°C to +50°C (14°F to 122°F)
NETD (thermal sensitivity)
≤ 0.10°C at 30°C target temp (100 mK) 0.10°C at 30°C target temp (100 mK)
Color alarms
High temperature, low temperature, isotherm
Standard palettes
Blue-red, grayscale, inverted grayscale, high-contrast, hot metal, ironbow, amber, inverted amber
Emissivity correction
Yes
Torch
Yes
LCD display
3.5 inch diagonal (portrait format)
Temperature measurement accuracy
±2°C or 2% (at 25°C nominal, whichever is greater)
Direct download capability
Mini USB download direct to PC
CNX wireless enabled
Yes
Extended warranty and service plans
Yes
User definable spot markers
Three on camera and in SmartView®
Electronic (cardinal) compass
Yes
Storage temperature range
-20°C to +50°C (-4°F to 122°F)
Multifunction card reader
Included
Minimum automatic parallax correction
~18-22 inches
Focus mechanism
IR-OptiFlex™ focus system
FOV (field of view)
22.5°H x 31°V

Fluke CNX i3000 iFlex AC Wireless Current Module Specifications

Pollution degree
2
Memory record
up to 65,000 readings
Operating humidity
90% at 35°C, 75% at 40°C, 45% at 50°C
RF communication range
20 Meters
Log rate/interval
1 sec minimum/adjustable by PC or front panel
Resolution
0.1A to 999.9, 1A from 1000 to 2500
EMC
EN 61326-1:2006
Ingress Protection (IP) rating
IP42
Range
2500 A AC
Accuracy
3% ± 5 digits
Weight
.22 kg (8 oz)
Size (H x W x D)
16.5 x 6.35 x 3.56 cm (6.5 x 2.5 x 1.4 in)
Battery type
2 AA, NEDA 15 A, IEC LR6
Unbound listen interval
5 seconds
Battery life
400 hours
RF communications
2.4 GHZ ISM Band
Operating temperature
-10°C to +50°C
Crest factor (50 Hz/60 Hz)
3.0 at 1100 A, 2.5 at 1400 A, 1.42 at 2500 A, add 2% for C.F. > 2
Safety compliance
EN/IEC 61010-1:2010 to 1000 V Measurement Category (CAT) III 600 V Measurement Category (CAT) IV EN/IEC 61010-2-030:2010 EN/IEC 610101-2-031:2002 EN/IEC 61010-2-032:2002
Storage temperature
-40°C to +60°C
Safety rating
CAT IV 600 V, CAT III 1000 V
Temperature coefficient
Add 0.1 x (specified accuracy)/°C (<18°C or >28°C)
Jaw opening
25.4 cm (10 in) coil
Display
3-1/2 digits, LCD w/ backlight
Certifications
CSA, FCC T68-FWCS IC:6627A-FWCS