Fluke

Fluke i30

Fluke i30
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
A total of 3 Parts In-Stock from 1 Distributor

Electrical Specifications

Specified current range
30 mA to 30 A DC, 30 mA to 20 A AC rms
Usable current range
5 mA to 30 A DC, 30 mA to 20 A AC rms
Crest Factor
1.4 in
Output sensitivity
100 mV/A
Accuracy (at +25°C)
±1% of reading ±2 mA
Resolution
±1 mA
Load impedance
> 10 k Ohms and ≤ 100pF
Conductor position sensitivity
±1% relative to center reading
Frequency range
DC to 20 kHz (-0.5 dB)
Temperature coefficient
±0.01% of reading/°C
Power supply
9 V Alkaline, MN1604/PP3, 30 hours, low battery indicator
Working voltage (see Safety Standards section)
300 V AC rms or DC

General Specifications

Maximum conductor size
19 mm diameter
Output connection
4 mm safety connector
Output zero
Manual adjust via thumbwheel
Cable length
1.5 meters
Operating temperature range
0°C to +50°C
Storage temperature range (with battery removed)
-20°C to +85°C
Operating humidity
15% to 85% (non-condensing)
Weight
250 g
Safety
Use of the probe on uninsulated conductors is limited to 300 V ac rms or dc andfrequencies below 1 kHz.
EMC Compatibility
IEC 61326-1: Portable Electromagnetic Environment

Documents

Data Sheet

Download