Fluke

I30S

Fluke i30s AC/DC Current Clamp is used in conjunction with oscilloscopes for accurate non-intrusive current measurement. Contact us for more information.
I30S
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
€819.23
1
Payment methods:
A total of 13 Parts In-Stock from 2 Distributors

Electrical specifications

Usable current range
5 mA to 30 A DC, 30 mA to 20 A AC rms
Output sensitivity
100 mV/A
Conductor position sensitivity
±1% relative to center reading
Resolution
±1 mA
Working voltage (see Safety Standards section)
300 V AC rms or DC
Temperature coefficient
±0.01% of reading / °C
Specified current range
30 mA to 30 A DC, 30 mA to 20 A AC rms
Power supply
9 V Alkaline, MN1604/PP3, 30 hours, low battery indicator
Frequency range
DC to 100 kHz (-0.5 dB)
Load impedance
> 100 kΩ
Accuracy (at +25°C)
±1% of reading ±2 mA
Phase shift below 1 kHz
< 2°
Crest factor
1.4 in

General Specifications

Operating humidity
15% to 85% (non-condensing)
Cable length
2 m
EMC standards
EN 61326: 1998 +A1, A2, and A3
Safety standards
BS EN 61010-2-032: 2002
Maximum conductor size
19 mm diameter
Output zero
Manual adjust via thumbwheel
Operating temperature range
0°C to +50°C
Safety standards
BS EN 61010-031: 2002
Safety standards
BS EN 61010-1: 2001
Safety standards
Use of the probe on uninsulated conductors is limited to 300 V AC rms or DC and frequencies below 1 kHz
Output connection
Safety BNC connector, supplied with safety 4 mm adapter
Weight
250 g
Storage temperature range (with battery removed)
-20°C to +85°C
Safety standards
300 Vrms, Category III, Pollution Degree 2