Image Presentation

Full screen (PIP off)
100% IR displayed in center 640 x 480 LCD
Palettes
Ironbow, blue-red, high contrast, grey
Picture-In-Picture (PIP)
100% IR displayed in center 320 x 240 pixels
Minimum span (in manual mode)
5°C (9°F)
IR-Fusion® information
Full infrared or picture-in-picture
Palettes
Ironbow, blue-red, high contrast, grey
Level and span
Smooth auto-scaling and manual scaling of level and span
Minimum span (in auto mode) Fast Auto/Manual Range Toggle Fast Auto Rescale
10°C (18°F)

Temperature

Temperature measurement range (not calibrated below -10°C)
-20°C to +250°C (-4°F to + 482°F)
Temperature measurement accuracy
±2°C or 2% (at 25°C nominal, whichever is greater)

Image Capture and Data Storage

Storage medium
SD memory card (2 GB memory card will store at least 1200 fully radiometric (.is2) IR and linked visual images each or 3000 basic (.bmp) IR images)
Export file formats w/SmartView™ software
JPEG, BMP, GIF, PNG, TIFF, WMF, EXIF, and EMF
File formats
Non-radiometric (.bmp) or fully-radiometric (.is2) No analysis software required for non-radiometric (.bmp) files

General Specifications

Battery life
Three to four hours continuous use (assumes 50% brightness of LCD)
Software
SmartView® full analysis and reporting software included
Shock
25 G, IEC 68-2-29 {2 m (6.5 ft) drop, 5 sides}
Electromagnetic compatibility
EMC directive: EN61326-1 C-Tick: IEC/EN 61326 US FCC: CFR 47, Part 15 Class A
Supported languages
Czech, English, Finnish, French. German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, Turkish
IP rating
IP54
Operating temperature
-10°C to +50°C (14°F to 122°F)
Relative humidity
10% to 95% non-condensing
Batteries
Internal rechargeable battery pack (included)
Display
9.1 cm (3.6 in) diagonal landscape color VGA (640 x 480) LCD with backlight (selectable bright or auto)
Power saving
Sleep mode activated after five minutes of inactivity, automatic power off after 20 minutes of inactivity
Safety standards
CE Directive: IEC/EN 61010-1 2nd Edition Pollution Degree 2
Controls and adjustments
User selectable temperature scale (°C/°F) Language selection Time/Date set
Weight
1.2 kg (2.65 lb)
Warranty
Two-years
Storage temperature
-20°C to +50°C (-4°F to 122°F) without batteries
Vibration
2 G, IEC 68-2-29
Dimensions (H x W x L)
0.27 x 0.13 x 0.15 m (10.5 x 5 x 6 in)
Battery charge time
Two hours for full charge
AC operation/charging
AC adapter/charger (110 V AC to 220 V AC, 50 Hz to 60 Hz). Charges battery while imager is operating. Universal AC mains adapters included.
Calibration cycle
Two-years (assumes normal operation and normal aging)

Imaging Performance

Spatial resolution (IFOV)
2.5 mRad
Field of view
23° x 17°
Visual camera
640 x 480 resolution
Infrared spectral band
7.5 μm to 14 μm
Image frequency
9 Hz refresh rate
Infrared lens type
20 mm F = 0.8 lens
Thermal sensitivity (NETD)
≤ 0.13°C at 30°C target temp. (130 mK)
Detector type
160 x 120 focal plane array, uncooled microbolometer
Focus
Manual
Minimum focus distance
Thermal lens: 15 cm (6 in) Visible (visual) light lens: 46 cm (18 in)