Ti32
Fluke Ti32 combines high resolution and IR-Fusion technology to create detailed images. Check out its robust specifications to meet an array of needs.
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
General Specifications
- Safety standards
- CSA (US and CAN): C22.2 No. 61010-1-04, UL: UL STD 61010-1 (2nd Edition), ISA: 82.02.01
- US FCC
- CFR 47, Part 15 Class B
- Supported languages
- Czech, English, Finnish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish
- Enclosure rating
- IP54 (protected against dust, limited ingress; protection against water spray from all directions)
- Electromagnetic compatibility
- Meets all applicable requirements in EN61326-1:2006
- C Tick
- IEC/EN 61326-1
- Warranty
- Two-years (standard)
- Power saving
- Sleep mode activated after five minutes of inactivity, automatic power off after 30 minutes of inactivity
- Weight (battery included)
- 1.05 kg (2.3 lb)
- Shock
- 25 g, IEC 68-2-29
- Batteries
- Two lithium ion rechargeable smart battery packs with five-segment LED display to show charge level
- AC battery charging
- Two-bay AC battery charger (110 V AC to 220 V AC, 50/60 Hz) (included), or in-imager charging. AC mains adapters included. Optional 12 V automotive charging adapter.
- AC operation
- AC operation with included power supply (110 V AC to 220 V AC, 50/60 Hz). AC mains adapters included.
- Recommended calibration cycle
- Two-years (assumes normal operation and normal aging)
- Operating temperature
- -10°C to +50°C (14°F to 122°F)
- Drop
- 2 m (6.5 ft) with standard lens
- Dimensions (H x W x L)
- 27.7 x 12.2 x 17.0 cm (10.9 x 4.8 x 6.7 in)
- Storage temperature
- -20°C to +50°C (-4°F to 122°F) without batteries
- Controls and adjustments
- User selectable temperature scale (°C/°F) Language selection Time/Date set Emissivity selection Reflected background temperature compensation Transmission correction User selectable hot spot and cold spot, and center point on the image (other custom markers and shapes in SmartView® software) High temperature alarm User selectable backlight: "Full Bright" or "Auto" Information display preference
- Vibration
- 0.03 g2/Hz (3.8 grms), IEC 68-2-6
- Battery charge time
- 2.5 hours to full charge
- Battery life
- Four+ hours continuous use per battery pack (assumes 50% brightness of LCD)
- Display
- 9.1 cm (3.7 in) diagonal landscape color VGA (640 x 480) LCD with backlight and clear protective cover
- Software
- SmartView® full analysis and reporting software included
- Relative humidity
- 10% to 95% non-condensing
Temperature
- Temperature measurement accuracy
- ±2°C or 2% (at 25°C nominal, whichever is greater)
- On-screen emissivity correction
- Yes
- On-screen transmission correction
- Yes
- Temperature measurement range (not calibrated below -10°C)
- -20°C to +600°C (-4°F to +1112°F)
- On-screen reflected background temperature compensation
- Yes
IR-Fusion Information
- Picture-in-picture (PIP)
- Three levels of on-screen IR blending displayed in center of LCD
- Full screen infrared
- Three levels of on-screen IR blending displayed in center of LCD
- Color alarms (temperature alarms)
- High-temperature alarm (user-selectable)
- Automatically aligned (parallax corrected) visual and IR blending
- Yes
Image Capture and Data Storage
- Voice annotation
- 60 seconds maximum recording time per image; reviewable playback on imager
- Image capture, review, save mechanism
- The Ti32 allows user to adjust palette, blending, level, span, IR-Fusion® mode, emissivity, and reflected background temperature compensation, and transmission correction on a captured image before it is stored.
- Storage medium
- One-handed image capture, review, and save capability
- File formats
- SD Memory Card (2 GB memory card will store at least 1200 fully radiometric (.is2) IR and linked visual images each with 60 seconds voice annotations, or 3000 basic bitmap (.bmp) images, or 3000 jpeg (.jpeg) images; transferrable to PC via included multi-format USB card reader
- Export file formats w/SmartView® software
- Non-radiometric (.bmp) or (.jpeg) or fully-radiometric (.is2) No analysis software required for non-radiometric (.bmp and .jpeg) files