Fluke

TiX560 60 Hz

The largest 5.7in touchscreen LCD for a 320x240 IR camera, easy target navigation w/ a 180⁰ rotating lens & LaserSharp® Auto Focus let you instantly capture an in-focus image.
TiX560 60 Hz
TiX560 60 Hz
TiX560 60 Hz
TiX560 60 Hz
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Key Features

Level and span
Smooth auto and manual scaling
Frame rate
60 Hz or 9 Hz versions
Field of view
46 °H x 34 °V
AutoBlend™ mode
Yes
Image sharpening
Yes
LED light (torch)
Yes
Minimum span (in manual mode)
2.0 °C (3.6 °F)
Field of view
24 °H x 17 °V
Minimum focus distance
15 cm (approx. 6 in)
Minimum focus distance
45 cm (approx. 18 in)
Detector resolution
320 x 240 (76,800 pixels)
Laser pointer
Yes
SuperResolution*
On camera and in software
Picture-In-Picture (PIP)
Yes
Thermal sensitivity (NETD)
≤ 0.045 °C at 30 °C target temp (45 mK)
LaserSharp® Auto Focus
Yes, for consistently in-focus images. Every. Single. Time.
Fast auto toggle between manual and auto modes
Yes
Fluke Connect™ app compatible
Yes (where available)
Streaming video (remote display)
Via USB or WiFi
Minimum span (in auto mode)
3.0 °C (5.4 °F)
Minimum focus distance
15 cm (approx. 6 in)
Touchscreen adjustable level / span
Yes. Span and level can be easy and quickly set by simply touching the screen.
Rugged, ergonomic design for one-handed use
Rotatable (articulating lens) >180 degrees
IFOV with standard lens (spatial resolution)
1.31 mRad
Touchscreen display (capacitive)
14.4 cm (5.7 in) diagonal landscape color VGA (640 x 480) LCD with backlight
Field of view
12 °H x 9 °V
IFOV with optional telephoto lens
0.65 mRad
Filter mode (NETD improvement)
≤ 0.03 °C at 30 °C target temp (30 mK)
Wireless connectivity
Yes, to PC, iPhone® and iPad® (iOS 4s and later), Android™ 4.3 and up, and WiFi to LAN (where available)
IFOV with optional wide-angle lens
2.62 mRad
Continuous AutoBlend™
Set AutoBlend™ level across continuum
Fluke Connect™ tool compatible
Yes (where available). Connects wireless to select Fluke Connect™ enabled tools. Five simultaneous connections supported.
Fast auto-rescale in manual mode
Yes
Built-in digital camera (visible light)
5 megapixel industrial performance
Advanced manual focus
Yes
IR-Fusion® technology
Yes
Laser distance meter
Yes, calculates distance to the target for precisely focused images and displays distance on screen
Digital zoom
2x, 4x, 8x

Data Storage and Image Capture

Text annotation
Yes
Remote control and operation (for special and advanced applications)
Yes
Post-capture image editing (on camera)
Yes. Conduct on camera analysis for in-field results.
File formats
Non-radiometric (.bmp) or (.jpeg) or fully radiometric (.is2); no analysis software required for non-radiometric (.bmp, .jpg and .avi) files
Auto capture (temperature and interval)
Yes
IR-PhotoNotes™
Yes
Software
SmartView® software, Fluke Connect™ (where available), and SmartView® Mobile App - full analysis and reporting software
Advanced text annotation
Yes. Including standard shortcuts as well as user programmable options.
Voice annotation
60 seconds maximum recording time per image; reviewable playback on camera; Bluetooth headset provided
File formats video
Non-radiometric (MPEG - encoded .AVI) and fully radiometric (.IS3)
Video recording
Standard and radiometric
Extensive memory options
Removable micro SD memory card, on-board flash memory, save-to-USB capability, direct download via USB-to-PC connection
Image capture, review, save mechanism
One-handed image capture, review, and save capability
Export file formats with SmartView® software
BMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF, and TIFF
Memory review
Thumbnail view navigation and review selection

Battery

Power saving
User selectable sleep and power off modes
Battery life
Three hours continuous use per battery pack
Battery charge time
2.5 hours to full charge
Battery charging system
Two-bay battery charger or in-imager charging. Optional 12 V automotive charging adapter
AC operation
AC operation with included power supply (100 V AC to 240 V AC, 50/60 Hz)
Batteries (field-replaceable, rechargeable)
Two lithium ion smart battery packs with five-segment LED display to show charge level

Temperature Measurement

Accuracy
± 2 °C or 2 % (at 25 °C nominal, whichever is greater)
On-screen transmission correction
Yes
Temperature measurement range (not calibrated below -10 °C)
'-20 °C to +1200 °C (-4 °F to +2192 °F)
On-screen reflected background temperature compensation
Yes
On-screen emissivity correction
Yes (both value and table)

Color Palettes

Ultra Contrast™ palettes
8: Ironbow Ultra, Blue-Red Ultra, High Contrast Ultra, Amber Ultra, Amber Inverted Ultra, Hot Metal Ultra, Grayscale Ultra, Grayscale Inverted Ultra
Standard palettes
8: Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted

General Specifications

Safety
IEC 61010-1: Overvoltage Category II, Pollution degree 2
User-definable spot markers
3 user-definable spot markers
Infrared spectral band
7.5 μm to 14 μm (long wave)
Weight (battery included)
1.5 kg (3.3 lb)
Center-point temperature measurement
Yes
Spot temperature
Hot and cold spot markers
Storage temperature
-20 °C to +50 °C (-4 °F to 122 °F) without batteries
Relative humidity
10 % to 95 % non-condensing
Drop
Engineered to withstand 1 meter (3.4 feet) drop with standard lens
Vibration
0.03 g2/Hz (3.8 grms), 2.5g IEC 68-2-6
Australian RCM
IEC/61326-1
US FCC
CFR 47, Part 15 Subpart B
Shock
25 g, IEC 68-2-29
Supported languages
Coming soon via firmware upgrade
Electromagnetic compatibility
IEC 61326-1: Basic EM Environment CISPR11, Group 1, Class A
Enclosure rating
IP54 (protected against dust, limited ingress; protection against water spray from all directions)
Warranty
Two-years (standard), extended warranties are available
Size (H x W x L)
27.3 cm x 15.9 cm x 9.7 cm (10.8 in x 6.3 in x 3.8 in)
Center box
Expandable-contractible measurement box with MIN-MAX-AVG temp
Recommended calibration cycle
Two-years (assumes normal operation and normal aging)
Operating temperature
-10 °C to +50 °C (14 °F to 122 °F)
Color alarms (temperature alarms)
High-temperature and low-temperature
Supported languages
Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish