Specifications
- Application
- Controls one boiler and one mixing (either variable speed injection or floating valve mixing) loop in a hydronic zoning system.
- Dimensions (in.)
- 16 1/2 in wide x 8 in. high x 3 3/8 in deep
- Dimensions (mm)
- 42 cm wide x 20.3 cm high x 8.5 cm deep
- Weight (lb)
- 6.0 lbs
- Weight (kg)
- 2.7 kg
- Approvals, Canadian Standards Association
- CSA C/US Certified to CSA and UL Standards, File No. LR76030
- Tradeline Value
- Tradeline
- Thermostat Compatibility
- AQ1000 Series 2-wire communicating thermostats and most digital thermostats
- Setback Program
- 7 day, up to 2 setback periods/day.
- User Interface
- LCD Display and a 7 button Key Pad
- Number of Zones
- 4
- Zoning Devices Controlled
- Zone pumps or 2-wire valves (line voltage)
- Boiler Control Temperature (F)
- Supply--Max: OFF, 120F to 225 F; Min: OFF, 59F to 180F; Differential--2 F to 41 F or Auto (minimum 2 minutes on time)
- Boiler Control Temperature (C)
- Supply--Max: OFF, 49C to 107 C; Min: OFF, 15C to 82C; Differential--1 C to 23 C or Auto (minimum 2 minutes on time)
- Boiler Design Temperature (F)
- 80F to 210F
- Boiler Design Temperature (C)
- 26C to 99C
- Outdoor Low Design Control Temperature (F)
- -60F to 32F
- Outdoor Low Design Control Temperature (C)
- -51 C to 0 C
- Return Min. Control Temperature (F)
- 80 F to 180 F
- Return Min. Control Temperature (C)
- 27C to 82C
- Boiler Heat Post Purge
- Off, 10 seconds to 30 minutes (factory default is 30 seconds)
- Pump/Valve exercise
- 30 seconds per 2 weeks of space heating inactivity
- R-C Output (on transformer)
- 38 VA, 24 Vac Class II
- R-C Input (on Control and Zoning Modules)
- 24 Vac Class II (input on Control and Zoning Modules)
- Demand Input
- Heat Demand (Thermostat R-W), Auxiliary Demand, and DHW Demand--External dry contacts connection only
- B-B Communication Bus Terminals
- Low voltage, Class II, 2-wire polarity-insensitive, digital communicating link to other Control or Zoning modules.
- Zone Module Thermostat Input
- Low voltage, Class II, 2-wire polarity-insensitive, digital communicating with power link to AQ1000 series thermostat.
- Output Ratings
- Boiler (T-T)-- 24 Vac, 0.5A, 12VA; Auxiliary Low Voltage-- 24 Vac, 0.5A, 12VA; Boiler Pump-- 120 Vac/250 Vac 5A, 1/3HP; DHW Pump/Valve-- 120 Vac 5A, 1/3HP; Auxiliary Pump-- Dry contact output, 120 Vac/250 Vac 5A, 1/3 HP
- Zone Output Contact Rating
- Pumps: 120 Vac/250 Vac, 5A, 1/3 HP,Valves: 24 Vac, 0.5 A, 12 VA
- Mixing Valve Floating Output (Com,O,C)
- 24 Vac rated dry contacts
- Mixing Valve Modulating Output
- 0-10 Vdc
- Secondary Pump Output Rating
- 120 Vac 5A, 1/3HP
- Variable Speed Injection Pump Output
- Triac modulated; 120 Vac, 2.1A, 1/6HP
- Electrical Connections
- Wire-clamp screw terminals, Maximum 2 x 14 AWG each on line voltage terminals
- Operating Humidity Range (% RH)
- 5 to 90% RH, non-condensing
- Secondary Loop Temperature Range (F)
- Mixing (Supply) max control--80 F to 210 F; Mixing (Supply) min control--35 F to 150 F; Mixing (Supply) Design Temperature--70 F to 210 F; Return min control--80 F to 180 F
- Secondary Loop Temperature Range (C)
- Mixing (Supply) max control--27 C to 99 C; Mixing (Supply) min control--2 C to 66 C; Mixing (Supply) Design Temperature--21 C to 99 C; Return min control--27 C to 82 C
- WWSD (Warm Weather Shut Down) Temperature (F)
- Off, 35 F to 100 F
- WWSD (Warm Weather Shut Down) Temperature (C)
- Off, 1 C to 38 C
- Sensor
- Supply/Return Sensor--10 kilohm NTC thermistor at 25 C (77 F) ±0.5F (±0.3C) up to 500 ft (150 M) using 18 AWG or larger wire, Lead Length: 10 ft. (3050 mm); Outdoor Sensor--10 kilohm NTC thermistor at 25 C (77 F) ± 0.5F (±0.3C) up to 500 ft (150 M) using
- Replacement Parts
- AQ10X38 24 Vac 38 VA transformer,AQ15540B 4-zone pump expansion module,AQ12C11 supply/return/mixed loop sensor,AQ12C10 outdoor sensor,AQ15200B universal injection/mixing boiler reset module
- Temperature Ratings (C)
- Panel--0 C to 55 C; Sensor-- -50 C to +110 C
- Temperature Ratings (F)
- Panel--32 F to 130 F; Sensor-- -58 F to +230 F
- Supply Voltage
- 120V 60 Hz
Documents
Data Sheet
DownloadOther Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther