Honeywell

VR8200A2082/B

24Vac dual standing pilot gas valve with standard opening
VR8200A2082/B
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Specifications

Application
Single Stage
Dimensions (in.)
5 3/16 in high x 4 1/8 in. wide x 3 1/4 in. deep
Dimensions (mm)
132 mm high x 104 mm wide x 83 mm deep
Item Type
Product
Mounting
0 to 90 degrees in any direction from the upright position of the gas control knob, including vertically.
Frequency
60 Hz
Approvals, Underwriters Laboratories Inc.
UL Component Recognized MCCZ2.MH5323
Approvals, Canadian Standards Association
CSA International: 112395
Electrical Connections
Combination screw and 1/4 in. male quick connects.
Voltage
24 Vac
Operating Temperature Range (F)
0 F to 175 F
Operating Temperature Range (C)
-18 C to +79 C
Body Pattern
Straight-through
Opening Characteristics
Standard Opening
Pressure Ratings (psi)
1/2 psi
Pressure Ratings (kPa)
3.5 kPa
Inlet/Outlet Size (in.)
1/2 in. x 1/2 in.
Pilot Gas Outlet
Compression fitting for 1/4 in. OD tubing
Pressure Tapping
1/8 in. NPT with plug
Type of Fuel
LP
Capacity (kBtuh)
At 1 in. wc p.d.-- 130,000 BTUh: 40,000 BTUh minimum
Approvals, Australian Gas Association
4717
Pressure Regulator Setpoint (in. wc)
10.0 in. wc
Pressure Regulator Setpoint (kPa)
2.49 kPa
Ignition Type
Standing Pilot
Anticipator Setting
0.5 A

Documents

Data Sheet

Download