VR8215S1503/U

Single Stage, 24 Vac, Standard Opening, Direct Ignition Gas Valve. 1/2 x 1/2". Set 3.5" WC
VR8215S1503/U
VR8215S1503/U
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up

Specifications

Application
Single Stage
Dimensions (in.)
3.38 inches high x 4.44 inches widex 2.70 inches deep
Dimensions (mm)
113 mm long x 86 inches high x 69 mm wide
Includes
Natural to LP Conversion Kit
Item Type
Product
Mounting
Multipoise - Mounts in any direction
Frequency
50, 60 Hz
Approvals, Canadian Standards Association
CSA International: 112395
Electrical Connections
1/4 in. quick-connect male terminals
Voltage
24 Vac
Operating Temperature Range (F)
-40 F to +175 F
Operating Temperature Range (C)
-40 C to +79 C
Body Pattern
Straight-through
Opening Characteristics
Standard Opening
Pressure Ratings (psi)
1/2 psi
Pressure Ratings (kPa)
3.5 kPa
Inlet/Outlet Size (in.)
1/2 in. x 1/2 in.
Pilot Gas Outlet
None
Pressure Tapping
1/8 in. NPT with plug
Type of Fuel
Natural (LP with included conversion kit)
Capacity (kBtuh)
At 1 in. wc p.d.-- 150,000 BTUh: 15,000 BTUh minimum: 200,000 BTUh maximum Natural Gas
Approvals, Australian Gas Association
7960
Pressure Regulator
Standard
Pressure Regulator Setpoint (in. wc)
3.5 in. wc
Pressure Regulator Setpoint (kPa)
0.87 kPa
Ignition Type
Direct Ignition

Related products