Specifications

Terminal Accommodations
#4 To #2 AWG copper wire only
Terminal Screws
Heat treated and Zinc Plated Steel
Current Interrupting
Certified for current interruption at full pated current.
Product Identification
Identification and ratings are a permanent part of the device housing.
Product Type
insulgrip-devices
Certification
UL Listed, UL Standard 1682, UL50 and UL1010 (plugs only), CSA Certified to CSA C22.2 No. 182.1, No.94 and No. 159 (plugs only), UL Listed and CSA Certified Type 4X.
Gaskets
Neoprene
Springs, Arm and Wave
Stainless Steel (300 series)
Voltage
250V DC/600V AC
Housing
Epoxy Painted Aluminum
Mounting Screws
Stainless Steel (300 Series)
Certifications
UL Listed, UL Standard 1682, UL 50, and UL 1010 (plugs only) CSA Certified to CSA Spec. C22.2 No. 182.1, No. 94 and No. 159 (plugs only) UL Listed, CSA Certified Type 4X.
Cord Accommodation
Round portable service cords of diameters commensurate with the device rating as defined in UL Standard 62, CSA C22.2 No. 49 and the harmonized European Standards.
Contact Carrier
Thermoset Polyester
Service Style
Reversed
Flammability
UL 94V-0 and CSA C22.2 No.0.17
Arm Spring
Stainless Steel (300 series)
Ground Bracket
Steel
Cover Screw/Rivet
Aluminum
Assembly Screws
Stainless Steel (300 series)
Mounting Flange
Epoxy Painted Aluminum
Weight in LBs
3.1
Amperage
100A
Endurance
Up to 1,000 connect and disconnect cycles at full rated current and voltage.
Max Working Voltage
600V AC RMS (i.e., minimum creepage and clearance distance of 6.4 mm, per UL 1682).
Dielectric Withstand Voltage
Withstands 3,000V AC Min.
Device
Receptacle
Temperature Rise
Max 30° C temperature rise at full rated current after 50 cycles of overload at 150% of rated current.
Cover Arm
Epoxy Painted Aluminum
Insulgrip Grounding Style
Style II
Operating Temperatures
Maximum Continuous: 75° C; Minimum Continuous: -40° C w/o impact, -25° with impact.
Ground Standoff
Brass
Ground/Phase Sleeve
Brass
Spring Guide
Stainless Steel (300 series)
Impact Resistance
Per CSA C22.2 N0. 182.1 / UL1682
Spring Washer
Stainless Steel (300 series)
Moisture Resistance
Type 3, 4, 4X per UL 50 and CSA C22.2, No. 94.
Cover
Epoxy Painted Aluminum
Replacement Interior Number
IN3100MS2
Hinge Bushing
Aluminum
Poles and Wires
2 Pole, 3 Wire
Terminal Identification
Terminals identified in accordance with UL1686 (1, 2, 3, Green).
Cord Grip Retention
Per CSA C22.2 N0. 182.1 / UL1682
Retainer
Thermoset Polyester