Specifications

Contact Carrier
High-Impact Thermoset
Amperage
60A
Housing
Zytel 801 Nylon
Weight in LBs
2.2
Operating Temperatures
Maximum Continuous: 75° C; Minimum Continuous: -40° C w/o impact.
Gland Cap
Rynite SST35
Certification
UL Listed, File E146032 Receptacles and Inlets, E146033 Plugs and Connectors, UL Standard UL1682 & UL1686C2, CSA Certified File LR280C for Plugs, Connectors and Inlets, LR285C for Receptacles, CSA Standard C22.2 No. 182.1, UL Classified to IEC60309-1, IEC
Color
blue
Retainer
High-Impact Thermoset
Product Identification
Identification and ratings are a permanent part of the device housing.
Assembly Screws
Stainless Steel (300 series)
Lock Ring
Rynite SST35
IEC Product Type
Watertight
Flammability
HB or Better per UL 94 or CSA C22.2 No. 0.17
Current Interrupting
Certified for current interrupting at full rated current.
Device
Plug
Terminal Accommodations
#8 To #2 AWG copper wire only
Impact Resistance
Per CSA C22.2 No. 182.1 / UL1682.
Clamp Nut
Nickel Plated Brass
Certifications
UL Listed, File E146032 Receptacles and Inlets, E146033 Plugs and Connectors, UL Standard UL1682 & UL 1686C2, CSA Certified File LR280C for Plugs, Connectors and Inlets and LR285C for Receptacle CSA Standard C22.2 No. 182.2, UL Classified to IEC 309-1 and
Terminal Screws
Stainless Steel (300 series)
Cord Accommodation
Round portable service cords of diameters commensurate with the device rating as defined in UL Standard 62, CSA C22.2 No. 49 and the harmonized European Standards.
Cord clamp range
.500" To 1.450"
Terminal Identification
Terminals identified in accordance with North American and IEC conventions.
Ingress Protection
IP 67 Suitability
Voltage
250V
Cord Clamp Screws
Stainless Steel (300 Series)
Temperature Rise
Max 30° C temperature rise at full rated current after 50 cycles of overload at 150% of rated current at a power factor of 75%.
Poles and Wires
2 Pole, 3 Wire
Cord Grip Retention
Per CSA C22.2 No. 182.1 / UL1682.
Endurance
5,000 connect and disconnect cycles with load for 16A and 20A, 1,000 cycles with load and 1,000 cycles w/o load for 30A, 32A, 60A and 63A, and 250 cycles with load and 250 cycles w/o load for 100A and 125A.
Cord Clamps
Rynite SST35
Max Working Voltage
600V RMS (i.e.minimum creepage distance 10 mm minimum)
Grommet/Glands
Solid Neoprene
Moisture Resistance
Watertight per IEC 60309-1
Service Style
Standard
Replacement Interior Number
IN360BM
Dielectric Withstand Voltage
Withstands 3,000V AC Min.
Ground/Phase Pins
Brass
Product Type
iec-devices