Hubbell Wiring Device-Kellems
HBL4100MI5W
This device provides on/off switched control of a plug connected load and includes an interlocking feature to prevent the plug from being disconnected while the receptacle is energized. The switch cannot be turned "ON" until the plug is inserted properly.
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Specifications
- Operating Temperatures
- Maximum Continuous: 75° C; Minimum Continuous: -40° C w/o impact.
- UV Resistance
- All materials are UV Stabilized.
- Horsepower Rating
- 50
- Service Style
- Standard
- Mechanical Interlock Device Standard
- IEC
- Top
- VALOX
- Shaft Seal
- Neoprene
- Max Working Voltage
- 600V AC RMS
- Base
- VALOX
- Amperage
- 100A
- Voltage
- 3 Phase 600V
- Gaskets
- Neoprene
- Current Interrupting
- Certified for current interrupting at full rated current.
- Enclosure Inserts
- Brass
- Flammability
- UL94-5VA and V-0 classification.
- Color
- black
- Shaft
- VALOX
- Assembly Screws
- Stainless Steel (300 series)
- Terminal Accommodations
- #2 To #10 AWG copper wire only
- Product Identification
- Identification and ratings are a part of the external label and molded into the receptacle mount.
- Ingress Protection
- IP67 Suitability
- Handle
- Valox
- Short Circuit Withstand
- Suitable for use on a circuit capable of delivering not more than 10,000 RMS symmetrical amperes at the voltage rating of the receptacle.
- Impact Resistance
- In accordance with UL746C
- Moisture Resistance
- Outdoor: 4X (Watertight, Washdown) Indoor: Type 12 (Dusttight, Falling Dirt and Non-Corrosive Liquids).
- Conduit Hub
- Zinc, Watertight
- Certifications
- UL Listed, CSA Certified.
- Weight in LBs
- 10
- Enclosure Hinge Pins
- Nickel Plated Brass
- Product Type
- mechanical-interlock
- Poles and Wires
- 3 Pole, 4 Wire
- Certification
- UL Listed, CSA Certified
- Dielectric Withstand Voltage
- Withstands 3,000V AC Min.
- Hinge Spring
- Stainless Steel (300 series)
- Terminal Identification
- Terminals identified in accordance with North American and International conventions.
- Endurance
- Mechanical: 10,000 cycles, Electrical: 6,000 cycles.
- Mechanical Interlock Items
- Complete Unit
Other Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther