2-Pole 3-Wire Grounding, 15A, 125V, 5-15R, Display Type, Brown Phenolic, with .060" Brass Plate and Blank Flush Plug.
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Specifications
- Product Type
- Specialty-receptacles
- Color
- Brown
- Receptacle Style
- Single
- Face Shape
- Traditional
- Standard
- NEMA
- Amperage
- 15A
- Voltage
- 125V
- Poles and Wires
- 2 Pole, 3-Wire Grounding
- Wiring Method
- Back Wired
- Hospital Grade ?
- No
- Specialty Type
- Display
- Plate Style
- With Brass Plate
- NEMA No.
- 5-15R
- Horsepower
- 0.5
- Type
- 2 Pole, 3 Wire, Grounding
- Rating
- 15A, 125V
- Certification
- UL Listed, File E2186, Listed to UL Standard 498
- Terminal Screw Material
- #8-32 Brass /Ni plated for neutral
- Ground Screw Material
- #8-32 Brass, Multiple Drive (Green)
- Top Material
- Phenolic
- Base Material
- Phenolic
- Power Contacts Material
- .032" (.81) Brass
- Mounting Screw Material
- Steel-Zinc Plated
- Dielectric Voltage
- Withstands 2,000V minimum.
- Current Interrupting
- Certified for current interrupting at full rated current.
- Temperature Rise
- Max 30°C temperature rise at full rated current after 50 cycles of overload at 150% of rated current at a power factor of 75%..
- Terminal Identification
- Terminals identified in accordance with UL498 (Brass, White, Green).
- Terminal Accommodation
- #14-#10 AWG copper stranded or solid conductor only.
- Product Identification
- Ratings are a permanent part of the device..
- Flammability
- UL 94 V2.
- Operating Temperatures
- Maximum continuous 75°C, minimum -40°C (w/o impact).
- Weight in LBs
- 0.550
Ordering Information
- Device Color
- Brown
Electrical
- Current Interrupting
- Certified for current interrupting at full rated current
- Dielectric Voltage
- Withstands 2,000V minimum
Mechanical
- Product Identification
- Ratings are a permanent part of the device
- Terminal Accommodation
- #14-#10 AWG copper stranded or solid conductor only
- Terminal Identification
- Terminals identified in accordance with UL 498 and CSA
Environmental
- Flammability
- UL 94 V-2 or better
- Operating Temperatures
- Maximum continuous 75°C; minimum -40°C (w/o impact)
Other Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther