Hubbell Wiring Device-Kellems
HBL560MI5W
This device provides on/off switched control of a plug connected load and includes an interlocking feature to prevent the plug from being disconnected while the receptacle is energized. The switch cannot be turned "ON" until the plug is inserted properly.
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Additional Information
- Part Number
- HBL560MI5W
- UPC
- 783585406152
- UNSPSC
- 39121406
- Country of Origin
- US
Specifications
- Product Identification
- Identification and ratings are a part of the external label and molded into the receptacle mount.
- Dielectric Withstand Voltage
- Withstands 3,000V AC
- Enclosure Inserts
- Brass
- Hinge Spring
- Stainless Steel (300 series)
- Current Interrupting
- Certified for current interrupting at full rated current.
- Voltage
- 3 Phase Y 347/600V
- Assembly Screws
- Stainless Steel (300 series)
- Flammability
- UL94-5VA and V-0 classification.
- Top
- VALOX
- Conduit Hub
- Zinc, Watertight
- Enclosure Hinge Pins
- Nickel Plated Brass
- Mechanical Interlock Device Standard
- IEC
- Certification
- UL Listed, CSA Certified
- Poles and Wires
- 4 Pole, 5 Wire
- Weight in LBs
- 8.65
- Product Type
- mechanical-interlock
- Handle
- Valox
- Certifications
- UL Listed, CSA Certified.
- Mechanical Interlock Items
- Complete Unit
- Endurance
- Mechanical: 10,000 cycles, Electrical: 6,000 cycles.
- UV Resistance
- All materials are UV Stabilized.
- Shaft Seal
- Neoprene
- Color
- black
- Horsepower Rating
- 40
- Terminal Accommodations
- #2 To #10 AWG copper wire only
- Moisture Resistance
- Outdoor: 4X (Watertight, Washdown) Indoor: Type 12 (Dusttight, Falling Dirt and Non-Corrosive Liquids).
- Gaskets
- Neoprene
- Impact Resistance
- In accordance with UL746C
- Ingress Protection
- IP67 Suitability
- Max Working Voltage
- 600V AC RMS
- Amperage
- 60A
- Service Style
- Standard
- Operating Temperatures
- Maximum Continuous: 75° C; Minimum Continuous: -40° C w/o impact.
- Terminal Identification
- Terminals identified in accordance with North American and International conventions.
- Shaft
- VALOX
- Base
- VALOX
- Short Circuit Withstand
- Suitable for use on a circuit capable of delivering not more than 10,000 RMS symmetrical amperes at the voltage rating of the receptacle.
Other Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther