40 A, Autovoltage General Purpose Time Control
GM40AV
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Specifications

Country of Origin
Mexico
Product Height
8 7/8 in; 22.56 mm
Product Width
6 39/64 in; 16.79 mm
Product Depth
3 in; 7.62 mm
Warranty Period
1-Year limited
Solutions
Refrigeration; Ventilation; Water Treatment; Generator Exercising
Packaging Applications
Lighting Control; Access Control; Commercial Refrigeration; General Electrical Circuits; Pumps; Motors; Fan Control
Minimum On Off Time
15 min
Maximum On Off Operations
48
Tungsten NO Load Ratings
15 A, 120 VAC
UL Certification
cULus
Other Certifications
cRUus
Operation Mode
24 hour
Operating Humidity
0-95% RH, Non-condensing
UL Cerfication File Number
#E10694
Patent Number
#6, 563, 237
Voltage Selection Type
Auto Voltage
Applications
Refrigeration Merchandiser; Air Movement & Ventilation; Aeration; Septic Treatment; Generator Exercising
Motor NC Load Ratings
1 HP, 12 FLA, 30 LRA @120 VAC; 2 HP, 10 FLA, 30 LRA @240 VAC
Motor NO Load Ratings
1 HP, 16 FLA, 90 LRA @ 120 VAC; 2 HP, 12 FLA, 52 LRA @ 208-277 VAC
Wiring Option
Screw box lug
Input Voltage Ranges
Auto Voltage 120-277 VAC, 60 Hz
Wire Size Max
#8 AWG
Enclosure Type
Indoor/outdoor type 3R plastic
Operating Temperature Min
-40°C
Operating Temperature Max
131°C
Operating Temperature Min
-40°F
Operating Temperature Max
55°F
Mechanism Type
Electromechanical
Switch Type
DPDT
Lifecycle
Production
Electrical Life
50, 000 operations at full load
Pilot Duty Load Ratings Ranges
300 VA, 120-240 VAC
Unit Carton Description
EA-Each
Number Of Trippers Included
96
RoHS Certification
Yes
Has Captive Trippers CVL
Yes
Has Override Switch CVL
Yes
Has Realtime Clock Face CVL
Yes
Market
Commercial; Industrial
Units Per Pallet
348

Load Ratings

Resistive NC Load Ratings
30 A, 120 VAC, 60 Hz; 30 A, 208 VAC, 60 Hz; 30 A, 240 VAC, 60 Hz; 30 A, 277 VAC, 60Hz
Tungsten NC Load Ratings
2 A, 120 VAC
Resistive NO Load Ratings
40 A, 120-277 VAC
Pilot Duty NO Load Ratings
300 VA, 120 VAC; 300 VA, 208 VAC; 300 VA, 240 VAC
Motor Load Ratings NC Ranges
1 HP, 12 FLA, 30 LRA @ 120 VAC; 2 HP, 10 FLA, 30 LRA @ 240 VAC
Motor Load Ratings NO Ranges
1 HP, 16 FLA, 90 LRA @120 VAC; 2 HP, 12 FLA, 52 LRA @ 208-277 VAC
Magnetic Ballast Load Ratings NO Ranges
30 A, 120 VAC; 20 A, 277 VAC
Magnetic Ballast Load Ratings NC Ranges
10 A, 277 VAC
Resistive Load Ratings NO Ranges
40 A, 120-277 VAC
Resistive Load Ratings NC Ranges
30 A, 120-277 VAC
Pilot Duty Load Ratings NO Ranges
300 VA, 120-240 VAC

Documents

Data Sheet

Download

Related products