24-Hour Mechanical Time Switch, 208-277 VAC, 60Hz, SPST, Indoor/Outdoor Plastic Enclosure, 1 Hour Interval
T102P
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Specifications

Country of Origin
Mexico
Product Height
10 in; 254 mm
Product Width
6 1/2 in; 165.1 mm
Product Depth
4 in; 101.6 mm
Warranty Period
1-Year limited
Solutions
Machinery & Pumps; Panel Integrators
Packaging Applications
Indoor/Outdoor Lighting; Signs; Filters; Electric Fences; Fans; Conveyors; Pool Heaters; Blowers; Pumps
Minimum On Off Time
1 hour
Maximum On Off Operations
12
Skipper Wheel Operation Mode
Not Included
UL Certification
cULus
CSA Certification
cCSAus
Other Certifications
LED
Operation Mode
24 hour
UL Cerfication File Number
UL917
Applications
Timing/Scheduling ON/OFF; Indoor Lighting Control; Outdoor Lighting Control
Application Compatibilities
LED; HID
Wire Size Min
#14 AWG
Wiring Option
Terminals
Input Voltage Ranges
208-277 VAC, 60 Hz
Wire Size Max
#8 AWG
Number Of Circuits
1
Enclosure Type
Indoor/outdoor type 3R plastic
Operating Temperature Min
-40°C
Operating Temperature Max
130°C
Operating Temperature Min
-40°F
Operating Temperature Max
54°F
Switch Type
SPST
Lifecycle
Production
Power Consumption Max W
3 W
Pilot Duty Load Ratings Ranges
1000 VA, 120-277 VAC, 60 Hz
Unit Carton Description
EA-Each
Number Of Trippers Included
1 ON/1 OFF
Has Manual Override CVL
Yes
Market
Commercial; Industrial
Units Per Pallet
144

Load Ratings

Pilot Duty Load Ratings
1000 VA, 120 VAC, 60 Hz; 1000 VA, 208 VAC, 60 Hz; 1000 VA, 240 VAC, 60 Hz; 1000 VA, 277 VAC, 60 Hz
Electronic Ballast Load Ratings
16 A, 208 VAC; 16 A, 240 VAC; 16 A, 277 VAC
Electronic Ballast Load Ratings Ranges
16 A, 208-277 VAC
Tungsten Load Ratings
40 A, 120 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 240 VAC, 60 Hz; 40 A, 277 VAC, 60 Hz
Tungsten Load Ratings Ranges
40 A, 120-277 VAC, 60 Hz
Resistive Load Ratings
40 A, 277 VAC, 60 Hz; 40 A, 240 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 120 VAC, 60 Hz
Resistive Load Ratings Ranges
40 A, 120-277 VAC, 60 Hz
Inductive Load Ratings
40 A, 277 VAC, 60 Hz; 40 A, 240 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 120 VAC, 60 Hz
Inductive Load Ratings Ranges
40 A, 120-277 VAC, 60 Hz
Motor Load Ratings
2 HP, 24 FLA @ 120 VAC, 60 Hz; 5 HP, 28 FLA @ 240 VAC, 60 Hz

Knockout

Knockout Dimensions Bottom
(2) combination 1/2" - 3/4"
Knockout Dimensions Back
(1) combination 1/2" - 3/4"

Related products