Omron D4MC-2000

Enclosed Switch

(21 offers)
Image of the product D4MC-2000
A total of  1111 Part In-Stock from 16 Distributors
New: 416 pcs. Used: 1 pcs. New Sealed: 694 pcs.
Standard sensitivity, IP67, Snap action, Self-reset mechanism, Single-Pole, Double-Throw type, SPDT, Hinge roller lever

Suppliers

In-Stock Parts

These parts are ready to be shipped immediately from warehouses across the world. Send inquiry for supplier details.
In Stock Updated 04/03/2024
  • Quantity: New: 377 pcs.
Register to See Company
Country: Germany
In Stock Updated 04/03/2024
  • Quantity: New Sealed: 78 pcs.
Register to See Company
Country: Czech Republic
In Stock Updated 04/03/2024
  • Quantity: New Sealed: 78 pcs.
Register to See Company
Country: Netherlands
In Stock Updated 04/03/2024
  • Quantity: New Sealed: 78 pcs.
In Stock Updated 04/03/2024
  • Quantity: New Sealed: 78 pcs.

On Request Parts

These parts are not in the warehouse and will be quoted with manufacturer lead time. Send inquiry for supplier details.
Register to See Company
Country: Germany
On Request Updated 04/03/2024
  • Quantity: New Sealed: 0 pcs.
On Request Updated 04/03/2024
  • Quantity: New Sealed: 0 pcs.
Register to See Company
Country: Portugal
On Request Updated 04/03/2024
  • Quantity: New Sealed: 0 pcs.
On Request Updated 04/03/2024
  • Quantity: New Sealed: 0 pcs.

Additional information

Part Number D4MC-2000

Ratings / Performance

Shape/Structure Enclosed Limit switches
Service life General type
Operating mechanism Snap action
Actuator Hinge roller lever
Frequency 50/60 Hz
Switching mechanism Self-reset mechanism
Contact configuration Single-Pole, Double-Throw type
Contact form SPDT
Load General load
Ratings (AC): Non-Inductive load Rated voltage: 125 VAC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 3 A(NC) 1.5 A(NO)
Ratings (AC): Non-Inductive load Rated voltage: 250 VAC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 2.5 A(NC) 1.25 A(NO)
Ratings (AC): Non-Inductive load Rated voltage: 480 VAC / Resistive load: 3 A(NC) 3 A(NO) / Lamp load: 1.5 A(NC) 0.75 A(NO)
Ratings (AC): Inductive load Rated voltage: 125 VAC / Inductive load: 10 A(NC) 10 A(NO) / Motor load: 5 A(NC) 2.5 A(NO)
Ratings (AC): Inductive load Rated voltage: 250 VAC / Inductive load: 10 A(NC) 10 A(NO) / Motor load: 3 A(NC) 1.5 A(NO)
Ratings (AC): Inductive load Rated voltage: 480 VAC / Inductive load: 2.5 A(NC) 2.5 A(NO) / Motor load: 1.5 A(NC) 0.75 A(NO)
Ratings (DC): Non-Inductive load Rated voltage: 8 VDC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 3 A(NC) 1.5 A(NO)
Ratings (DC): Non-Inductive load Rated voltage: 14 VDC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 3 A(NC) 1.5 A(NO)
Ratings (DC): Non-Inductive load Rated voltage: 30 VDC / Resistive load: 6 A(NC) 6 A(NO) / Lamp load: 3 A(NC) 1.5 A(NO)
Ratings (DC): Non-Inductive load Rated voltage: 125 VDC / Resistive load: 0.5 A(NC) 0.5 A(NO) / Lamp load: 0.4 A(NC) 0.4 A(NO)
Ratings (DC): Non-Inductive load Rated voltage: 250 VDC / Resistive load: 0.25 A(NC) 0.25 A(NO) / Lamp load: 0.2 A(NC) 0.2 A(NO)
Ratings (DC): Inductive load Rated voltage: 8 VDC / Inductive load: 6 A(NC) 6 A(NO) / Motor load: 5 A(NC) 2.5 A(NO)
Ratings (DC): Inductive load Rated voltage: 14 VDC / Inductive load: 6 A(NC) 6 A(NO) / Motor load: 5 A(NC) 2.5 A(NO)
Ratings (DC): Inductive load Rated voltage: 30 VDC / Inductive load: 5 A(NC) 5 A(NO) / Motor load: 5 A(NC) 2.5 A(NO)
Ratings (DC): Inductive load Rated voltage: 125 VDC / Inductive load: 0.05 A(NC) 0.05 A(NO) / Motor load: 0.05 A(NC) 0.05 A(NO)
Ratings (DC): Inductive load Rated voltage: 250 VDC / Inductive load: 0.03 A(NC) 0.03 A(NO) / Motor load: 0.03 A(NC) 0.03 A(NO)
Inrush current NC: 30 A
Inrush current NO: 15 A
Ambient temperature Operating: -10 to 80 °C
Ambient humidity Operating: 35 to 95%
Permissible operating speed 0.05 mm/s to 0.5 m/s
Permissible operating frequency (Mechanically) 120 operations / 1 minute Max.
Permissible operating frequency (Electrically) 20 operations / 1 minute Max.
Contact resistance 15 mOhm Max. (Initial value)
Contact resistance (Measuring method is contact resistance meter.)
Insulation resistance Between each terminal of the same polarities: 100 MΩ
Insulation resistance Between live-metallic part and ground: 100 MΩ
Insulation resistance Between each terminal and non-live-metallic part: 100 MΩ
Insulation resistance (at 500 VDC Megger)
Dielectric strength Between each terminal of the same polarities: 1000 V
Dielectric strength Between live-metallic part and ground: 2000 V
Dielectric strength Between each terminal and non-live-metallic part: 2000 V
Dielectric strength (50/60 Hz for 1 min)
Durability (Mechanically) 10,000,000 operations Min. (No load)
Durability (Mechanically) (Temperature, Humidity conditions: 20 +/- 2 CEL, 65 +/- 5 %RH)
Durability (Electrically) 500,000 operations Min. (Resistive load 10 A at 125 VAC) * When operate the actuator with the specified value of the Over Travel. (Resistive load 10 A at 125 VAC)
Durability (Electrically) (Temperature, Humidity conditions: 20 +/- 2 CEL, 65 +/- 5 %RH)
Vibration resistance (Malfunction) Vibration frequency range: 10 to 55 Hz, Double amplitude: 1.5 mm, Contact opening: 1 ms Max. at the free position and the total travel position.
Shock resistance (Destruction) 1,000 m/s2
Shock resistance (Malfunction) Contact opening is 1 ms Max. at the free position and the total travel position at 100 m/s2.
Degree of protection IEC60529 (JEM): IP67
Mounting specification Side mounting
Weight 88g
Operating Force (OF) Standard value Max. 1.96 N
Release Force (RF) Standard value Min. 0.39 N
Over-Travel (OT) Standard value 5 mm Min.
Movement Differential (MD) Standard value 3 mm Max.
Operating Position (OP) Standard value 40 +/- 1 mm
Free Position (FP) Standard value 51 mm Max.