Omron H5L-A

Daily Time Switch

(7 offers)
Image of the product H5L-A
A total of  11 Part In-Stock from 6 Distributors
New: 6 pcs. New Opened: 2 pcs. Refurbished: 1 pcs. New Surplus: 2 pcs.
Weekly Control with a Large Time Display

Suppliers

In-Stock Parts

These parts are ready to be shipped immediately from warehouses across the world. Send inquiry for supplier details.
Register to See Company
Country: United Kingdom
In Stock Updated 04/03/2024
  • Quantity: New: 3 pcs.
Register to See Company
Country: United Kingdom
In Stock Updated 04/03/2024
  • Quantity: New Opened: 2 pcs.
In Stock Updated 04/03/2024
  • Quantity: Refurbished: 1 pcs. New: 1 pcs.
Register to See Company
Country: United Kingdom
In Stock Updated 04/03/2024
  • Quantity: New Surplus: 2 pcs.
Register to See Company
Country: Germany
In Stock Updated 04/03/2024
  • Quantity: New: 1 pcs.

Additional information

Part Number H5L-A

Characteristics

Accuracy of operating time ±0.01% ±0.05 s max. *
Time accuracy ±15 s per month (at 25°C)
Insulation resistance 100 MΩ min.
Dielectric strength 2,000 VAC, 50/60 Hz for 1 min (between current-carrying terminals and exposed non-current-carrying metal parts and between control power supply circuit and contact control output circuits)
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts)
Vibration resistance Destruction: 10 to 55 Hz with 0.75-mm double amplitude
Vibration resistance Malfunction: 10 to 55 Hz with 0.5-mm double amplitude
Shock resistance Destruction: 300 m/s2 (approx. 30G)
Shock resistance Malfunction: 100 m/s2 (approx. 10G)
Ambient temperature Operating: -10°C to 55°C
Ambient humidity Operating: 35% to 85%
Life expectancy 100,000 operations min. (15 A at 250 VAC, resistive load)
Approved standards UL (File No. E52800), CSA (File No. LR22310)
Weight Approx. 350 g

Ratings

Rated supply voltage 100 to 240 VAC (50/60 Hz)
Operating voltage range 85% to 110% of rated supply voltage
Power consumption Approx. 4 VA at 240 VAC
Control outputs 15 A at 250 VAC, resistive load at 50°C
Control outputs 12 A at 250 VAC, resistive load at 55°C
Control outputs Minimum applied load: 100 mA at 5 VDC (failure level: P, reference value)

Lineup

Wiring Screw terminals
Backup power supply function for memory protection Provided (approx. 10 years at 25°C)
No. of program steps 24 (Each ON or OFF is considered to be one step.)
Model H5L-A

Time Ranges

Rated time 24 hrs x 7 days
Time setting range 00:00 to 23:59
Time division 1 min