Ratings / Performance

Function
Time Counter
Time counter (Input modes)
Quadrature
Time counter (Time ranges)
0 s to 999 h 59 min 59 s / 0.0 min to 9999 h 59.9 min (selectable)
Time counter (Set value read selector)
+/- 100 ppm (25 CEL)
Time counter (Minimum signal input width)
1 s
Time counter (Reset system)
External reset/manual reset
Input signal
Count input / Reset
Input method
Free voltage input
No-voltage input (No-contact input)
Short-circuit (ON) impedance: 10 kΩ
No-voltage input (No-contact input)
Residual voltage: 0.5 V max. (Actual performance 1.0 V)
No-voltage input (No-contact input)
Open circuit impedance: 750 kΩ
Voltage input
Hight level: 24 to 240 VAC/VDC
Voltage input
Low level: 0 to 2.4 VAC/VDC
Voltage input
Input resistance: 4.7 kΩ
Minimum input signal width
External reset: 20 ms
Display method
7-segment transmissive LCD
Digits
7digits
Character height
Current time: 8.6 mm (Black)
Character height
Zero suppression: Equipped
Prescaling function
Not provided
Key protection
Key protect Switch
Teaching function
Not provided
Batch counting function
Not provided
Communications
Not provided
Memory backup
Lithium battery ()
Battery life
For 10 years min. (with continuous input at 25CEL)
Surrounding air temperature
Operating: -10 to +55 °C
Surrounding air temperature
Storage: -25 to +65 °C
Ambient humidity
Operating: 25 to 85%
Ambient humidity
Storage: 25 to 85%
Insulation resistance
100 MΩ min. (at 500 VDC)
Insulation resistance
Between current-carrying terminals and exposed non-current-carrying metal parts / Between timer input terminals and reset terminals
Dielectric withstand voltage
Between timer input terminals and exposed non-current-carrying metal parts:3700 VAC 50/60 Hz for 1 min
Dielectric withstand voltage
Between reset terminals and exposed non-current-carrying metal parts:2200 VAC 50/60 Hz for 1 min
Dielectric withstand voltage
Between timer input terminals and reset terminals:2200 VAC 50/60 Hz for 1 min
Impulse withstand voltage
Between current-carrying terminal and exposed non-current -carrying metal parts:4.5 kV
Impulse withstand voltage
Between timer input terminals and reset terminals:3.0 kV
Noise immunity
Between timer input terminals:+/- 1.5k V
Noise immunity
Between reset terminals:+/- 500 V
Noise immunity
Square-wave noise by noise simulator (Pulse width: 100 ns/1 us, 1-ns rise)
Static immunity
8 kV (malfunction)
Vibration resistance (Destruction)
10 to 55 Hz with 0.375 mm single amplitude for two hours each in three directions
Vibration resistance (Malfunction)
10 to 55 Hz with 0.15 mm single amplitude for ten minutes each in three directions
Shock resistance (Destruction)
300 m/s**2 three times each in six directions
Shock resistance (Malfunction)
200 m/s**2 three times each in six directions
Degree of protection
Case front: IP66, NEMA 4 (indoors), and UL Type 4X (indoors)(when using the Y92S-32 Waterproof Packing and Y92F-30 Flush Mounting Adapter)
Degree of protection
Terminal block: IP20
Mounting method
Flush mounting
External connection method
Screw terminals
Case color
Black (Munsell N1.5)
Accessories
Flush mounting adapter / Waterproof rubber packing / Shock Prevention Cover / Unit label
Weight
Approx. 60 g

Documents

Data Sheet

Download