Request a Quote and we will send you information on availability and price.

General Information

Application Code
III
Lamp Type
PL-T/C
Number of Lamps
2 piece/unit
Number of Products on MCB (16A Type B) (Nom)
28
Automatic Restart
Yes

Operating and Electrical

Input Voltage
220 to 240 V
Input Frequency
50 to 60 Hz
Operating Frequency (Max)
kHz
Operating Frequency (Min)
42 kHz
Operating Frequency (Nom)
45 kHz
Ignition Method
Warm Start
Crestfactor (Max)
1.7
Power Factor 100% Load (Nom)
0.95
Ignition Time (Max)
0.40 s
Mains Voltage Performance (AC)
-8%-+6%
Mains Voltage Safety (AC)
-10%-+10%
Earth Leakage Current (Nom)
0.5 mA
Inrush Current Width
0.250 ms
Constant Wattage Deviation
-2%/+2%
Ballast Factor (Nom)
1
Power Losses (Nom)
0.68-2.21 W
Inrush Current Peak (Max)
18 A

Wiring

Connector Type Input Terminals
Insert
Cable Capacity Output Wires Mutual (Nom)
100 pF
Connector Type Output Terminals
Insert
Cable Length From Device to Lamp
1 m
Cable Length Hot Wiring
1 m
Wire Striplength
8.5-9.5 mm
Dual Fixture Master/Slave
Not applicable  [ Master/Slave oper. not applicable]
Input Terminal Cross Section
0.50-1.50 mm²
Output Terminal Cross Section
0.50-1.50 mm²
Cable Capacity Output Wires to Earth (Nom)
100 pF

System characteristics

Rated Ballast-Lamp Power
18 W
Rated Lamp Power on PL-T/C
2x18/18 W
System Power on PL-T/C
33.84/17.9 W
Power Loss on PL-T/C
2.64/1.9 W
Lamp Power on PL-T/C
31.2/16 W

Temperature

T-Ambient (Max)
50 °C
T-Ambient (Min)
-25 °C
T-Storage (Max)
80 °C
T-Storage (Min)
-40 °C
T-Case Lifetime (Nom)
75 °C
T-Case Maximum (Max)
75 °C
T-Ignition (Max)
50 °C
T-Ignition (Min)
-25 °C

Mechanical and Housing

Housing
S 103x67x30

Emergency Operation

Nominal Light Output After 60 Seconds
100% of EBLF
Battery Voltage Lamp Ignition
198-254 V
Normal Operating Voltage (DC)
220-240 V
Battery Voltage Lamp Operation
176-254
Battery Voltage Guaranteed Operation
176-275 V
Battery Voltage Guaranteed Ignition
186-275 V
Nominal Light Output After 5 Seconds
50% of EBLF

Approval and Application

Energy Efficiency Index
A2 BAT
IP Classification
IP 20  [ Ingress Protection 20]
EMI 9 kHz ... 30 MHz
EN55015
Safety Standard
IEC 61347-2-3
Performance Standard
IEC 60929
Quality Standard
ISO 9000:2000
Environmental Standard
ISO 14001
Harmonic Current Emission Standard
IEC 61000-3-2
EMC Immunity Standard
IEC 61547
Vibration Standard
IEC68-2-6 F c
Bumps Standard
IEC 68-2-29 Eb
Humidity Standard
EN 61347-2-3 clause 11
Temperature Marking
Yes
Emergency Standard
IEC 60598-2-22
Hum And Noise Level
Inaudible

Product Data

Full product code
872790083417800
Order product name
HF-P 1/218 PL-T/C III 220-240V
EAN/UPC - Product
8711500881038
Order code
913700648666
Numerator - Quantity Per Pack
1
Numerator - Packs per outer box
12
Material Nr. (12NC)
913700648666
Net Weight (Piece)
0.130 kg

Documents

Data Sheet

Download