Electronic device circuit breaker - CBMC E4 24DC/1-4A+ NO-C - 1021728
1021728
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Remote indication contact

Connection name
Remote indication circuit
Switching function
N/O contact
Stripping length
10 mm
Conductor cross section solid
0.2 mm² - 2.5 mm²
Conductor cross section AWG
24 - 12
Conductor cross section, flexible, with ferrule, with plastic sleeve
0.25 mm² - 1.5 mm²
Conductor cross section flexible, with ferrule without plastic sleeve
0.25 mm² - 2.5 mm²
DC operating voltage
0 V DC - 30 V DC
DC operating current
100 mA DC

Electrical data

Fuse type
electronic
Rated surge voltage
0.5 kV
Operating voltage
18 V DC - 30 V DC
Rated voltage
24 V DC
Rated current IN
max. 16 A DC (IN+)
Rated current IN
max. 40 A DC (per terminal position when bridging additional devices via IN+)
Rated current IN
1 / 2 / 3 / 4 A DC (adjustable or fixed per output channel)
Measuring tolerance I
± 15 %
Feedback resistance
max. 35 V DC
Fail-safe element
15 A DC (per output channel)
Efficiency
> 99 %
Closed circuit current I0
typ. 33 mA
Power dissipation
typ. 0.8 W (No-load operation)
Power dissipation
< 2 W (Nominal operation)
Module initialization time
1.6 s
Waiting time after switch off of a channel
5 s (at overload / short circuit)
Tripping method
E (electronic)
Required backup fuse
not required, integrated failsafe element
Dielectric strength
max. 35 V DC (Load circuit)
MTBF (IEC 61709, SN 29500)
11764705 h (at 25°C with 21% load)
MTBF (IEC 61709, SN 29500)
5319148 h (at 40°C with 34.25% load)
MTBF (IEC 61709, SN 29500)
846023 h (at 60°C with 100% load)
Shutdown time load circuit
≤ 10 ms (for short circuit > 2.0 x IN)
Shutdown time load circuit
1 s (1.2 - 2.0 x IN)
Undervoltage shutdown load circuit
≤ 17.8 V DC (active)
Undervoltage shutdown load circuit
≥ 18.8 V DC (inactive)
Surge voltage shutdown load circuit
≥ 30.5 V DC (active)
Surge voltage shutdown load circuit
≤ 29.5 V DC (inactive)
Max. capacitive load load circuit
30000 µF (Depending on the current setting and the short-circuit current available)

Dimensions

Height
90 mm
Width
36 mm
Depth
98 mm (incl. DIN rail 7.5 mm)

Connection data

Connection name
Main circuit IN+
Connection method
Push-in connection
Stripping length
15 mm
Conductor cross section solid
0.2 mm² - 10 mm²
Conductor cross section AWG
24 - 8
Conductor cross section, flexible, with ferrule, with plastic sleeve
0.25 mm² - 4 mm²
Conductor cross section flexible, with ferrule without plastic sleeve
0.25 mm² - 6 mm²
Connection name
Main circuit IN-
Stripping length
10 mm
Conductor cross section solid
0.2 mm² - 2.5 mm²
Conductor cross section AWG
24 - 12
Conductor cross section, flexible, with ferrule, with plastic sleeve
0.25 mm² - 1.5 mm²
Connection name
Main circuit OUT
Conductor cross section flexible, with ferrule without plastic sleeve
0.25 mm² - 2.5 mm²

Ambient conditions

Ambient temperature (operation)
-25 °C - 60 °C
Ambient temperature (storage/transport)
-40 °C - 80 °C
Humidity test
240 h, 95 % RH, 40 °C
Altitude
≤ 3000 m up to 52 °C (amsl (above mean sea level))
Altitude
≤ 4000 m up to 46 °C (amsl (above mean sea level))
Shock (operation)
30g (IEC 60068-2-27, Test Ea)
Vibration (operation)
10 Hz - 57.6 Hz (Amplitude ±0.35 mm; in accordance with IEC 60068-2-6, Test Fc)
Vibration (operation)
57.6 Hz … 150 Hz (Acceleration 5g; in accordance with IEC 60068-2-6, Test Fc)
Degree of protection
IP20

Environmental Product Compliance

REACh SVHC
Lead 7439-92-1
China RoHS
Environmentally Friendly Use Period = 50 years
China RoHS
For details about hazardous substances go to tab 'Downloads', Category 'Manufacturer's declaration'

Signaling

Channel LED off
off (Channel switched off)
Channel LED green
lit (Channel switched on)
Channel LED yellow
lit (Channel switched on, channel load > 80% )
Channel LED yellow
flashing (Programming mode active)
Channel LED red
lit (Channel switched off, over- or undervoltage active)
Channel LED red
ON temporarily (Channel switched off, 5 s cool-down phase, overload or short-circuit release)
Channel LED red
flashing (Channel switched off, ready to be switched back on, overload or short-circuit release)
Channel LED red
two flashes (Channel switched off, device total current limit 40 A exceeded)

Standards and Regulations

Standards/specifications
EN 61000-6-2 EMC – Immunity for industrial areas
Standards/specifications
EN 61000-6-3 EMC – Emission for residential, business and commercial properties and small operations
Standards/specifications
EN 60068-2-6 Environmental influences – Vibrations (sinusoidal)
Standards/specifications
EN 60068-2-27 Environmental influences – Shocks
Standards/specifications
EN 60068-2-78 Environmental influences – Moisture and heat, constant
Standards/specifications
EN 50178 Equipping power installations with electronic equipment