Electronic device circuit breaker - CBMC E4 24DC/1-4A S-R-C - 1103876
1103876
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Electrical data

Fuse type
electronic
Rated surge voltage
0.5 kV
Operating voltage
18 V DC - 30 V DC
Rated voltage
24 V DC
Rated current IN
max. 16 A DC (IN+)
Rated current IN
max. 40 A DC (per terminal position when bridging additional devices via IN+)
Rated current IN
1 / 2 / 3 / 4 A DC (adjustable or fixed per output channel)
Measuring tolerance I
± 15 %
Feedback resistance
max. 35 V DC
Fail-safe element
4 A DC (per output channel)
Efficiency
> 99 %
Closed circuit current I0
typ. 33 mA
Power dissipation
typ. 0.8 W (No-load operation)
Power dissipation
< 4 W (Nominal operation)
Module initialization time
1.6 s
Waiting time after switch off of a channel
5 s (at overload / short circuit)
Tripping method
E (electronic)
Required backup fuse
not required, integrated failsafe element
Dielectric strength
max. 35 V DC (Load circuit)
MTBF (IEC 61709, SN 29500)
11764705 h (at 25°C with 21% load)
MTBF (IEC 61709, SN 29500)
5319148 h (at 40°C with 34.25% load)
MTBF (IEC 61709, SN 29500)
846023 h (at 60°C with 100% load)
Shutdown time load circuit
≤ 10 ms (for short circuit > 2.0 x IN)
Shutdown time load circuit
1 s (1.2 - 2.0 x IN)
Undervoltage shutdown load circuit
≤ 17.8 V DC (active)
Undervoltage shutdown load circuit
≥ 18.8 V DC (inactive)
Surge voltage shutdown load circuit
≥ 30.5 V DC (active)
Surge voltage shutdown load circuit
≤ 29.5 V DC (inactive)
Max. capacitive load load circuit
30000 µF (Depending on the current setting and the short-circuit current available)
Output voltage status output
24 V DC
Output current status output
max. 0.04 A (Short-circuit-proof)
Stripping length
10 mm
Conductor cross section solid
0.2 mm² - 2.5 mm²
Conductor cross section flexible, with ferrule without plastic sleeve
0.25 mm² - 2.5 mm²
Conductor cross section AWG
24 - 12
Input voltage reset input
7 V DC - 30 V DC (Reset with falling edge)
Current consumption reset input
typ. 0.4 mA (at 24 V DC)
Pulse length reset input
≥ 50 ms (High)
Pulse length reset input
≥ 50 ms (Low)
Voltage reset input
< 5 V DC (Low state)
Voltage reset input
> 8 V DC (High state)
Conductor cross section, flexible, with ferrule, with plastic sleeve
0.25 mm² - 1.5 mm²

Dimensions

Height
90 mm
Width
36 mm
Depth
98 mm (incl. DIN rail 7.5 mm)

Connection data

Connection name
Main circuit IN+
Connection method
Push-in connection
Stripping length
15 mm
Conductor cross section solid
0.2 mm² - 10 mm²
Conductor cross section AWG
24 - 8
Conductor cross section, flexible, with ferrule, with plastic sleeve
0.25 mm² - 4 mm²
Conductor cross section flexible, with ferrule without plastic sleeve
0.25 mm² - 6 mm²
Connection name
Main circuit IN-
Stripping length
10 mm
Conductor cross section solid
0.2 mm² - 2.5 mm²
Conductor cross section AWG
24 - 12
Conductor cross section flexible, with ferrule without plastic sleeve
0.25 mm² - 2.5 mm²
Connection name
Main circuit OUT+
Conductor cross section, flexible, with ferrule, with plastic sleeve
0.25 mm² - 1.5 mm²

Ambient conditions

Ambient temperature (operation)
-25 °C - 60 °C
Ambient temperature (storage/transport)
-40 °C - 70 °C
Humidity test
96 h, 95 % RH, 40 °C
Altitude
≤ 3000 m up to 52 °C (amsl (above mean sea level))
Altitude
≤ 4000 m up to 46 °C (amsl (above mean sea level))
Shock (operation)
30g (IEC 60068-2-27, Test Ea)
Vibration (operation)
10 Hz - 57.6 Hz (Amplitude ±0.35 mm; in accordance with IEC 60068-2-6, Test Fc)
Vibration (operation)
57.6 Hz … 150 Hz (Acceleration 5g; in accordance with IEC 60068-2-6, Test Fc)
Degree of protection
IP20

Environmental Product Compliance

REACh SVHC
Lead 7439-92-1

Signaling

Channel LED off
off (Channel switched off)
Channel LED green
lit (Channel switched on)
Channel LED yellow
lit (Channel switched on, channel load > 80% )
Channel LED yellow
flashing (Programming mode active)
Channel LED red
lit (Channel switched off, over- or undervoltage active)
Channel LED red
ON temporarily (Channel switched off, 5 s cool-down phase, overload or short-circuit release)
Channel LED red
flashing (Channel switched off, ready to be switched back on, overload or short-circuit release)
Channel LED red
two flashes (Channel switched off, device total current limit 40 A exceeded)

Standards and Regulations

Standards/specifications
EN 61000-6-2 EMC – Immunity for industrial areas
Standards/specifications
EN 61000-6-3 EMC – Emission for residential, business and commercial properties and small operations
Standards/specifications
EN 60068-2-6 Environmental influences – Vibrations (sinusoidal)
Standards/specifications
EN 60068-2-27 Environmental influences – Shocks
Standards/specifications
EN 60068-2-78 Environmental influences – Moisture and heat, constant
Standards/specifications
EN 50178 Equipping power installations with electronic equipment